Accuracy of the hepatorenal index with additional standardized acoustic depth assessment for steatotic liver disease diagnosis

IF 0.8
WFUMB Ultrasound Open Pub Date : 2025-12-01 Epub Date: 2025-12-11 DOI:10.1016/j.wfumbo.2025.100083
Maksym Zhaivoronok , Oleg Dynnyk , Natalia Deresh , Ludovico Abenavoli , Nazarii Kobyliak
{"title":"Accuracy of the hepatorenal index with additional standardized acoustic depth assessment for steatotic liver disease diagnosis","authors":"Maksym Zhaivoronok ,&nbsp;Oleg Dynnyk ,&nbsp;Natalia Deresh ,&nbsp;Ludovico Abenavoli ,&nbsp;Nazarii Kobyliak","doi":"10.1016/j.wfumbo.2025.100083","DOIUrl":null,"url":null,"abstract":"<div><div>Metabolic dysfunction–associated steatotic liver disease (MASLD) is the most common pathology among all chronic liver diseases. In the early stages, steatotic liver disease (SLD) has an asymptomatic clinical course, which makes it difficult to detect. Ultrasound (US) is a safe, noninvasive, first-line method for SLD diagnosis, including determination of the hepatorenal index (HRI). The HRI is a convenient, semiquantitative, noninvasive method for SLD diagnostics. This case‒control observational study aimed to compare the diagnostic accuracy of conventional HRI and HRI with that of additional standardized acoustic depth assessments for SLD using MRI-PDFF as a reference.</div></div><div><h3>Materials and methods</h3><div>A total of 161 patients aged 18–67 years were examined. Patients &gt;18 years of age were referred for MRI-PDFF assessment of suspected liver pathology. The only exclusion criterion was an absent or invalid HRI or MRI-PDFF.</div></div><div><h3>Results</h3><div>The quality of the HRI diagnostic model with a baseline (BL) was slightly higher, with an AUROC of 0.917 (p &lt; 0.001), and the sensitivity and specificity were 83.0 % and 95.9 %, respectively. The AUROC for HRI without BL was 0.862 (p &lt; 0.001) with sensitivity and specificity of 84.2 % and 85.1 %, respectively. Bland‒Altman analysis of the comparison of HRIs with and without BL revealed an error of 0.007 (p &lt; 0.05).</div></div><div><h3>Conclusions</h3><div>Our study revealed that it is better to determine the semiquantitative HRI using a reference BL at a standardized uniform depth to preserve acoustic attenuation effects. The advantages of US SLD evaluation for HRI with BL are simplicity of performance and the accuracy of acoustic echogenicity measurements.</div></div>","PeriodicalId":101281,"journal":{"name":"WFUMB Ultrasound Open","volume":"3 2","pages":"Article 100083"},"PeriodicalIF":0.8000,"publicationDate":"2025-12-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"WFUMB Ultrasound Open","FirstCategoryId":"1085","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S2949668325000059","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2025/12/11 0:00:00","PubModel":"Epub","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

Metabolic dysfunction–associated steatotic liver disease (MASLD) is the most common pathology among all chronic liver diseases. In the early stages, steatotic liver disease (SLD) has an asymptomatic clinical course, which makes it difficult to detect. Ultrasound (US) is a safe, noninvasive, first-line method for SLD diagnosis, including determination of the hepatorenal index (HRI). The HRI is a convenient, semiquantitative, noninvasive method for SLD diagnostics. This case‒control observational study aimed to compare the diagnostic accuracy of conventional HRI and HRI with that of additional standardized acoustic depth assessments for SLD using MRI-PDFF as a reference.

Materials and methods

A total of 161 patients aged 18–67 years were examined. Patients >18 years of age were referred for MRI-PDFF assessment of suspected liver pathology. The only exclusion criterion was an absent or invalid HRI or MRI-PDFF.

Results

The quality of the HRI diagnostic model with a baseline (BL) was slightly higher, with an AUROC of 0.917 (p < 0.001), and the sensitivity and specificity were 83.0 % and 95.9 %, respectively. The AUROC for HRI without BL was 0.862 (p < 0.001) with sensitivity and specificity of 84.2 % and 85.1 %, respectively. Bland‒Altman analysis of the comparison of HRIs with and without BL revealed an error of 0.007 (p < 0.05).

Conclusions

Our study revealed that it is better to determine the semiquantitative HRI using a reference BL at a standardized uniform depth to preserve acoustic attenuation effects. The advantages of US SLD evaluation for HRI with BL are simplicity of performance and the accuracy of acoustic echogenicity measurements.
肝肾指数与附加的标准化声学深度评估在脂肪肝诊断中的准确性
代谢功能障碍相关脂肪变性肝病(MASLD)是所有慢性肝病中最常见的病理。在早期阶段,脂肪变性肝病(SLD)有一个无症状的临床过程,这使得它很难被发现。超声(US)是一种安全、无创、用于SLD诊断的一线方法,包括测定肝肾指数(HRI)。HRI是一种方便、半定量、无创的SLD诊断方法。本病例对照观察性研究旨在比较常规HRI和HRI与附加的标准化声深度评估对SLD的诊断准确性,并以MRI-PDFF为参考。材料与方法对161例18 ~ 67岁的患者进行检查。18岁的患者接受MRI-PDFF评估疑似肝脏病理。唯一的排除标准是HRI或MRI-PDFF缺失或无效。结果有基线(BL)的HRI诊断模型质量略高,AUROC为0.917 (p < 0.001),敏感性和特异性分别为83.0%和95.9%。无BL的HRI AUROC为0.862 (p < 0.001),敏感性为84.2%,特异性为85.1%。Bland-Altman分析显示,合并和不合并BL的HRIs的误差为0.007 (p < 0.05)。结论采用标准均匀深度的参考声压线来确定半定量声压线较好,可保留声衰减效果。US SLD评价HRI与BL的优点是性能简单,声回波测量准确。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信
小红书