Quantitative Multifrequency Ultrasound Imaging Using Narrowband Pulsing for Tissue Characterization.

IF 7.9 1区 医学 Q1 RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING
Joshua Hanson, Chaodong Wu, Kenneth Hoyt
{"title":"Quantitative Multifrequency Ultrasound Imaging Using Narrowband Pulsing for Tissue Characterization.","authors":"Joshua Hanson, Chaodong Wu, Kenneth Hoyt","doi":"10.1097/RLI.0000000000001269","DOIUrl":null,"url":null,"abstract":"<p><strong>Objective: </strong>Multifrequency ultrasound (MFUS) is a novel quantitative imaging technique that captures backscattered data after transmission of a sequence of frequency-shifted narrowband ultrasound (US) pulses. The goal of this study was to implement a MFUS acquisition sequence and then validate quantitative measurements using an animal model of metabolic dysfunction-associated steatotic liver disease (MASLD).</p><p><strong>Materials and methods: </strong>US imaging was performed using a programmable research scanner (Vantage NXT 256, Verasonics Inc) equipped with a L11-5v linear array. Radiofrequency (RF) data were acquired from 24 different frequency-shifted narrowband transmit pulses using plane wave imaging with spatial angular compounding. The MFUS gradient was defined as the linear slope between logarithmic B-scan intensity and transmit frequency. The US attenuation coefficient and relative scatterer size (RSS) were derived from the MFUS gradient parameter. A bilayer tissue-mimicking phantom with regions of known US attenuation values of -0.70 and -0.95 dB/cm/MHz, respectively, was used for in vitro MFUS imaging and attenuation coefficient estimation. Custom homogeneous phantoms containing 38 to 89 µm-sized US scatterers were also used to compare RSS estimates. A heterogeneous phantom containing a circular target and background material embedded with 64 and 38 µm-sized scatterers, respectively, was used to measure the contrast-to-noise ratio (CNR) between the two regions for B-scan and MFUS-derived RSS estimates. Preclinical US imaging was performed on mice fed standard chow or a methionine and choline-deficient (MCD) diet to induce liver steatosis ( n =5 animals per group). Mice underwent in vivo MFUS imaging, and then attenuation coefficient and RSS estimates were derived for each mouse liver.</p><p><strong>Results: </strong>In vitro attenuation estimates were found to be -0.71 ± 0.04 and -0.93 ± 0.03 dB/cm/MHz for a phantom with true attenuation values of -0.70 and -0.95 dB/cm/MHz, respectively. A difference was found in RSS values from homogenous phantoms embedded with different-sized US scatterers and CNR measurements from the heterogeneous inclusion phantom ( P < 0.001). Average CNR values increased from 0.11 to 0.30 when using B-scan and MFUS imaging, respectively. Relative to control animals, in vivo liver imaging studies revealed increased attenuation coefficient and decreased RSS values in mice fed the MCD diet ( P < 0.001). After US imaging, all animals were humanely euthanized and livers excised for histologic analysis.</p><p><strong>Conclusion: </strong>MFUS imaging of phantom materials revealed a sensitivity to changes in attenuation coefficient and US scatterer size conditions. Preliminary preclinical results validated the performance of MFUS-derived parameters for liver tissue characterization. Changes in attenuation coefficient and RSS values were consistent with previous studies. Overall, MFUS is an innovative imaging technique, and future studies will explore further optimization and potential applications.</p>","PeriodicalId":14486,"journal":{"name":"Investigative Radiology","volume":" ","pages":"636-644"},"PeriodicalIF":7.9000,"publicationDate":"2026-09-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC12917945/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Investigative Radiology","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1097/RLI.0000000000001269","RegionNum":1,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING","Score":null,"Total":0}
引用次数: 0

Abstract

Objective: Multifrequency ultrasound (MFUS) is a novel quantitative imaging technique that captures backscattered data after transmission of a sequence of frequency-shifted narrowband ultrasound (US) pulses. The goal of this study was to implement a MFUS acquisition sequence and then validate quantitative measurements using an animal model of metabolic dysfunction-associated steatotic liver disease (MASLD).

Materials and methods: US imaging was performed using a programmable research scanner (Vantage NXT 256, Verasonics Inc) equipped with a L11-5v linear array. Radiofrequency (RF) data were acquired from 24 different frequency-shifted narrowband transmit pulses using plane wave imaging with spatial angular compounding. The MFUS gradient was defined as the linear slope between logarithmic B-scan intensity and transmit frequency. The US attenuation coefficient and relative scatterer size (RSS) were derived from the MFUS gradient parameter. A bilayer tissue-mimicking phantom with regions of known US attenuation values of -0.70 and -0.95 dB/cm/MHz, respectively, was used for in vitro MFUS imaging and attenuation coefficient estimation. Custom homogeneous phantoms containing 38 to 89 µm-sized US scatterers were also used to compare RSS estimates. A heterogeneous phantom containing a circular target and background material embedded with 64 and 38 µm-sized scatterers, respectively, was used to measure the contrast-to-noise ratio (CNR) between the two regions for B-scan and MFUS-derived RSS estimates. Preclinical US imaging was performed on mice fed standard chow or a methionine and choline-deficient (MCD) diet to induce liver steatosis ( n =5 animals per group). Mice underwent in vivo MFUS imaging, and then attenuation coefficient and RSS estimates were derived for each mouse liver.

Results: In vitro attenuation estimates were found to be -0.71 ± 0.04 and -0.93 ± 0.03 dB/cm/MHz for a phantom with true attenuation values of -0.70 and -0.95 dB/cm/MHz, respectively. A difference was found in RSS values from homogenous phantoms embedded with different-sized US scatterers and CNR measurements from the heterogeneous inclusion phantom ( P < 0.001). Average CNR values increased from 0.11 to 0.30 when using B-scan and MFUS imaging, respectively. Relative to control animals, in vivo liver imaging studies revealed increased attenuation coefficient and decreased RSS values in mice fed the MCD diet ( P < 0.001). After US imaging, all animals were humanely euthanized and livers excised for histologic analysis.

Conclusion: MFUS imaging of phantom materials revealed a sensitivity to changes in attenuation coefficient and US scatterer size conditions. Preliminary preclinical results validated the performance of MFUS-derived parameters for liver tissue characterization. Changes in attenuation coefficient and RSS values were consistent with previous studies. Overall, MFUS is an innovative imaging technique, and future studies will explore further optimization and potential applications.

利用窄带脉冲定量多频超声成像进行组织表征。
目的:多频超声(MFUS)是一种新型的定量成像技术,在传输一系列频移窄带超声(US)脉冲后捕获背散射数据。本研究的目的是实现MFUS采集序列,然后使用代谢功能障碍相关脂肪变性肝病(MASLD)动物模型验证定量测量。材料和方法:使用配备L11-5v线性阵列的可编程研究扫描仪(Vantage NXT 256, Verasonics Inc)进行超声成像。采用空间角复合平面波成像技术,从24个不同的频移窄带发射脉冲中获取射频数据。MFUS梯度定义为对数b扫描强度与发射频率之间的线性斜率。从MFUS梯度参数推导出US衰减系数和相对散射体尺寸(RSS)。一个双层组织模拟体,其已知US衰减值分别为-0.70和-0.95 dB/cm/MHz,用于体外MFUS成像和衰减系数估计。还使用含有38至89微米大小的US散射体的自定义均匀模型来比较RSS估计。一个包含圆形目标和背景材料的异质体分别嵌入64微米和38微米大小的散射体,用于测量b扫描和mfus衍生的RSS估计的两个区域之间的对比噪声比(CNR)。用标准食物或蛋氨酸和胆碱缺乏(MCD)饮食诱导肝脏脂肪变性的小鼠进行临床前超声成像(每组n=5只)。对小鼠进行体内MFUS成像,然后得出每只小鼠肝脏的衰减系数和相对过饱和度估计。结果:体外衰减估计值分别为-0.71±0.04和-0.93±0.03 dB/cm/MHz,真实衰减值分别为-0.70和-0.95 dB/cm/MHz。嵌入不同大小的US散射体的均匀模型的RSS值和非均匀包含体的CNR测量值存在差异(P < 0.001)。使用b扫描和MFUS成像时,平均CNR值分别从0.11增加到0.30。与对照动物相比,体内肝脏成像研究显示,MCD饮食小鼠的衰减系数增加,RSS值降低(P < 0.001)。超声显像后,所有动物被人道安乐死,并切除肝脏进行组织学分析。结论:幻体材料的MFUS成像对衰减系数和US散射体大小的变化具有敏感性。初步临床前结果验证了mfus衍生参数用于肝组织表征的性能。衰减系数和RSS值的变化与前人研究一致。总的来说,MFUS是一种创新的成像技术,未来的研究将探索进一步的优化和潜在的应用。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
Investigative Radiology
Investigative Radiology 医学-核医学
CiteScore
15.10
自引率
16.40%
发文量
188
审稿时长
4-8 weeks
期刊介绍: Investigative Radiology publishes original, peer-reviewed reports on clinical and laboratory investigations in diagnostic imaging, the diagnostic use of radioactive isotopes, computed tomography, positron emission tomography, magnetic resonance imaging, ultrasound, digital subtraction angiography, and related modalities. Emphasis is on early and timely publication. Primarily research-oriented, the journal also includes a wide variety of features of interest to clinical radiologists.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信
小红书