Investigation of skin-deposited particulate matter from smelting operations via tape stripping and SEM-EDS.

IF 1.4 4区 医学 Q4 ENVIRONMENTAL SCIENCES
Rikke Bramming Jørgensen, Ida Teresia Kero, Sigurd Wenner, Marit Nøst Hegseth, Solveig Føreland
{"title":"Investigation of skin-deposited particulate matter from smelting operations via tape stripping and SEM-EDS.","authors":"Rikke Bramming Jørgensen, Ida Teresia Kero, Sigurd Wenner, Marit Nøst Hegseth, Solveig Føreland","doi":"10.1080/15459624.2025.2602756","DOIUrl":null,"url":null,"abstract":"<p><p>This study investigated the elemental composition and particle size of particulate matter (PM) deposited on the skin from industrial exposure during work in a ferro-silicon smelter using scanning electron microscopy (SEM) analysis combined with energy-dispersive X-ray spectroscopy (EDS). Tape stripping and interception sampling methods were trialed with different tape types. D-squame tape, together with the D-squame applicator instrument, was chosen because it represented a replicable and standardized method allowing SEM analyses to be performed, enabled analyses of deeper skin layers, and had no negative attributes compared to carbon tape when a protocol for imaging non-conductive specimens was used. The underside of the wrist was selected as the sampling site. The observed particle sizes varied from approximately 200 µm to 200 nm. The backscattered electron mode was best adapted to detect particles inside the stratum corneum (SC) due to all detected inorganic compounds giving stronger backscattering than skin. Elemental analysis was obtained by energy-dispersive X-ray spectroscopy. Using the results of 10 repetitive samples from the worker with the most PM exposure, the elemental concentration profiles for Si, Fe, and S in the SC were measured. The elemental concentration showed an exponential decrease during the first four strips, suggesting that most particle penetration is hindered by the first few layers of the SC.</p>","PeriodicalId":16599,"journal":{"name":"Journal of Occupational and Environmental Hygiene","volume":" ","pages":"286-301"},"PeriodicalIF":1.4000,"publicationDate":"2026-05-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Occupational and Environmental Hygiene","FirstCategoryId":"93","ListUrlMain":"https://doi.org/10.1080/15459624.2025.2602756","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2026/1/21 0:00:00","PubModel":"Epub","JCR":"Q4","JCRName":"ENVIRONMENTAL SCIENCES","Score":null,"Total":0}
引用次数: 0

Abstract

This study investigated the elemental composition and particle size of particulate matter (PM) deposited on the skin from industrial exposure during work in a ferro-silicon smelter using scanning electron microscopy (SEM) analysis combined with energy-dispersive X-ray spectroscopy (EDS). Tape stripping and interception sampling methods were trialed with different tape types. D-squame tape, together with the D-squame applicator instrument, was chosen because it represented a replicable and standardized method allowing SEM analyses to be performed, enabled analyses of deeper skin layers, and had no negative attributes compared to carbon tape when a protocol for imaging non-conductive specimens was used. The underside of the wrist was selected as the sampling site. The observed particle sizes varied from approximately 200 µm to 200 nm. The backscattered electron mode was best adapted to detect particles inside the stratum corneum (SC) due to all detected inorganic compounds giving stronger backscattering than skin. Elemental analysis was obtained by energy-dispersive X-ray spectroscopy. Using the results of 10 repetitive samples from the worker with the most PM exposure, the elemental concentration profiles for Si, Fe, and S in the SC were measured. The elemental concentration showed an exponential decrease during the first four strips, suggesting that most particle penetration is hindered by the first few layers of the SC.

利用胶带剥离和扫描电镜能谱仪研究冶炼过程中皮肤沉积的颗粒物质。
本研究利用扫描电子显微镜(SEM)和能量色散x射线光谱(EDS)相结合的方法,研究了硅铁冶炼厂工作期间工业暴露在皮肤上的颗粒物(PM)的元素组成和粒径。试验了不同类型胶带的剥离和拦截取样方法。选择D-squame胶带和D-squame涂抹器仪器,是因为它代表了一种可复制和标准化的方法,允许进行SEM分析,可以分析更深的皮肤层,并且在使用成像非导电标本的协议时,与碳胶带相比没有负面属性。选择腕部下侧作为采样部位。观察到的颗粒大小从大约200µm到200 nm不等。背散射电子模式最适合于检测角质层(SC)内的粒子,因为所有被检测的无机化合物都比皮肤具有更强的背散射。元素分析采用能量色散x射线光谱法。利用来自PM暴露最多的工人的10个重复样本的结果,测量了SC中Si, Fe和S的元素浓度分布。元素浓度在前四层呈指数下降,表明大多数颗粒的渗透被前几层SC阻碍。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
Journal of Occupational and Environmental Hygiene
Journal of Occupational and Environmental Hygiene 环境科学-公共卫生、环境卫生与职业卫生
CiteScore
3.30
自引率
10.00%
发文量
81
审稿时长
12-24 weeks
期刊介绍: The Journal of Occupational and Environmental Hygiene ( JOEH ) is a joint publication of the American Industrial Hygiene Association (AIHA®) and ACGIH®. The JOEH is a peer-reviewed journal devoted to enhancing the knowledge and practice of occupational and environmental hygiene and safety by widely disseminating research articles and applied studies of the highest quality. The JOEH provides a written medium for the communication of ideas, methods, processes, and research in core and emerging areas of occupational and environmental hygiene. Core domains include, but are not limited to: exposure assessment, control strategies, ergonomics, and risk analysis. Emerging domains include, but are not limited to: sensor technology, emergency preparedness and response, changing workforce, and management and analysis of "big" data.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信
小红书