{"title":"Dynamic response and output characteristics of high-speed on/off valves based on structural optimization and load force characterization","authors":"Zibo Chen , Rulu Wei , Zuzhi Tian , Fangwei Xie , Nan Chen","doi":"10.1016/j.flowmeasinst.2025.103181","DOIUrl":null,"url":null,"abstract":"<div><div>Addressing the challenges in accurately predicting the frequency response and flow output of high-speed on/off valves (HSVs) in digital hydraulic systems, this study investigates their dynamic response and output characteristics through integrated electromechanical-hydraulic co-simulation and experimental testing. A dynamic model of the HSV, including its load, is established. An analysis method for dynamic performance, based on the load force function, is proposed to examine the valve's opening and closing behavior and the resulting flow characteristics. Structural parameters are subsequently optimized. Results show that the optimized valve exhibits significantly reduced opening and closing times, and its cutoff frequency increases from 37 Hz to 53 Hz. Additionally, it is found that an increase in operating frequency narrows the linear flow modulation range and reduces output flow, while a decrease in pressure differential leads to a parabolic decay in output. Experimental results validate the simulation, demonstrating that the prototype achieves a linear modulation range of 30 %–70 % at 40 Hz and a maximum operating frequency of 60 Hz. This research establishes an integrated electromagnetic-mechanical-hydraulic load force model and proposes a structural optimization framework based on load force characterization. This provides a new co-design approach for the synergistic optimization and precise control of HSVs.</div></div>","PeriodicalId":50440,"journal":{"name":"Flow Measurement and Instrumentation","volume":"108 ","pages":"Article 103181"},"PeriodicalIF":3.3000,"publicationDate":"2026-03-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Flow Measurement and Instrumentation","FirstCategoryId":"5","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S0955598625003735","RegionNum":3,"RegionCategory":"工程技术","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2025/12/30 0:00:00","PubModel":"Epub","JCR":"Q2","JCRName":"ENGINEERING, MECHANICAL","Score":null,"Total":0}
引用次数: 0
Abstract
Addressing the challenges in accurately predicting the frequency response and flow output of high-speed on/off valves (HSVs) in digital hydraulic systems, this study investigates their dynamic response and output characteristics through integrated electromechanical-hydraulic co-simulation and experimental testing. A dynamic model of the HSV, including its load, is established. An analysis method for dynamic performance, based on the load force function, is proposed to examine the valve's opening and closing behavior and the resulting flow characteristics. Structural parameters are subsequently optimized. Results show that the optimized valve exhibits significantly reduced opening and closing times, and its cutoff frequency increases from 37 Hz to 53 Hz. Additionally, it is found that an increase in operating frequency narrows the linear flow modulation range and reduces output flow, while a decrease in pressure differential leads to a parabolic decay in output. Experimental results validate the simulation, demonstrating that the prototype achieves a linear modulation range of 30 %–70 % at 40 Hz and a maximum operating frequency of 60 Hz. This research establishes an integrated electromagnetic-mechanical-hydraulic load force model and proposes a structural optimization framework based on load force characterization. This provides a new co-design approach for the synergistic optimization and precise control of HSVs.
期刊介绍:
Flow Measurement and Instrumentation is dedicated to disseminating the latest research results on all aspects of flow measurement, in both closed conduits and open channels. The design of flow measurement systems involves a wide variety of multidisciplinary activities including modelling the flow sensor, the fluid flow and the sensor/fluid interactions through the use of computation techniques; the development of advanced transducer systems and their associated signal processing and the laboratory and field assessment of the overall system under ideal and disturbed conditions.
FMI is the essential forum for critical information exchange, and contributions are particularly encouraged in the following areas of interest:
Modelling: the application of mathematical and computational modelling to the interaction of fluid dynamics with flowmeters, including flowmeter behaviour, improved flowmeter design and installation problems. Application of CAD/CAE techniques to flowmeter modelling are eligible.
Design and development: the detailed design of the flowmeter head and/or signal processing aspects of novel flowmeters. Emphasis is given to papers identifying new sensor configurations, multisensor flow measurement systems, non-intrusive flow metering techniques and the application of microelectronic techniques in smart or intelligent systems.
Calibration techniques: including descriptions of new or existing calibration facilities and techniques, calibration data from different flowmeter types, and calibration intercomparison data from different laboratories.
Installation effect data: dealing with the effects of non-ideal flow conditions on flowmeters. Papers combining a theoretical understanding of flowmeter behaviour with experimental work are particularly welcome.