Omar Bentiane, Omaima Khettabi, Omar Berradi, El Mehdi Sadiki, Fatimaezzahra Bouzzit, Rodouan Touti
{"title":"Beyond CTDIvol: Patient-specific SSDE and organ dose assessment in routine adult CT practice","authors":"Omar Bentiane, Omaima Khettabi, Omar Berradi, El Mehdi Sadiki, Fatimaezzahra Bouzzit, Rodouan Touti","doi":"10.1016/j.radphyschem.2026.113658","DOIUrl":null,"url":null,"abstract":"<div><div>Computed Tomography (CT) is a key diagnostic tool in medical imaging, but concerns persist regarding radiation exposure, particularly in repeat or high-dose examinations. The CTDI<sub>vol</sub> quantifies scanner output but does not accurately represent the patient dose. The Size-Specific Dose Estimate (SSDE) provides a more clinically relevant patient-specific dose estimate by accounting for body size and composition. This study aims to quantify the differences between CTDI<sub>vol</sub> and SSDE in adult thoraco-abdominopelvic and abdominopelvic CT scans, compare manual and automatic methods of patient size estimation, and evaluate organ doses. A retrospective review was conducted on 52 adult CT scans (thoraco-abdominopelvic and abdominopelvic). Four patient-size metrics were collected: the manually measured effective diameter (D<sub>eff-M</sub>), the automatically averaged z-axis effective diameter (D<sub>eff-AZ</sub>), and two water-equivalent diameters (D<sub>w-E</sub> and D<sub>w-AZ</sub>). The SSDE values were calculated according to AAPM TG-204 and TG-220. The organ doses were estimated with <em>IndoseCT</em> based on Monte Carlo-derived correlations. The mean CTDI<sub>vol</sub> was 13.0 ± 3.6 mGy, with SSDE values 31–37 % higher across all methods. D<sub>eff-AZ</sub> was 4.7 % greater than D<sub>eff-M</sub>, while D<sub>w-E</sub> and D<sub>w-AZ</sub> showed near-perfect agreement. The liver, kidneys, and bladder received the highest doses (>15 mGy) as they are directly irradiated, whereas radiosensitive organs outside the primary scan field, such as the thyroid and eyes, received measurable scatter doses. SSDE provides a more accurate representation of patient radiation dose than CTDI<sub>vol</sub> and should be integrated into routine CT protocols. Among the evaluated size metrics, attenuation-based D<sub>w</sub> proved to be the most robust and reproducible. Incorporating organ-dose estimations and SSDE into clinical practice can enhance patient safety, optimize imaging protocols, and support compliance with radiation protection regulations.</div></div>","PeriodicalId":20861,"journal":{"name":"Radiation Physics and Chemistry","volume":"243 ","pages":"Article 113658"},"PeriodicalIF":3.5000,"publicationDate":"2026-06-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Radiation Physics and Chemistry","FirstCategoryId":"92","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S0969806X2600068X","RegionNum":3,"RegionCategory":"物理与天体物理","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2026/1/21 0:00:00","PubModel":"Epub","JCR":"Q3","JCRName":"CHEMISTRY, PHYSICAL","Score":null,"Total":0}
引用次数: 0
Abstract
Computed Tomography (CT) is a key diagnostic tool in medical imaging, but concerns persist regarding radiation exposure, particularly in repeat or high-dose examinations. The CTDIvol quantifies scanner output but does not accurately represent the patient dose. The Size-Specific Dose Estimate (SSDE) provides a more clinically relevant patient-specific dose estimate by accounting for body size and composition. This study aims to quantify the differences between CTDIvol and SSDE in adult thoraco-abdominopelvic and abdominopelvic CT scans, compare manual and automatic methods of patient size estimation, and evaluate organ doses. A retrospective review was conducted on 52 adult CT scans (thoraco-abdominopelvic and abdominopelvic). Four patient-size metrics were collected: the manually measured effective diameter (Deff-M), the automatically averaged z-axis effective diameter (Deff-AZ), and two water-equivalent diameters (Dw-E and Dw-AZ). The SSDE values were calculated according to AAPM TG-204 and TG-220. The organ doses were estimated with IndoseCT based on Monte Carlo-derived correlations. The mean CTDIvol was 13.0 ± 3.6 mGy, with SSDE values 31–37 % higher across all methods. Deff-AZ was 4.7 % greater than Deff-M, while Dw-E and Dw-AZ showed near-perfect agreement. The liver, kidneys, and bladder received the highest doses (>15 mGy) as they are directly irradiated, whereas radiosensitive organs outside the primary scan field, such as the thyroid and eyes, received measurable scatter doses. SSDE provides a more accurate representation of patient radiation dose than CTDIvol and should be integrated into routine CT protocols. Among the evaluated size metrics, attenuation-based Dw proved to be the most robust and reproducible. Incorporating organ-dose estimations and SSDE into clinical practice can enhance patient safety, optimize imaging protocols, and support compliance with radiation protection regulations.
期刊介绍:
Radiation Physics and Chemistry is a multidisciplinary journal that provides a medium for publication of substantial and original papers, reviews, and short communications which focus on research and developments involving ionizing radiation in radiation physics, radiation chemistry and radiation processing.
The journal aims to publish papers with significance to an international audience, containing substantial novelty and scientific impact. The Editors reserve the rights to reject, with or without external review, papers that do not meet these criteria. This could include papers that are very similar to previous publications, only with changed target substrates, employed materials, analyzed sites and experimental methods, report results without presenting new insights and/or hypothesis testing, or do not focus on the radiation effects.