Creating a durable endoscopic ultrasound-guided gastroenteric anastomosis: A porcine-model pilot study

O.V. Hernández-Mondragón, J.C. Pintor-Belmontes, V.M. Rivera-Méndez, I. Bartnicky-Navarrete, E. Murcio-Pérez
{"title":"Creating a durable endoscopic ultrasound-guided gastroenteric anastomosis: A porcine-model pilot study","authors":"O.V. Hernández-Mondragón,&nbsp;J.C. Pintor-Belmontes,&nbsp;V.M. Rivera-Méndez,&nbsp;I. Bartnicky-Navarrete,&nbsp;E. Murcio-Pérez","doi":"10.1016/j.rgmxen.2025.12.003","DOIUrl":null,"url":null,"abstract":"<div><h3>Introduction and aims</h3><div>The performance of gastroenteric anastomosis (GEA) utilizing endoscopic ultrasound (EUS) and lumen-apposing metal stents (LAMSs) is safe and effective for treating malignant gastric outlet obstruction, but not in benign disease, due to unpredictable GEA closure after LAMS removal. Our aim was to evaluate different endoscopic techniques for creating a durable GEA in porcine models.</div></div><div><h3>Material and methods</h3><div>An animal study in porcine models was conducted at the vivarium of a tertiary care hospital in Mexico City, between September and November 2023. Five techniques were carried out: direct technique (DT), radial cut (RC) technique, linear cut (LC) technique, absolute ethanol sclerotherapy (AES), and argon plasma coagulation (APC). Technical efficacy, safety, and lasting patency of the anastomosis at 4 weeks after the intervention and LAMS removal were evaluated.</div></div><div><h3>Results</h3><div>Ten porcine models, 2 per group, were included. Technical success was 100% and clinical success 0%. Procedure times were 29 min for the DT, 88 min for the RC technique, 74 min for the LC technique, 41 min for AES, and 75 min for APC. The RC technique had the largest anastomosis area (742 mm<sup>2</sup>). There was one adverse event (10%); it was mild and did not require any additional intervention.</div></div><div><h3>Conclusions</h3><div>Although clinical success was not achieved with any of the techniques, the technical modifications were safe, providing a better understanding of the mechanisms involved in GEA and paving the way for new explorations.</div></div>","PeriodicalId":74705,"journal":{"name":"Revista de gastroenterologia de Mexico (English)","volume":"91 1","pages":"Pages 44-56"},"PeriodicalIF":0.0000,"publicationDate":"2026-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Revista de gastroenterologia de Mexico (English)","FirstCategoryId":"1085","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S2255534X25001665","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2026/1/15 0:00:00","PubModel":"Epub","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

Introduction and aims

The performance of gastroenteric anastomosis (GEA) utilizing endoscopic ultrasound (EUS) and lumen-apposing metal stents (LAMSs) is safe and effective for treating malignant gastric outlet obstruction, but not in benign disease, due to unpredictable GEA closure after LAMS removal. Our aim was to evaluate different endoscopic techniques for creating a durable GEA in porcine models.

Material and methods

An animal study in porcine models was conducted at the vivarium of a tertiary care hospital in Mexico City, between September and November 2023. Five techniques were carried out: direct technique (DT), radial cut (RC) technique, linear cut (LC) technique, absolute ethanol sclerotherapy (AES), and argon plasma coagulation (APC). Technical efficacy, safety, and lasting patency of the anastomosis at 4 weeks after the intervention and LAMS removal were evaluated.

Results

Ten porcine models, 2 per group, were included. Technical success was 100% and clinical success 0%. Procedure times were 29 min for the DT, 88 min for the RC technique, 74 min for the LC technique, 41 min for AES, and 75 min for APC. The RC technique had the largest anastomosis area (742 mm2). There was one adverse event (10%); it was mild and did not require any additional intervention.

Conclusions

Although clinical success was not achieved with any of the techniques, the technical modifications were safe, providing a better understanding of the mechanisms involved in GEA and paving the way for new explorations.

Abstract Image

创建一个持久的内镜超声引导胃肠道吻合:猪模型的初步研究。
前言和目的:利用超声内镜(EUS)和腔内金属支架(LAMSs)进行胃肠道吻合(GEA)治疗恶性胃出口梗阻是安全有效的,但在良性疾病中则不然,因为切除LAMS后GEA闭合不可预测。我们的目的是评估在猪模型中创建持久GEA的不同内窥镜技术。材料和方法:于2023年9月至11月在墨西哥城一家三级保健医院的动物园内进行了猪模型动物研究。采用直接法(DT)、径向切割法(RC)、线性切割法(LC)、无水乙醇硬化法(AES)和氩离子等离子凝固法(APC) 5种方法。评估术后4周吻合术的技术有效性、安全性和持续通畅程度。结果:共建立猪模型10只,每组2只。技术成功率100%,临床成功率0%。操作时间DT为29分钟,RC技术为88分钟,LC技术为74分钟,AES为41分钟,APC为75分钟。RC技术吻合面积最大(742 mm2)。有1例不良事件(10%);它是轻微的,不需要任何额外的干预。结论:虽然没有任何一种技术取得临床成功,但技术改进是安全的,提供了对GEA机制的更好理解,并为新的探索铺平了道路。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
审稿时长
12 weeks
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信
小红书