Evaluating the effect of reactive power injection on power factor and system losses reduction in an optimally sized PV grid-connected solar photovoltaic system

Solar Compass Pub Date : 2026-03-01 Epub Date: 2025-12-01 DOI:10.1016/j.solcom.2025.100149
Edward Dodzi Amekah , Emmanuel Wendsongre Ramde , David Ato Quansah , Elvis Twumasi , Stefanie Meilinger , Thorsten Schneiders
{"title":"Evaluating the effect of reactive power injection on power factor and system losses reduction in an optimally sized PV grid-connected solar photovoltaic system","authors":"Edward Dodzi Amekah ,&nbsp;Emmanuel Wendsongre Ramde ,&nbsp;David Ato Quansah ,&nbsp;Elvis Twumasi ,&nbsp;Stefanie Meilinger ,&nbsp;Thorsten Schneiders","doi":"10.1016/j.solcom.2025.100149","DOIUrl":null,"url":null,"abstract":"<div><div>Although rooftop grid-connected solar PV systems (RGCSPVS) play a crucial role in the global energy transition to mitigate climate change, reactive power imbalance remains a significant power quality challenge, intensifying as the system approaches its optimal penetration limit. This study examines the amount of reactive power an optimally sized GCSPVS can accommodate without exceeding voltage limits. A Python-based dynamic programming approach placed optimally, shunt capacitor (SC) targeting high loads, voltage drops, and losses nodes. The Conditional New Adaptive Foraging Tree Squirrel Search Algorithm (CNAFTSSA) otherwise applied to determine the most effective SC injection locations. In the high-load scenario, 46.20 kVAR of SC injection reduced system losses from 72.36 % to 82.87 %, improving the power factor from 0.51 to 0.69. The high-voltage-drop scenario introduced 10.27 kVAR, reducing losses from 71.57 % to 73.03 % and enhancing the power factor from 0.53 to 0.55. For high-loss nodes, 66.73 kVAR reduced losses from 68.21 % to 82.27 % and improved the power factor from 0.31 to 0.68. The CNAFTSSA scenario injected 65.70 kVAR, reducing losses from 68.34 % to 82.88 % and improving the power factor from 0.31 to 0.67. These results highlight SCs’ role in minimizing losses and enhancing power quality, with the CNAFTSSA approach demonstrating superior performance.</div><div>© 2017 Elsevier Inc. All rights reserved.</div></div>","PeriodicalId":101173,"journal":{"name":"Solar Compass","volume":"17 ","pages":"Article 100149"},"PeriodicalIF":0.0000,"publicationDate":"2026-03-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Solar Compass","FirstCategoryId":"1085","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S277294002500044X","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2025/12/1 0:00:00","PubModel":"Epub","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

Although rooftop grid-connected solar PV systems (RGCSPVS) play a crucial role in the global energy transition to mitigate climate change, reactive power imbalance remains a significant power quality challenge, intensifying as the system approaches its optimal penetration limit. This study examines the amount of reactive power an optimally sized GCSPVS can accommodate without exceeding voltage limits. A Python-based dynamic programming approach placed optimally, shunt capacitor (SC) targeting high loads, voltage drops, and losses nodes. The Conditional New Adaptive Foraging Tree Squirrel Search Algorithm (CNAFTSSA) otherwise applied to determine the most effective SC injection locations. In the high-load scenario, 46.20 kVAR of SC injection reduced system losses from 72.36 % to 82.87 %, improving the power factor from 0.51 to 0.69. The high-voltage-drop scenario introduced 10.27 kVAR, reducing losses from 71.57 % to 73.03 % and enhancing the power factor from 0.53 to 0.55. For high-loss nodes, 66.73 kVAR reduced losses from 68.21 % to 82.27 % and improved the power factor from 0.31 to 0.68. The CNAFTSSA scenario injected 65.70 kVAR, reducing losses from 68.34 % to 82.88 % and improving the power factor from 0.31 to 0.67. These results highlight SCs’ role in minimizing losses and enhancing power quality, with the CNAFTSSA approach demonstrating superior performance.
© 2017 Elsevier Inc. All rights reserved.
评估最优规模光伏并网系统无功功率注入对功率因数和系统损耗降低的影响
尽管屋顶并网太阳能光伏系统(RGCSPVS)在全球能源转型中发挥着至关重要的作用,以缓解气候变化,但无功功率失衡仍然是一个重大的电能质量挑战,随着系统接近其最佳渗透极限,这种挑战会加剧。本研究考察了在不超过电压限制的情况下,最佳尺寸的GCSPVS可以容纳的无功功率量。基于python的动态规划方法对高负载、高电压降和高损耗节点的并联电容(SC)进行了优化。另外,采用条件新自适应觅食树松鼠搜索算法(CNAFTSSA)确定最有效的SC注射位置。在高负荷情况下,46.20 kVAR的SC注入将系统损耗从72.36%降低到82.87%,将功率因数从0.51提高到0.69。高压降方案引入了10.27 kVAR,将损耗从71.57%降低到73.03%,并将功率因数从0.53提高到0.55。对于高损耗节点,66.73 kVAR将损耗从68.21%降低到82.27%,并将功率因数从0.31提高到0.68。CNAFTSSA方案注入65.70 kVAR,将损耗从68.34%降低到82.88%,并将功率因数从0.31提高到0.67。这些结果突出了SCs在最大限度地减少损耗和提高电能质量方面的作用,CNAFTSSA方法显示了卓越的性能。©2017 Elsevier Inc.版权所有。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信
小红书