Workflow, Alarm Notification and Technology Acceptance of Continuous, Wearable-Based Vital Sign Monitoring on A Neurosurgical Ward-A Pilot Feasibility Study.

IF 2.7 2区 医学 Q2 ANESTHESIOLOGY
Joan Alsolivany, Lina Mosch, Lars Wessels, Laura Hallek, Tarik Alp Sargut, Claudia Spies, Peter Vajkoczy, Felix Balzer, Akira Poncette, Nils Hecht
{"title":"Workflow, Alarm Notification and Technology Acceptance of Continuous, Wearable-Based Vital Sign Monitoring on A Neurosurgical Ward-A Pilot Feasibility Study.","authors":"Joan Alsolivany, Lina Mosch, Lars Wessels, Laura Hallek, Tarik Alp Sargut, Claudia Spies, Peter Vajkoczy, Felix Balzer, Akira Poncette, Nils Hecht","doi":"10.1097/ANA.0000000000001094","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>Continuous, wearable-based vital sign monitoring can enhance patient safety and reduce intensive care demands but is not routinely used on standard neurosurgical wards. This study assessed alarm events and technology acceptance during the implementation of such a system for postoperative patients in a university hospital's neurosurgical ward.</p><p><strong>Methods: </strong>In this pilot feasibility study, selected patients were continuously monitored for 12 to 24 hours after elective neurosurgery on a 44-bed ward. Phase 1 (June to December 2019) used 12 mobile units with manual alarm documentation; Phase 2 (August 2023 to January 2024) used 44 fixed bedside units with automatic documentation. Alarm patterns and nurse-rated technology acceptance (4-point Likert scale) were analyzed.</p><p><strong>Results: </strong>Vital signs were monitored in 214 patients (median age: 58, IQR: 42 to 70) in Phase 1 and 290 patients (median age: 60, IQR: 43 to 77) in Phase 2. Procedures included cranial, spinal, and peripheral nerve surgeries. Phase 1 recorded 30 nonclinical alarms and no clinical alarms. In contrast, Phase 2 registered 14,500 clinical and 185,744 nonclinical alarms, mostly from detached sensors (177,989/185,744; 96%). Clinical alarms were mainly due to hypoxia (8305/14,500; 57%) and tachycardia (3487/14,500; 30%). Most alarms were acknowledged within 30 seconds (clinical: 12,969/14,500; 90% and nonclinical: 181,447/185,744; 98%), with delayed responses mostly for nonclinical events (3625/4189; 87%). Nurses reported improved convenience, usability, and system connection in Phase 2.</p><p><strong>Conclusions: </strong>Wearable-based vital sign monitoring is feasible on neurosurgical wards, but high nonclinical alarm rates highlight the need to refine alarm management strategies for effective clinical integration.</p>","PeriodicalId":16550,"journal":{"name":"Journal of neurosurgical anesthesiology","volume":" ","pages":"166-171"},"PeriodicalIF":2.7000,"publicationDate":"2026-04-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC12952484/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of neurosurgical anesthesiology","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1097/ANA.0000000000001094","RegionNum":2,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2026/1/13 0:00:00","PubModel":"Epub","JCR":"Q2","JCRName":"ANESTHESIOLOGY","Score":null,"Total":0}
引用次数: 0

Abstract

Background: Continuous, wearable-based vital sign monitoring can enhance patient safety and reduce intensive care demands but is not routinely used on standard neurosurgical wards. This study assessed alarm events and technology acceptance during the implementation of such a system for postoperative patients in a university hospital's neurosurgical ward.

Methods: In this pilot feasibility study, selected patients were continuously monitored for 12 to 24 hours after elective neurosurgery on a 44-bed ward. Phase 1 (June to December 2019) used 12 mobile units with manual alarm documentation; Phase 2 (August 2023 to January 2024) used 44 fixed bedside units with automatic documentation. Alarm patterns and nurse-rated technology acceptance (4-point Likert scale) were analyzed.

Results: Vital signs were monitored in 214 patients (median age: 58, IQR: 42 to 70) in Phase 1 and 290 patients (median age: 60, IQR: 43 to 77) in Phase 2. Procedures included cranial, spinal, and peripheral nerve surgeries. Phase 1 recorded 30 nonclinical alarms and no clinical alarms. In contrast, Phase 2 registered 14,500 clinical and 185,744 nonclinical alarms, mostly from detached sensors (177,989/185,744; 96%). Clinical alarms were mainly due to hypoxia (8305/14,500; 57%) and tachycardia (3487/14,500; 30%). Most alarms were acknowledged within 30 seconds (clinical: 12,969/14,500; 90% and nonclinical: 181,447/185,744; 98%), with delayed responses mostly for nonclinical events (3625/4189; 87%). Nurses reported improved convenience, usability, and system connection in Phase 2.

Conclusions: Wearable-based vital sign monitoring is feasible on neurosurgical wards, but high nonclinical alarm rates highlight the need to refine alarm management strategies for effective clinical integration.

神经外科病房A区连续可穿戴生命体征监测的工作流程、报警通知及技术验收试点可行性研究
背景:持续的、基于可穿戴的生命体征监测可以提高患者的安全性,减少重症监护需求,但在标准的神经外科病房并没有常规使用。本研究评估了该系统在某大学医院神经外科病房术后患者实施过程中的报警事件和技术接受程度。方法:在这项试点可行性研究中,选择患者在44张床位的病房进行选择性神经外科手术后连续监测12至24小时。第一阶段(2019年6月至12月)使用了12台带有手动报警文件的移动设备;第二阶段(2023年8月至2024年1月)使用了44台带有自动记录的固定床边设备。分析了报警模式和护士评定的技术接受度(4点李克特量表)。结果:第1期214例患者(中位年龄:58岁,IQR: 42 ~ 70)和第2期290例患者(中位年龄:60岁,IQR: 43 ~ 77)进行了生命体征监测。手术包括颅脑、脊柱和周围神经手术。第一阶段记录了30例非临床报警,无临床报警。相比之下,第二阶段登记了14,500例临床和185,744例非临床警报,主要来自分离的传感器(177,989/185,744;96%)。临床报警主要是缺氧(8305/ 14500,57%)和心动过速(3487/ 14500,30%)。大多数警报在30秒内被确认(临床:12,969/14,500;90%;非临床:181,447/185,744;98%),延迟响应主要针对非临床事件(3625/4189;87%)。护士报告说,在第二阶段,便利性、可用性和系统连接得到了改善。结论:基于可穿戴设备的生命体征监测在神经外科病房是可行的,但较高的非临床报警率表明需要完善报警管理策略,以实现有效的临床整合。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
CiteScore
6.20
自引率
10.80%
发文量
119
审稿时长
>12 weeks
期刊介绍: The Journal of Neurosurgical Anesthesiology (JNA) is a peer-reviewed publication directed to an audience of neuroanesthesiologists, neurosurgeons, neurosurgical monitoring specialists, neurosurgical support staff, and Neurosurgical Intensive Care Unit personnel. The journal publishes original peer-reviewed studies in the form of Clinical Investigations, Laboratory Investigations, Clinical Reports, Review Articles, Journal Club synopses of current literature from related journals, presentation of Points of View on controversial issues, Book Reviews, Correspondence, and Abstracts from affiliated neuroanesthesiology societies. JNA is the Official Journal of the Society for Neuroscience in Anesthesiology and Critical Care, the Neuroanaesthesia and Critical Care Society of Great Britain and Ireland, the Association de Neuro-Anesthésiologie Réanimation de langue Française, the Wissenschaftlicher Arbeitskreis Neuroanästhesie der Deutschen Gesellschaft fur Anästhesiologie und Intensivmedizen, the Arbeitsgemeinschaft Deutschsprachiger Neuroanästhesisten und Neuro-Intensivmediziner, the Korean Society of Neuroanesthesia, the Japanese Society of Neuroanesthesia and Critical Care, the Neuroanesthesiology Chapter of the Colegio Mexicano de Anesthesiología, the Indian Society of Neuroanesthesiology and Critical Care, and the Thai Society for Neuroanesthesia.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信
小红书