{"title":"Confounders, diagnostic accuracy, and reproducibility in cardiovascular magnetic resonance-feature tracking-derived left atrial strain: A Berlin Research Network for cardiovascular magnetic resonance multi-software, multi-site comparison.","authors":"Leo Dyke Krüger, Leonhard Grassow, Jan Gröschel, Johanna Kuhnt, Edyta Blaszczyk, Maximilian Müller, Ralf Felix Trauzeddel, Teodora Chitiboi, Jeanette Schulz-Menger, Maximilian Fenski","doi":"10.1016/j.jocmr.2026.102692","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>Cardiovascular magnetic resonance-feature tracking (CMR-FT) derived left atrial global longitudinal strain (LA-GLS) has prognostic relevance, even in the early stages of cardiovascular diseases. Identifying technical and subject-related confounders is essential for ensuring comparability across sites and for reliably distinguishing healthy from pathological conditions. This study aimed to evaluate the influence of post-processing software and subject-related factors on CMR-FT-derived LA-GLS, diagnostic accuracy, and to evaluate inter-site reproducibility.</p><p><strong>Methods: </strong>This study included 149 healthy individuals and 40 patients with atrial fibrillation (AF; 19 persistent, 21 paroxysmal) from a single site. A subgroup of 18 traveling volunteers underwent CMR at four different sites. All participants underwent CMR in sinus rhythm. LA-GLS was assessed using three post-processing software packages (CVI42, TrufiStrain Research Prototype, Medis). Mixed models with repeated measures were applied to evaluate the effect of software, site, and subject-related factors on LA-GLS components. ROC curve analysis was used to assess diagnostic accuracy across software in distinguishing healthy controls from AF patients.</p><p><strong>Results: </strong>All GLS components differed across post-processing software (p<.001). Reservoir and contractile GLS were lowest in CVI42 (23.9% ± 3.3%, 9.9% ± 2.2%), followed by TrufiStrain (27.4% ± 6.3%, 15.0% ± 4.8%) and Medis (45.4% ± 9.7%, 20.3% ± 5.7%). Conduit GLS was lowest in TrufiStrain (12.4% ± 4.8%), followed by CVI42 (16.3% ± 4.5%) and Medis (25.1% ± 8.2%). Among traveling volunteers, LA-GLS values were consistent across sites when the same software was used. Across all software, reservoir GLS negatively correlated with age. Diagnostic accuracy was comparable across software packages (AUC for reservoir strain: CVI: 0.81 [0.69-0.90], TrufiStrain 0.76 [0.64-0.88], Medis: 0.84 [0.72-0.94]).</p><p><strong>Conclusion: </strong>Post-processing software is a significant confounder in CMR-FT-based LA-GLS analysis and age substantially influences LA-GLS. LA-GLS demonstrates excellent inter-site reproducibility when analyzed with the same software and offers comparable diagnostic accuracy across platforms.</p>","PeriodicalId":15221,"journal":{"name":"Journal of Cardiovascular Magnetic Resonance","volume":" ","pages":"102692"},"PeriodicalIF":5.0000,"publicationDate":"2026-06-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC13196062/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Cardiovascular Magnetic Resonance","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1016/j.jocmr.2026.102692","RegionNum":1,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2026/1/15 0:00:00","PubModel":"Epub","JCR":"Q1","JCRName":"CARDIAC & CARDIOVASCULAR SYSTEMS","Score":null,"Total":0}
引用次数: 0

Abstract

Background: Cardiovascular magnetic resonance-feature tracking (CMR-FT) derived left atrial global longitudinal strain (LA-GLS) has prognostic relevance, even in the early stages of cardiovascular diseases. Identifying technical and subject-related confounders is essential for ensuring comparability across sites and for reliably distinguishing healthy from pathological conditions. This study aimed to evaluate the influence of post-processing software and subject-related factors on CMR-FT-derived LA-GLS, diagnostic accuracy, and to evaluate inter-site reproducibility.

Methods: This study included 149 healthy individuals and 40 patients with atrial fibrillation (AF; 19 persistent, 21 paroxysmal) from a single site. A subgroup of 18 traveling volunteers underwent CMR at four different sites. All participants underwent CMR in sinus rhythm. LA-GLS was assessed using three post-processing software packages (CVI42, TrufiStrain Research Prototype, Medis). Mixed models with repeated measures were applied to evaluate the effect of software, site, and subject-related factors on LA-GLS components. ROC curve analysis was used to assess diagnostic accuracy across software in distinguishing healthy controls from AF patients.

Results: All GLS components differed across post-processing software (p<.001). Reservoir and contractile GLS were lowest in CVI42 (23.9% ± 3.3%, 9.9% ± 2.2%), followed by TrufiStrain (27.4% ± 6.3%, 15.0% ± 4.8%) and Medis (45.4% ± 9.7%, 20.3% ± 5.7%). Conduit GLS was lowest in TrufiStrain (12.4% ± 4.8%), followed by CVI42 (16.3% ± 4.5%) and Medis (25.1% ± 8.2%). Among traveling volunteers, LA-GLS values were consistent across sites when the same software was used. Across all software, reservoir GLS negatively correlated with age. Diagnostic accuracy was comparable across software packages (AUC for reservoir strain: CVI: 0.81 [0.69-0.90], TrufiStrain 0.76 [0.64-0.88], Medis: 0.84 [0.72-0.94]).

Conclusion: Post-processing software is a significant confounder in CMR-FT-based LA-GLS analysis and age substantially influences LA-GLS. LA-GLS demonstrates excellent inter-site reproducibility when analyzed with the same software and offers comparable diagnostic accuracy across platforms.

混杂因素,诊断准确性和再现性在cmr特征跟踪衍生左心房应变:一个BER-CMR多软件,多站点比较。
目的:心血管磁共振特征跟踪(CMR-FT)衍生的左心房总纵向应变(LA-GLS)具有预后相关性,即使在心血管疾病的早期阶段。确定技术和主题相关的混杂因素对于确保各部位的可比性和可靠地区分健康和病理状况至关重要。本研究旨在评估后处理软件和受试者相关因素对CMR-FT衍生的LA-GLS、诊断准确性的影响,并评估位点间的可重复性。方法:本研究纳入149名健康个体和40例房颤患者(AF, 19例持续性,21例阵发性)。一个由18名旅行志愿者组成的小组在四个不同的地点接受了CMR。所有参与者均行窦性心律CMR。使用三个后处理软件包(CVI42、TrufiStrain Research Prototype、Medis)评估LA-GLS。采用重复测量的混合模型评价软件、场地和受试者相关因素对LA-GLS组分的影响。ROC曲线分析用于评估软件在区分健康对照和房颤患者方面的诊断准确性。结论:在基于CMR-FT的LA-GLS分析中,后处理软件是一个重要的混杂因素,年龄对LA-GLS有很大的影响。当使用相同的软件进行分析时,LA-GLS显示出出色的站点间再现性,并且在不同平台上提供相当的诊断准确性。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
CiteScore
10.90
自引率
12.50%
发文量
61
审稿时长
6-12 weeks
期刊介绍: Journal of Cardiovascular Magnetic Resonance (JCMR) publishes high-quality articles on all aspects of basic, translational and clinical research on the design, development, manufacture, and evaluation of cardiovascular magnetic resonance (CMR) methods applied to the cardiovascular system. Topical areas include, but are not limited to: New applications of magnetic resonance to improve the diagnostic strategies, risk stratification, characterization and management of diseases affecting the cardiovascular system. New methods to enhance or accelerate image acquisition and data analysis. Results of multicenter, or larger single-center studies that provide insight into the utility of CMR. Basic biological perceptions derived by CMR methods.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信
小红书