Tongtong Tian , liqin Liu , Jun Sun , Jianxiong Fu , Xianfu Luo , Jing Ye , Guangyu Tang
{"title":"Multidelay Pseudocontinuous Arterial Spin Labelling and Conventional Single-delay Pseudocontinuous Arterial Spin Labelling In Nasopharyngeal Carcinoma: Correlation with Dynamic Contrast-enhanced Magnetic Resonance Imaging","authors":"Tongtong Tian , liqin Liu , Jun Sun , Jianxiong Fu , Xianfu Luo , Jing Ye , Guangyu Tang","doi":"10.1053/j.sult.2025.10.004","DOIUrl":null,"url":null,"abstract":"<div><div>The purpose of this prospective study was to investigate the potential correlations among three perfusion methods—multidelay pseudocontinuous arterial spin labelling (MD-PCASL), conventional single-delay pseudocontinuous arterial spin labelling (SD-PCASL), and dynamic contrast-enhanced magnetic resonance imaging (DCE-MRI)—in patients with locoregionally advanced nasopharyngeal carcinoma (ANPC). Forty-seven patients with locoregional ANPC were prospectively recruited. Two observers independently calculated the MD-PCASL parameters, including the ATT-corrected tumour blood flow (c-TBF), arterial transit time (ATT), and arterial tumour blood volume (aTBV); the SD-PCASL parameters, including the noncorrected tumour blood flow (nc-TBF); and the DCE-MRI quantitative parameters, including K<sup>trans</sup>, K<sub>ep</sub>, V<sub>e</sub>, and V<sub>p</sub>. The intra- and interobserver agreement was evaluated via the intraclass correlation coefficient (ICC) and Bland<img>Altman analysis. Relationships between the MD-PCASL, SD-PCASL and DCE-MRI parameters were assessed via Spearman’s rank correlation. The intra- and interobserver reproducibility were excellent, with ICCs ranging from 0.81 to 0.997 and a narrow width of 95% limits of agreement. A good positive correlation was observed between MD-PCASL-related perfusion parameters (c-TBF, aTBV) and DCE-MRI parameters (K<sup>trans</sup>, K<sub>ep</sub>) (Spearman’s rank correlation coefficients: 0.61 to 0.71, p < 0.001). The SD-PCASL (nc-TBF) values were fairly correlated with K<sup>trans</sup> (p<0.001, r = 0.53) and K<sub>ep</sub> (p<0.001, r=0.51). In addition, there was a good correlation between the MD-PCASL-related perfusion parameters (c-TBF) and the SD-PCASL parameters (nc-TBF) (Spearman’s rank correlation coefficients: 0.70, p < 0.001). No correlation was detected between MD-PCASL-related perfusion parameters (c-TBF and aTBV), SD-PCASL (nc-TBF) and DCE-MRI parameters (V<sub>e</sub> and V<sub>p</sub>) (Spearman’s rank correlation coefficients: 0.07 to 0.145, p > 0.05). MD-PCASL multiparametric perfusion, SD-PCASL single-parameter perfusion and quantitative DCE-MRI parameters were correlated and reproducible in the assessment of ANPC. Although SD-PCASL demonstrated a fair correlation with DCE-MRI, the correlation was inferior to that of MD-PCASL with multiple parameters. MD-PCASL, as a noninvasive perfusion imaging tool, may become an alternative for assessing ANPC perfusion levels in the future.</div></div>","PeriodicalId":49541,"journal":{"name":"Seminars in Ultrasound Ct and Mri","volume":"47 1","pages":"Pages 34-45"},"PeriodicalIF":2.5000,"publicationDate":"2026-02-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Seminars in Ultrasound Ct and Mri","FirstCategoryId":"3","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S0887217125000630","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2025/10/25 0:00:00","PubModel":"Epub","JCR":"Q3","JCRName":"RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING","Score":null,"Total":0}
引用次数: 0
Abstract
The purpose of this prospective study was to investigate the potential correlations among three perfusion methods—multidelay pseudocontinuous arterial spin labelling (MD-PCASL), conventional single-delay pseudocontinuous arterial spin labelling (SD-PCASL), and dynamic contrast-enhanced magnetic resonance imaging (DCE-MRI)—in patients with locoregionally advanced nasopharyngeal carcinoma (ANPC). Forty-seven patients with locoregional ANPC were prospectively recruited. Two observers independently calculated the MD-PCASL parameters, including the ATT-corrected tumour blood flow (c-TBF), arterial transit time (ATT), and arterial tumour blood volume (aTBV); the SD-PCASL parameters, including the noncorrected tumour blood flow (nc-TBF); and the DCE-MRI quantitative parameters, including Ktrans, Kep, Ve, and Vp. The intra- and interobserver agreement was evaluated via the intraclass correlation coefficient (ICC) and BlandAltman analysis. Relationships between the MD-PCASL, SD-PCASL and DCE-MRI parameters were assessed via Spearman’s rank correlation. The intra- and interobserver reproducibility were excellent, with ICCs ranging from 0.81 to 0.997 and a narrow width of 95% limits of agreement. A good positive correlation was observed between MD-PCASL-related perfusion parameters (c-TBF, aTBV) and DCE-MRI parameters (Ktrans, Kep) (Spearman’s rank correlation coefficients: 0.61 to 0.71, p < 0.001). The SD-PCASL (nc-TBF) values were fairly correlated with Ktrans (p<0.001, r = 0.53) and Kep (p<0.001, r=0.51). In addition, there was a good correlation between the MD-PCASL-related perfusion parameters (c-TBF) and the SD-PCASL parameters (nc-TBF) (Spearman’s rank correlation coefficients: 0.70, p < 0.001). No correlation was detected between MD-PCASL-related perfusion parameters (c-TBF and aTBV), SD-PCASL (nc-TBF) and DCE-MRI parameters (Ve and Vp) (Spearman’s rank correlation coefficients: 0.07 to 0.145, p > 0.05). MD-PCASL multiparametric perfusion, SD-PCASL single-parameter perfusion and quantitative DCE-MRI parameters were correlated and reproducible in the assessment of ANPC. Although SD-PCASL demonstrated a fair correlation with DCE-MRI, the correlation was inferior to that of MD-PCASL with multiple parameters. MD-PCASL, as a noninvasive perfusion imaging tool, may become an alternative for assessing ANPC perfusion levels in the future.
期刊介绍:
Seminars in Ultrasound, CT and MRI is directed to all physicians involved in the performance and interpretation of ultrasound, computed tomography, and magnetic resonance imaging procedures. It is a timely source for the publication of new concepts and research findings directly applicable to day-to-day clinical practice. The articles describe the performance of various procedures together with the authors'' approach to problems of interpretation.