Resolution of intradialytic hypotension and changes in hepatic oxygenation following the transition from hemodialysis to intermittent infusion hemodiafiltration: a case report.

IF 1.2 4区 医学 Q4 ENGINEERING, BIOMEDICAL
Haruhisa Miyazawa, Kiyonori Ito, Yusaku Watanabe, Wataru Okamoto, Moeka Suzuki, Junki Morino, Yuko Mutsuyoshi, Taisuke Kitano, Jo Yoshizawa, Mamoru Yoshizawa, Susumu Ookawara
{"title":"Resolution of intradialytic hypotension and changes in hepatic oxygenation following the transition from hemodialysis to intermittent infusion hemodiafiltration: a case report.","authors":"Haruhisa Miyazawa, Kiyonori Ito, Yusaku Watanabe, Wataru Okamoto, Moeka Suzuki, Junki Morino, Yuko Mutsuyoshi, Taisuke Kitano, Jo Yoshizawa, Mamoru Yoshizawa, Susumu Ookawara","doi":"10.1007/s10047-025-01544-5","DOIUrl":null,"url":null,"abstract":"<p><p>An 82-year-old Japanese man had been undergoing hemodialysis (HD) for the preceding 5 months for chronic glomerulonephritis. During HD, the patient experienced recurrent episodes of intradialytic hypotension (IDH) resulting from an ultrafiltration-induced reduction in blood volume. Although we recommended an increase in dry weight to mitigate the onset of IDH, the patient declined this proposal. To maintain systemic hemodynamic stability during dialysis, the treatment modality was changed from HD to intermittent infusion hemodiafiltration (I-HDF). Relative changes in blood volume (%ΔBV) and hepatic regional oxygen saturation (rSO2) during both HD and I-HDF were continuously monitored using a Blood Volume Monitoring System (NIPRO Co., Osaka, Japan) and an INVOS 5100c oxygen saturation monitor (Covidien Japan, Tokyo, Japan), respectively. The decline in %ΔBV at the end of I-HDF was less pronounced than during HD (HD − 16.9%; I-HDF − 12.8%), and hepatic rSO2 remained stable during I-HDF, in contrast to the continuous decrease observed during HD. Moreover, no episode of IDH was observed in the I-HDF. Improved systemic hemodynamic stability observed during I-HDF may be attributable to the preservation of hepato-splanchnic circulation and oxygenation associated with cyclic dialysate infusion, although direct evidence for this association is still lacking.</p>","PeriodicalId":15177,"journal":{"name":"Journal of Artificial Organs","volume":"29 1","pages":"17"},"PeriodicalIF":1.2000,"publicationDate":"2026-01-20","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Artificial Organs","FirstCategoryId":"5","ListUrlMain":"https://doi.org/10.1007/s10047-025-01544-5","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"ENGINEERING, BIOMEDICAL","Score":null,"Total":0}
引用次数: 0

Abstract

An 82-year-old Japanese man had been undergoing hemodialysis (HD) for the preceding 5 months for chronic glomerulonephritis. During HD, the patient experienced recurrent episodes of intradialytic hypotension (IDH) resulting from an ultrafiltration-induced reduction in blood volume. Although we recommended an increase in dry weight to mitigate the onset of IDH, the patient declined this proposal. To maintain systemic hemodynamic stability during dialysis, the treatment modality was changed from HD to intermittent infusion hemodiafiltration (I-HDF). Relative changes in blood volume (%ΔBV) and hepatic regional oxygen saturation (rSO2) during both HD and I-HDF were continuously monitored using a Blood Volume Monitoring System (NIPRO Co., Osaka, Japan) and an INVOS 5100c oxygen saturation monitor (Covidien Japan, Tokyo, Japan), respectively. The decline in %ΔBV at the end of I-HDF was less pronounced than during HD (HD − 16.9%; I-HDF − 12.8%), and hepatic rSO2 remained stable during I-HDF, in contrast to the continuous decrease observed during HD. Moreover, no episode of IDH was observed in the I-HDF. Improved systemic hemodynamic stability observed during I-HDF may be attributable to the preservation of hepato-splanchnic circulation and oxygenation associated with cyclic dialysate infusion, although direct evidence for this association is still lacking.

从血液透析过渡到间歇输注血液滤过后透析性低血压的解决和肝氧合的变化:1例报告。
一名82岁日本男性因慢性肾小球肾炎接受血液透析(HD)治疗5个月。在HD期间,患者经历了反复发作的透析性低血压(IDH),这是由超滤引起的血容量减少引起的。虽然我们建议增加干重以减轻IDH的发病,但患者拒绝了这一建议。为了维持透析期间的全身血流动力学稳定性,治疗方式由HD改为间歇输注血液透析(I-HDF)。分别使用血容量监测系统(NIPRO Co.,大阪,日本)和INVOS 5100c血氧饱和度监测仪(Covidien Japan,东京,日本)连续监测HD和I-HDF期间血容量(%ΔBV)和肝脏区域血氧饱和度(rSO2)的相对变化。在I-HDF结束时,%ΔBV的下降不如HD期间明显(HD - 16.9%; I-HDF - 12.8%),并且在I-HDF期间肝脏rSO2保持稳定,与HD期间观察到的持续下降相反。此外,在I-HDF中未观察到IDH发作。在I-HDF期间观察到的改善的全身血流动力学稳定性可能归因于与循环透析液输注相关的肝-内脏循环和氧合的保存,尽管仍然缺乏这种关联的直接证据。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
Journal of Artificial Organs
Journal of Artificial Organs 医学-工程:生物医学
CiteScore
2.80
自引率
15.40%
发文量
68
审稿时长
6-12 weeks
期刊介绍: The aim of the Journal of Artificial Organs is to introduce to colleagues worldwide a broad spectrum of important new achievements in the field of artificial organs, ranging from fundamental research to clinical applications. The scope of the Journal of Artificial Organs encompasses but is not restricted to blood purification, cardiovascular intervention, biomaterials, and artificial metabolic organs. Additionally, the journal will cover technical and industrial innovations. Membership in the Japanese Society for Artificial Organs is not a prerequisite for submission.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信
小红书