Dosimetric comparison of photon and proton radiosurgery for large arteriovenous malformations.

IF 0.8 Q4 SURGERY
Journal of radiosurgery and SBRT Pub Date : 2025-01-01
Roman L Travis, Travis J Atchley, Martha H Chadband, Michael H Soike, Michael C Dobelbower, Philip G R Schmalz
{"title":"Dosimetric comparison of photon and proton radiosurgery for large arteriovenous malformations.","authors":"Roman L Travis, Travis J Atchley, Martha H Chadband, Michael H Soike, Michael C Dobelbower, Philip G R Schmalz","doi":"","DOIUrl":null,"url":null,"abstract":"<p><strong>Purpose: </strong>Radiosurgery for large arteriovenous malformations (AVMs) is limited by toxicity from dose spillage into normal brain, worsened by larger gradient indices in bigger targets. Proton radiosurgery theoretically reduces integral dose but has greater uncertainty due to robust planning constraints and fewer beam angles. This study evaluates whether pencil beam scanning radiosurgery (PBSR) improves normal brain dosimetry while maintaining comparable target coverage to photon radiosurgery.</p><p><strong>Methods: </strong>The 10 largest AVMs treated with photon radiosurgery at a single institution were re-planned for PBSR in Varian Eclipse. Proton plans incorporated a 2% computed tomography (CT) density correction and 2 mm range uncertainty, with 2-4 beams per institutional practice. Plans prioritized isotoxicity to organs at risk (OARs) before matching target coverage. Dosimetric metrics were compared using a paired <i>t</i>-test.</p><p><strong>Results: </strong>Median AVM size was 36.6 cc (24.3-60.1 cc). All plans prescribed 1750 cGy in one fraction. PBSR had higher gradient indices and reduced target coverage near OARs compared to photon radiosurgery. While PBSR lowered normal brain mean dose and <i>V</i> <sub>5 Gy</sub>, it increased <i>V</i> <sub>12 Gy</sub>, a known predictor of toxicity.</p><p><strong>Conclusions: </strong>PBSR, as planned with current institutional constraints, leads to greater high-dose spill into normal brain and inferior target coverage near OARs. Future improvements in PBSR, such as dual-energy CT, additional beam angles, and LET-based planning, may help mitigate these limitations.</p>","PeriodicalId":16917,"journal":{"name":"Journal of radiosurgery and SBRT","volume":"9 ","pages":"325-330"},"PeriodicalIF":0.8000,"publicationDate":"2025-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC12708002/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of radiosurgery and SBRT","FirstCategoryId":"1085","ListUrlMain":"","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"SURGERY","Score":null,"Total":0}
引用次数: 0

Abstract

Purpose: Radiosurgery for large arteriovenous malformations (AVMs) is limited by toxicity from dose spillage into normal brain, worsened by larger gradient indices in bigger targets. Proton radiosurgery theoretically reduces integral dose but has greater uncertainty due to robust planning constraints and fewer beam angles. This study evaluates whether pencil beam scanning radiosurgery (PBSR) improves normal brain dosimetry while maintaining comparable target coverage to photon radiosurgery.

Methods: The 10 largest AVMs treated with photon radiosurgery at a single institution were re-planned for PBSR in Varian Eclipse. Proton plans incorporated a 2% computed tomography (CT) density correction and 2 mm range uncertainty, with 2-4 beams per institutional practice. Plans prioritized isotoxicity to organs at risk (OARs) before matching target coverage. Dosimetric metrics were compared using a paired t-test.

Results: Median AVM size was 36.6 cc (24.3-60.1 cc). All plans prescribed 1750 cGy in one fraction. PBSR had higher gradient indices and reduced target coverage near OARs compared to photon radiosurgery. While PBSR lowered normal brain mean dose and V 5 Gy, it increased V 12 Gy, a known predictor of toxicity.

Conclusions: PBSR, as planned with current institutional constraints, leads to greater high-dose spill into normal brain and inferior target coverage near OARs. Future improvements in PBSR, such as dual-energy CT, additional beam angles, and LET-based planning, may help mitigate these limitations.

光子与质子放射治疗大动静脉畸形的剂量学比较。
目的:大动静脉畸形(AVMs)的放射治疗受到剂量外溢到正常脑的毒性限制,在更大的靶点上,梯度指数更大而恶化。质子放射手术理论上减少了整体剂量,但由于强大的计划约束和较少的光束角度,具有更大的不确定性。本研究评估了铅笔束扫描放射手术(PBSR)是否能改善正常脑剂量学,同时保持与光子放射手术相当的靶标覆盖。方法:在同一机构进行光子放射治疗的10个最大的AVMs重新计划在Varian Eclipse进行PBSR。质子计划包括2%的计算机断层扫描(CT)密度校正和2mm范围不确定性,每个机构实践2-4束。计划在匹配目标覆盖范围之前优先考虑对危险器官(OARs)的等毒性。剂量学指标采用配对t检验进行比较。结果:中位AVM大小为36.6 cc (24.3-60.1 cc)。所有的计划都规定1750 cGy为一个分数。与光子放射手术相比,PBSR具有更高的梯度指数和更小的目标覆盖。虽然PBSR降低了正常脑平均剂量和v5 Gy,但它增加了v12 Gy,这是已知的毒性预测指标。结论:PBSR,按照目前的制度限制,导致更大的高剂量泄漏到正常大脑和低靶覆盖桨附近。未来对PBSR的改进,如双能CT、附加波束角度和基于let的规划,可能有助于缓解这些限制。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
CiteScore
1.40
自引率
8.30%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信
小红书