Experimental study on the control effect of the coupling effect of micro-differential pressure and ventilation system on indoor particulate matter migration

IF 3.9 3区 环境科学与生态学 Q2 ENVIRONMENTAL SCIENCES
Atmospheric Pollution Research Pub Date : 2026-02-01 Epub Date: 2025-10-09 DOI:10.1016/j.apr.2025.102780
Yanhui Mao , Qiu Tu , Junjie He , Jianlin Ren
{"title":"Experimental study on the control effect of the coupling effect of micro-differential pressure and ventilation system on indoor particulate matter migration","authors":"Yanhui Mao ,&nbsp;Qiu Tu ,&nbsp;Junjie He ,&nbsp;Jianlin Ren","doi":"10.1016/j.apr.2025.102780","DOIUrl":null,"url":null,"abstract":"<div><div>The creation of micro-pressure differences (MPDs) is an important strategy in indoor environments control, especially in medical isolation wards and residential buildings. To better understand the role of MPDs, this study systematically investigated the effect of MPDs on the control of particulate matter (PM) exposure in a full-scale experimental chamber, taking into account the pollutant source location, door opening and closing, and human walking factors. A negative pressure (NA) combined with positive pressure (PA) system was set up to further investigate the coupling effect of MPD and the ventilation system. Results showed that the creation of MPD significantly reduced the dispersion of PM, where the cumulative exposure level (CEL) was reduced by 61.5 % from the baseline when the source was located in NA. When the source was located in PA, the form of airflow organization had a significant effect on the performance of the coupling system. The side supply and side return airflows performed best, with relatively lower CEL value (6.06–7.29 × 10<sup>7</sup> particles cm<sup>−3</sup>) and the highest robustness (DR: 0.88) for door opening and closing and walking cases. In addition, the traditional metric (CEL, Welly-Riley equation) and new metric (robustness analysis: both PM removal efficiency and walking disturbance control effects) for evaluating ventilation systems were compared, and the Welly-Riley equation was used to correct the weights assigned to PM removal and walking disturbance in the robustness calculations. The highly stable ventilation configuration derived from the above metrics can provide design references for medical isolation wards and residential buildings.</div></div>","PeriodicalId":8604,"journal":{"name":"Atmospheric Pollution Research","volume":"17 2","pages":"Article 102780"},"PeriodicalIF":3.9000,"publicationDate":"2026-02-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Atmospheric Pollution Research","FirstCategoryId":"93","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S1309104225003824","RegionNum":3,"RegionCategory":"环境科学与生态学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2025/10/9 0:00:00","PubModel":"Epub","JCR":"Q2","JCRName":"ENVIRONMENTAL SCIENCES","Score":null,"Total":0}
引用次数: 0

Abstract

The creation of micro-pressure differences (MPDs) is an important strategy in indoor environments control, especially in medical isolation wards and residential buildings. To better understand the role of MPDs, this study systematically investigated the effect of MPDs on the control of particulate matter (PM) exposure in a full-scale experimental chamber, taking into account the pollutant source location, door opening and closing, and human walking factors. A negative pressure (NA) combined with positive pressure (PA) system was set up to further investigate the coupling effect of MPD and the ventilation system. Results showed that the creation of MPD significantly reduced the dispersion of PM, where the cumulative exposure level (CEL) was reduced by 61.5 % from the baseline when the source was located in NA. When the source was located in PA, the form of airflow organization had a significant effect on the performance of the coupling system. The side supply and side return airflows performed best, with relatively lower CEL value (6.06–7.29 × 107 particles cm−3) and the highest robustness (DR: 0.88) for door opening and closing and walking cases. In addition, the traditional metric (CEL, Welly-Riley equation) and new metric (robustness analysis: both PM removal efficiency and walking disturbance control effects) for evaluating ventilation systems were compared, and the Welly-Riley equation was used to correct the weights assigned to PM removal and walking disturbance in the robustness calculations. The highly stable ventilation configuration derived from the above metrics can provide design references for medical isolation wards and residential buildings.
微差压与通风系统耦合效应对室内颗粒物迁移控制效果的实验研究
创建微压差(MPDs)是室内环境控制的重要策略,特别是在医疗隔离病房和住宅建筑中。为了更好地理解MPDs的作用,本研究在一个全尺寸的实验室内系统地研究了MPDs对颗粒物(PM)暴露控制的影响,考虑了污染源位置、门的开启和关闭以及人的行走因素。建立负压(NA) +正压(PA)系统,进一步研究MPD与通风系统的耦合效应。结果表明,MPD的产生显著降低了PM的扩散,当源位于NA时,累积暴露水平(CEL)比基线降低了61.5%。当源位于PA内时,气流组织形式对耦合系统的性能有显著影响。侧送风和侧回风表现最好,相对较低的CEL值(6.06-7.29 × 107颗粒cm−3)和最高的鲁棒性(DR: 0.88),适用于开门、关门和行走情况。此外,比较了评价通风系统的传统度量(CEL, Welly-Riley方程)和新度量(鲁棒性分析:PM去除效率和行走干扰控制效果),并使用Welly-Riley方程对鲁棒性计算中PM去除和行走干扰的权重进行了修正。由上述指标推导出的高度稳定的通风配置,可为医疗隔离病房和住宅建筑提供设计参考。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
Atmospheric Pollution Research
Atmospheric Pollution Research ENVIRONMENTAL SCIENCES-
CiteScore
8.30
自引率
6.70%
发文量
256
审稿时长
36 days
期刊介绍: Atmospheric Pollution Research (APR) is an international journal designed for the publication of articles on air pollution. Papers should present novel experimental results, theory and modeling of air pollution on local, regional, or global scales. Areas covered are research on inorganic, organic, and persistent organic air pollutants, air quality monitoring, air quality management, atmospheric dispersion and transport, air-surface (soil, water, and vegetation) exchange of pollutants, dry and wet deposition, indoor air quality, exposure assessment, health effects, satellite measurements, natural emissions, atmospheric chemistry, greenhouse gases, and effects on climate change.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信
小红书