{"title":"Enhancing Screen-Printed Electrode Performance Through Simulation-Driven Design Optimization for Wearable Applications","authors":"Moritz Ploner;Lara Franchin;Antonio Altana;Bajramshahe Shkodra;Mattia Petrelli;Martina Aurora Costa Angeli;Michele Pompilio;Giulia Elli;Franco Cacialli;Alessandro Paccagnella;Daniele Resnati;Paolo Lugli;Stefano Bonaldo;Luisa Petti","doi":"10.1109/JFLEX.2025.3628346","DOIUrl":null,"url":null,"abstract":"Wearable biosensors are transforming remote health monitoring with noninvasive sweat biomarker detection. Nevertheless, achieving reliable sensing requires miniaturized, flexible platforms capable of detecting, with ultrahigh sensitivity, biomarker levels down to pg/mL scale. Electrochemical platforms, especially those using three-electrode platforms, hold significant promise but require careful geometric optimization to meet these needs. To address this, we evaluated four geometric layouts of screen-printed carbon three-electrode platforms on flexible polyethylene terephthalate (PET) substrates. Our investigation comprises experimental evaluations by means of cyclic voltammetry (CV) and electrochemical impedance spectroscopy (EIS), supported by simulations through a novel 3-D COMSOL Multiphysics model. The results reveal that a fourfold increase in the active area leads to a twofold increase in the CV peak currents, while reduced electrode spacing enhances current density and minimizes diffusion effects. Comparisons of experimental and simulated CV currents show that larger areas may be more prone to surface disuniformities, making performance more dependent on material properties than on area optimization. The EIS analysis reveals that a fourfold increase in the active area reduces charge transfer resistance (<inline-formula> <tex-math>$R_{\\text {CT}}$ </tex-math></inline-formula>) by 45%, while doubling the electrode distance results in a 29% increase in <inline-formula> <tex-math>$R_{\\text {CT}}$ </tex-math></inline-formula>, indicating inefficient charge transfer due to weakened electric fields and reduced charge carrier concentration. Our findings highlight the need for compact designs and simulation-guided geometric optimization for enhanced performance.","PeriodicalId":100623,"journal":{"name":"IEEE Journal on Flexible Electronics","volume":"5 1","pages":"3-13"},"PeriodicalIF":0.0000,"publicationDate":"2025-11-03","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"IEEE Journal on Flexible Electronics","FirstCategoryId":"1085","ListUrlMain":"https://ieeexplore.ieee.org/document/11224534/","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

Wearable biosensors are transforming remote health monitoring with noninvasive sweat biomarker detection. Nevertheless, achieving reliable sensing requires miniaturized, flexible platforms capable of detecting, with ultrahigh sensitivity, biomarker levels down to pg/mL scale. Electrochemical platforms, especially those using three-electrode platforms, hold significant promise but require careful geometric optimization to meet these needs. To address this, we evaluated four geometric layouts of screen-printed carbon three-electrode platforms on flexible polyethylene terephthalate (PET) substrates. Our investigation comprises experimental evaluations by means of cyclic voltammetry (CV) and electrochemical impedance spectroscopy (EIS), supported by simulations through a novel 3-D COMSOL Multiphysics model. The results reveal that a fourfold increase in the active area leads to a twofold increase in the CV peak currents, while reduced electrode spacing enhances current density and minimizes diffusion effects. Comparisons of experimental and simulated CV currents show that larger areas may be more prone to surface disuniformities, making performance more dependent on material properties than on area optimization. The EIS analysis reveals that a fourfold increase in the active area reduces charge transfer resistance ( $R_{\text {CT}}$ ) by 45%, while doubling the electrode distance results in a 29% increase in $R_{\text {CT}}$ , indicating inefficient charge transfer due to weakened electric fields and reduced charge carrier concentration. Our findings highlight the need for compact designs and simulation-guided geometric optimization for enhanced performance.
通过模拟驱动的可穿戴应用设计优化提高丝网印刷电极性能
可穿戴生物传感器正在通过无创汗液生物标志物检测改变远程健康监测。然而,实现可靠的传感需要小型化、灵活的平台,能够以超高的灵敏度检测低至pg/mL的生物标志物水平。电化学平台,特别是那些使用三电极的平台,具有很大的前景,但需要仔细的几何优化才能满足这些需求。为了解决这个问题,我们评估了丝网印刷碳三电极平台在柔性聚对苯二甲酸乙二醇酯(PET)衬底上的四种几何布局。我们的研究包括通过循环伏安法(CV)和电化学阻抗谱(EIS)进行实验评估,并通过新颖的3-D COMSOL多物理场模型进行模拟。结果表明,当电极面积增加4倍时,CV峰值电流增加2倍,而减小电极间距可提高电流密度并使扩散效应最小化。实验和模拟CV电流的比较表明,更大的区域可能更容易出现表面不均匀,使得性能更依赖于材料特性而不是面积优化。EIS分析表明,活性面积增加4倍,电荷转移电阻($R_{\text {CT}}$)降低45%,而电极距离增加一倍,电荷转移电阻($R_{\text {CT}}}$)增加29%,表明电场减弱导致电荷转移效率低下,载流子浓度降低。我们的研究结果强调需要紧凑的设计和模拟引导的几何优化,以提高性能。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信
小红书