A centroid iterative method for fitting the femoral neck axis in rotational osteotomy: a finite element analysis and biomechanical investigation.

IF 1.6 4区 医学 Q3 ORTHOPEDICS
Journal of Hip Preservation Surgery Pub Date : 2025-05-08 eCollection Date: 2025-12-01 DOI:10.1093/jhps/hnaf026
Liang Chen, Zexin Hong, Zhentao Ding, Jingyang Chen, Zhuohua Liu, Chenglin Chen, Yufeng Wu, Jianhai Chen, Dawei Gao
{"title":"A centroid iterative method for fitting the femoral neck axis in rotational osteotomy: a finite element analysis and biomechanical investigation.","authors":"Liang Chen, Zexin Hong, Zhentao Ding, Jingyang Chen, Zhuohua Liu, Chenglin Chen, Yufeng Wu, Jianhai Chen, Dawei Gao","doi":"10.1093/jhps/hnaf026","DOIUrl":null,"url":null,"abstract":"<p><p>The femoral neck axis (FNA) is an important reference in femoral neck rotational osteotomy, which is a hip preservation procedure. The purpose of this study was to propose a method for determining the FNA with high accuracy and reliability and to evaluate the effect of FNA determination accuracy on the stress and strain distribution in the proximal femur. Femoral computed tomography data from 50 patients were reconstructed, and the FNA was fitted by the centroid iterative method. The fitting accuracy was evaluated in terms of the distance between the femoral head centre and the FNA. The reliability was assessed by intraclass correlation coefficient (ICC). Stress-strain distributions of the native femur model and rotational osteotomy models with accurate FNA and deviated FNA were simulated by finite element analysis and digital image correlation methods. The distance between the femoral head centre and the FNA was 1.24 ± 0.35 mm. The intra- and interobserver reliability was high, with ICC values of 0.960 and 0.924, respectively. The maximum von Mises stress was 25.76 MPa, 50.82 MPa, and 93.24 MPa for the native femur model, accurate FNA model, and deviated FNA model, respectively. The finite element strain distributions were linearly correlated with digital image correlation results. The centroid iterative method for FNA fitting has high accuracy and reliability. Accurate determination of the FNA reduces stress concentration in the proximal femur and decreases the risk of subsequent fracture and non-union of the osteotomy surface.</p>","PeriodicalId":48583,"journal":{"name":"Journal of Hip Preservation Surgery","volume":"12 4","pages":"248-255"},"PeriodicalIF":1.6000,"publicationDate":"2025-05-08","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC12712969/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Hip Preservation Surgery","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1093/jhps/hnaf026","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2025/12/1 0:00:00","PubModel":"eCollection","JCR":"Q3","JCRName":"ORTHOPEDICS","Score":null,"Total":0}
引用次数: 0

Abstract

The femoral neck axis (FNA) is an important reference in femoral neck rotational osteotomy, which is a hip preservation procedure. The purpose of this study was to propose a method for determining the FNA with high accuracy and reliability and to evaluate the effect of FNA determination accuracy on the stress and strain distribution in the proximal femur. Femoral computed tomography data from 50 patients were reconstructed, and the FNA was fitted by the centroid iterative method. The fitting accuracy was evaluated in terms of the distance between the femoral head centre and the FNA. The reliability was assessed by intraclass correlation coefficient (ICC). Stress-strain distributions of the native femur model and rotational osteotomy models with accurate FNA and deviated FNA were simulated by finite element analysis and digital image correlation methods. The distance between the femoral head centre and the FNA was 1.24 ± 0.35 mm. The intra- and interobserver reliability was high, with ICC values of 0.960 and 0.924, respectively. The maximum von Mises stress was 25.76 MPa, 50.82 MPa, and 93.24 MPa for the native femur model, accurate FNA model, and deviated FNA model, respectively. The finite element strain distributions were linearly correlated with digital image correlation results. The centroid iterative method for FNA fitting has high accuracy and reliability. Accurate determination of the FNA reduces stress concentration in the proximal femur and decreases the risk of subsequent fracture and non-union of the osteotomy surface.

旋转截骨术中拟合股骨颈轴的质心迭代法:有限元分析和生物力学研究。
股骨颈轴(FNA)是股骨颈旋转截骨术的重要参考,这是一种髋关节保护手术。本研究旨在提出一种高精度、高可靠性的FNA测定方法,并评价FNA测定精度对股骨近端应力应变分布的影响。对50例患者的股骨ct资料进行重建,采用质心迭代法拟合FNA。根据股骨头中心与FNA之间的距离评估拟合精度。采用类内相关系数(ICC)评价信度。采用有限元分析和数字图像相关方法,模拟了精确FNA和偏离FNA的天然股骨模型和旋转截骨模型的应力应变分布。股骨头中心到FNA的距离为1.24±0.35 mm。观察者内部和观察者之间的信度较高,ICC值分别为0.960和0.924。天然股骨模型、精确FNA模型和偏离FNA模型的最大von Mises应力分别为25.76 MPa、50.82 MPa和93.24 MPa。有限元应变分布与数字图像相关结果呈线性相关。质心迭代法用于FNA拟合具有较高的精度和可靠性。准确测定FNA可减少股骨近端应力集中,降低随后骨折和截骨面不愈合的风险。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
20.00%
发文量
45
审稿时长
12 weeks
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信
小红书