Characterization of branched and linear polyethyleneimine by trapped ion mobility-time of flight-mass spectrometry

IF 6.1 2区 化学 Q1 CHEMISTRY, ANALYTICAL
Analytica Chimica Acta Pub Date : 2026-03-01 Epub Date: 2026-01-15 DOI:10.1016/j.aca.2026.345107
Faraz Mohammad Valipour , Mehmet Atakay , Sahin Demirci , Nurettin Sahiner , Bekir Salih
{"title":"Characterization of branched and linear polyethyleneimine by trapped ion mobility-time of flight-mass spectrometry","authors":"Faraz Mohammad Valipour ,&nbsp;Mehmet Atakay ,&nbsp;Sahin Demirci ,&nbsp;Nurettin Sahiner ,&nbsp;Bekir Salih","doi":"10.1016/j.aca.2026.345107","DOIUrl":null,"url":null,"abstract":"<div><h3>Background</h3><div>Polyethyleneimine (PEI) is a common polyelectrolyte that is used in many areas, such as drug delivery, gene therapy, and water treatment. This is because it has a highly branched structure, functional amine groups in its repeating unit, and a high cationic charge density. To understand the behavior and function of PEI, it is important to accurately describe its structure. The ion mobility-mass spectrometry method is expected to yield structural insights into PEI's molecular architecture, encompassing variations in branching patterns, chain conformations, and the potential presence of isomeric forms.</div></div><div><h3>Results</h3><div>The difference in zeta potential values between B-PEI and L-PEI can be attributed to the distinct types of functional amine groups present in their structures. The trapped ion mobility-time of flight-mass spectrometry (TIMS-ToF-MS) technique was used in this study to elucidate the molecular architecture of linear and branched PEI with varying polymeric distributions of ion series and end groups, concentrating on its dimensions, morphology, conformational variations, variable cationic adducts (Na<sup>+</sup>, K<sup>+</sup>, Li<sup>+</sup>, and Ag<sup>+</sup>), and charge states (+1 and + 2). The singly charged ions, like those in the main series and fragment series of PEI, are more compact than doubly charged ions because of the change in charge repulsion. TIMS, in conjunction with mass spectrometry, facilitated high-resolution separation of PEI conformers according to their collision cross-section (CCS) values and charge states.</div></div><div><h3>Significance</h3><div>The findings indicated that PEI displays a wide range of both compact and extended molecular conformations at various <em>m/z</em> ratios, with specific populations associated with varying branching levels, cationic adducts, and charge distribution. The influence of various metal ions on PEI conformation was examined, indicating substantial alterations in CCS values under diverse conditions of analysis. Hyphenated TIMS and MS technologies make a strong analytical platform for studying polymer structures in depth.</div></div>","PeriodicalId":240,"journal":{"name":"Analytica Chimica Acta","volume":"1389 ","pages":"Article 345107"},"PeriodicalIF":6.1000,"publicationDate":"2026-03-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Analytica Chimica Acta","FirstCategoryId":"92","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S0003267026000577","RegionNum":2,"RegionCategory":"化学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2026/1/15 0:00:00","PubModel":"Epub","JCR":"Q1","JCRName":"CHEMISTRY, ANALYTICAL","Score":null,"Total":0}
引用次数: 0

Abstract

Background

Polyethyleneimine (PEI) is a common polyelectrolyte that is used in many areas, such as drug delivery, gene therapy, and water treatment. This is because it has a highly branched structure, functional amine groups in its repeating unit, and a high cationic charge density. To understand the behavior and function of PEI, it is important to accurately describe its structure. The ion mobility-mass spectrometry method is expected to yield structural insights into PEI's molecular architecture, encompassing variations in branching patterns, chain conformations, and the potential presence of isomeric forms.

Results

The difference in zeta potential values between B-PEI and L-PEI can be attributed to the distinct types of functional amine groups present in their structures. The trapped ion mobility-time of flight-mass spectrometry (TIMS-ToF-MS) technique was used in this study to elucidate the molecular architecture of linear and branched PEI with varying polymeric distributions of ion series and end groups, concentrating on its dimensions, morphology, conformational variations, variable cationic adducts (Na+, K+, Li+, and Ag+), and charge states (+1 and + 2). The singly charged ions, like those in the main series and fragment series of PEI, are more compact than doubly charged ions because of the change in charge repulsion. TIMS, in conjunction with mass spectrometry, facilitated high-resolution separation of PEI conformers according to their collision cross-section (CCS) values and charge states.

Significance

The findings indicated that PEI displays a wide range of both compact and extended molecular conformations at various m/z ratios, with specific populations associated with varying branching levels, cationic adducts, and charge distribution. The influence of various metal ions on PEI conformation was examined, indicating substantial alterations in CCS values under diverse conditions of analysis. Hyphenated TIMS and MS technologies make a strong analytical platform for studying polymer structures in depth.

Abstract Image

用捕获离子迁移率-飞行时间-质谱法表征支化和线性聚乙烯亚胺
聚乙烯亚胺(PEI)是一种常见的聚电解质,广泛应用于药物输送、基因治疗和水处理等领域。这是因为它具有高度支化的结构,在其重复单元中有官能团,并且阳离子电荷密度高。为了理解PEI的行为和功能,准确描述其结构是非常重要的。离子迁移-质谱法有望产生PEI分子结构的结构见解,包括分支模式、链构象的变化和异构体形式的潜在存在。结果B-PEI和L-PEI之间的zeta电位值差异可归因于其结构中存在不同类型的功能胺基团。本研究利用捕获离子迁移时间飞行质谱(TIMS-ToF-MS)技术阐明了具有不同离子系列和端基聚合物分布的线性和支链PEI的分子结构,重点研究了其尺寸、形态、构象变化、不同阳离子加合物(Na+、K+、Li+和Ag+)和电荷态(+1和+ 2)。单电荷离子,如PEI的主系列和片段系列中的离子,由于电荷排斥力的变化,比双电荷离子更紧凑。TIMS结合质谱法,根据碰撞截面(CCS)值和电荷状态,促进了PEI构象的高分辨率分离。研究结果表明,PEI在不同的m/z比下显示出广泛的紧凑和扩展的分子构象,特定的种群与不同的分支水平、阳离子加合物和电荷分布有关。研究了各种金属离子对PEI构象的影响,表明在不同的分析条件下,CCS值发生了实质性的变化。TIMS和MS技术的结合为深入研究聚合物结构提供了强大的分析平台。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
Analytica Chimica Acta
Analytica Chimica Acta 化学-分析化学
CiteScore
10.40
自引率
6.50%
发文量
1081
审稿时长
38 days
期刊介绍: Analytica Chimica Acta has an open access mirror journal Analytica Chimica Acta: X, sharing the same aims and scope, editorial team, submission system and rigorous peer review. Analytica Chimica Acta provides a forum for the rapid publication of original research, and critical, comprehensive reviews dealing with all aspects of fundamental and applied modern analytical chemistry. The journal welcomes the submission of research papers which report studies concerning the development of new and significant analytical methodologies. In determining the suitability of submitted articles for publication, particular scrutiny will be placed on the degree of novelty and impact of the research and the extent to which it adds to the existing body of knowledge in analytical chemistry.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信
小红书