{"title":"Study on irreversibility in an ejector with zeotropic mixtures using direct entropy analysis method","authors":"Zhengshu Dai , Jiaxin Xiang , Shuai Qin , Hua Zhang","doi":"10.1016/j.ijrefrig.2025.12.032","DOIUrl":null,"url":null,"abstract":"<div><div>Ejector refrigeration attracts more attention due to the intense increase of space cooling requirements and energy crises. Significant irreversibility inside the ejector hinders its applications by lowering ejector efficiency and system performance. Thus, it is important to understand the distribution of irreversibility inside the ejector and the effects of operating conditions and ejector geometries on irreversibility. A two-dimensional numerical model is developed considering direct entropy analysis method and real gas refrigerant property. Zeotropic mixture R134a/R32 is selected. Effects of primary and secondary flow pressure, ejector back pressure, nozzle throat and mixing chamber diameter on three types of entropy generation within the ejector are investigated. Results show that the turbulent dissipation entropy generation dominates the total entropy generation in all cases. As the primary flow pressure varies from 2588.80 kPa to 3188.80 kPa, the entrainment ratio first increases from 0.127 to 0.461 and then decreases to 0.400. The direct dissipation entropy generation mainly occurs in the divergent part of the nozzle and the mixing chamber, while the heat transfer entropy generation mainly occurs in the mixing shear layer and where the shock train occurs. As the secondary flow pressure changes from 334.61 kPa to 494.61 kPa, the entrainment ratio increases from 0.155 to 0.589, and the turbulent dissipation entropy generation decreases from 3.557 W/K to 2.667 W/K and then remains almost constant. As the ejector back pressure changes from 726.57 kPa to 900.57 kPa, the minimum total entropy generation is achieved at critical point.</div></div>","PeriodicalId":14274,"journal":{"name":"International Journal of Refrigeration-revue Internationale Du Froid","volume":"183 ","pages":"Pages 108-122"},"PeriodicalIF":4.0000,"publicationDate":"2026-03-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"International Journal of Refrigeration-revue Internationale Du Froid","FirstCategoryId":"5","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S0140700725004931","RegionNum":2,"RegionCategory":"工程技术","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2025/12/29 0:00:00","PubModel":"Epub","JCR":"Q1","JCRName":"ENGINEERING, MECHANICAL","Score":null,"Total":0}
引用次数: 0
Abstract
Ejector refrigeration attracts more attention due to the intense increase of space cooling requirements and energy crises. Significant irreversibility inside the ejector hinders its applications by lowering ejector efficiency and system performance. Thus, it is important to understand the distribution of irreversibility inside the ejector and the effects of operating conditions and ejector geometries on irreversibility. A two-dimensional numerical model is developed considering direct entropy analysis method and real gas refrigerant property. Zeotropic mixture R134a/R32 is selected. Effects of primary and secondary flow pressure, ejector back pressure, nozzle throat and mixing chamber diameter on three types of entropy generation within the ejector are investigated. Results show that the turbulent dissipation entropy generation dominates the total entropy generation in all cases. As the primary flow pressure varies from 2588.80 kPa to 3188.80 kPa, the entrainment ratio first increases from 0.127 to 0.461 and then decreases to 0.400. The direct dissipation entropy generation mainly occurs in the divergent part of the nozzle and the mixing chamber, while the heat transfer entropy generation mainly occurs in the mixing shear layer and where the shock train occurs. As the secondary flow pressure changes from 334.61 kPa to 494.61 kPa, the entrainment ratio increases from 0.155 to 0.589, and the turbulent dissipation entropy generation decreases from 3.557 W/K to 2.667 W/K and then remains almost constant. As the ejector back pressure changes from 726.57 kPa to 900.57 kPa, the minimum total entropy generation is achieved at critical point.
期刊介绍:
The International Journal of Refrigeration is published for the International Institute of Refrigeration (IIR) by Elsevier. It is essential reading for all those wishing to keep abreast of research and industrial news in refrigeration, air conditioning and associated fields. This is particularly important in these times of rapid introduction of alternative refrigerants and the emergence of new technology. The journal has published special issues on alternative refrigerants and novel topics in the field of boiling, condensation, heat pumps, food refrigeration, carbon dioxide, ammonia, hydrocarbons, magnetic refrigeration at room temperature, sorptive cooling, phase change materials and slurries, ejector technology, compressors, and solar cooling.
As well as original research papers the International Journal of Refrigeration also includes review articles, papers presented at IIR conferences, short reports and letters describing preliminary results and experimental details, and letters to the Editor on recent areas of discussion and controversy. Other features include forthcoming events, conference reports and book reviews.
Papers are published in either English or French with the IIR news section in both languages.