Structural finite element analysis of the lumbar spine applied to the conceptual design of a compliant interbody cage implant

IF 4.1 2区 医学 Q2 ENGINEERING, BIOMEDICAL
Gabriele Cortis , Alessandro Agostinelli , Luca Cortese
{"title":"Structural finite element analysis of the lumbar spine applied to the conceptual design of a compliant interbody cage implant","authors":"Gabriele Cortis ,&nbsp;Alessandro Agostinelli ,&nbsp;Luca Cortese","doi":"10.1016/j.jmbbm.2025.107314","DOIUrl":null,"url":null,"abstract":"<div><div>A detailed solid model of an entire lumbar segment is reconstructed through a reverse engineering approach based on a real patient Computed Tomography DICOM scan. The main structurally and functionally relevant elements have been considered in the model, including the L1-S1 vertebrae, intervertebral discs, ligaments, and the simplified structural and bracing effects of the principal lumbar muscles. Using the model, a structural Finite Element (FE) analysis is setup to provide an insight of stresses and range of motion of the “spinal mechanical system” under typical everyday as well as accidental loads. Organic bone, discs, ligaments physical and structural material data have been retrieved, and both static and fatigue load cases have been taken into account, collecting real world data from a review of literature works and of information available from accessible databases. A validation of the FE model is provided based on the so called Yamamoto protocol first, and then using experimental measurements performed on real patients, again taken from literature works. The numerical model proved to be accurate in the description of the stress states of the different parts of the spine and in reproducing the overall range of motion of the lumbar segment. A tentative design modification of rigid interbody cages and vertebral fixation systems used in present spinal fusion neurosurgery is then proposed, aimed at providing a certain level of compliance to the implant. This should restore a limited range of motion of the two adjacent vertebrae hosting the implant itself, reducing the possibility of subsequent adjacent segments diseases. The new cage and fixation system have been integrated in the FE model to replace a prospective “damaged” L4-L5 disc. The results of the numerical simulation demonstrated that the implant can withstand static and fatigue everyday life loads, as well as accidental overloads without failing. Additionally, the analysis showed that a limited mobility is maintained between the fused vertebrae.</div></div>","PeriodicalId":380,"journal":{"name":"Journal of the Mechanical Behavior of Biomedical Materials","volume":"175 ","pages":"Article 107314"},"PeriodicalIF":4.1000,"publicationDate":"2026-03-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of the Mechanical Behavior of Biomedical Materials","FirstCategoryId":"5","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S1751616125004308","RegionNum":2,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2025/12/22 0:00:00","PubModel":"Epub","JCR":"Q2","JCRName":"ENGINEERING, BIOMEDICAL","Score":null,"Total":0}
引用次数: 0

Abstract

A detailed solid model of an entire lumbar segment is reconstructed through a reverse engineering approach based on a real patient Computed Tomography DICOM scan. The main structurally and functionally relevant elements have been considered in the model, including the L1-S1 vertebrae, intervertebral discs, ligaments, and the simplified structural and bracing effects of the principal lumbar muscles. Using the model, a structural Finite Element (FE) analysis is setup to provide an insight of stresses and range of motion of the “spinal mechanical system” under typical everyday as well as accidental loads. Organic bone, discs, ligaments physical and structural material data have been retrieved, and both static and fatigue load cases have been taken into account, collecting real world data from a review of literature works and of information available from accessible databases. A validation of the FE model is provided based on the so called Yamamoto protocol first, and then using experimental measurements performed on real patients, again taken from literature works. The numerical model proved to be accurate in the description of the stress states of the different parts of the spine and in reproducing the overall range of motion of the lumbar segment. A tentative design modification of rigid interbody cages and vertebral fixation systems used in present spinal fusion neurosurgery is then proposed, aimed at providing a certain level of compliance to the implant. This should restore a limited range of motion of the two adjacent vertebrae hosting the implant itself, reducing the possibility of subsequent adjacent segments diseases. The new cage and fixation system have been integrated in the FE model to replace a prospective “damaged” L4-L5 disc. The results of the numerical simulation demonstrated that the implant can withstand static and fatigue everyday life loads, as well as accidental overloads without failing. Additionally, the analysis showed that a limited mobility is maintained between the fused vertebrae.
腰椎结构有限元分析应用于柔性椎间笼植入物的概念设计
通过基于真实患者计算机断层扫描DICOM扫描的逆向工程方法重建整个腰椎节段的详细实体模型。该模型考虑了主要的结构和功能相关因素,包括L1-S1椎体、椎间盘、韧带以及主要腰肌的简化结构和支撑作用。利用该模型,建立了结构有限元(FE)分析,以提供在典型的日常载荷和意外载荷下“脊柱机械系统”的应力和运动范围的洞察力。检索了有机骨、椎间盘、韧带物理和结构材料数据,并考虑了静态和疲劳载荷情况,从文献作品的审查和可访问的数据库中收集了真实世界的数据。首先根据所谓的山本协议对有限元模型进行验证,然后使用对真实患者进行的实验测量,再次取自文献作品。该数值模型在描述脊柱不同部位的应力状态和再现腰椎节段的整体运动范围方面被证明是准确的。然后提出了目前脊柱融合神经外科中使用的刚性椎间固定架和椎体固定系统的初步设计修改,旨在提供一定程度的植入物顺应性。这将恢复两个相邻椎体承载植入物本身的有限活动范围,减少随后相邻节段疾病的可能性。新的笼和固定系统已集成到FE模型中,以取代预期“受损”的L4-L5椎间盘。数值模拟结果表明,该种植体可以承受日常生活中的静态和疲劳载荷,以及意外过载而不会失效。此外,分析显示融合椎体之间保持了有限的活动能力。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
Journal of the Mechanical Behavior of Biomedical Materials
Journal of the Mechanical Behavior of Biomedical Materials 工程技术-材料科学:生物材料
CiteScore
7.20
自引率
7.70%
发文量
505
审稿时长
46 days
期刊介绍: The Journal of the Mechanical Behavior of Biomedical Materials is concerned with the mechanical deformation, damage and failure under applied forces, of biological material (at the tissue, cellular and molecular levels) and of biomaterials, i.e. those materials which are designed to mimic or replace biological materials. The primary focus of the journal is the synthesis of materials science, biology, and medical and dental science. Reports of fundamental scientific investigations are welcome, as are articles concerned with the practical application of materials in medical devices. Both experimental and theoretical work is of interest; theoretical papers will normally include comparison of predictions with experimental data, though we recognize that this may not always be appropriate. The journal also publishes technical notes concerned with emerging experimental or theoretical techniques, letters to the editor and, by invitation, review articles and papers describing existing techniques for the benefit of an interdisciplinary readership.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信
小红书