A Simple and Cost-Effective Method for Condition Monitoring of Inverter DC-Link Film Capacitors Based on Capacitance Variation

IF 3.8 Q1 ENGINEERING, ELECTRICAL & ELECTRONIC
Seyed Hossein Aleyasin;Fausto Stella;Radu Bojoi;Enrico Vico;Chaohui Liu
{"title":"A Simple and Cost-Effective Method for Condition Monitoring of Inverter DC-Link Film Capacitors Based on Capacitance Variation","authors":"Seyed Hossein Aleyasin;Fausto Stella;Radu Bojoi;Enrico Vico;Chaohui Liu","doi":"10.1109/OJIA.2025.3635891","DOIUrl":null,"url":null,"abstract":"DC-link capacitors are among the most critical components in traction inverters, with a high likelihood of failure. Effective condition monitoring (CM) of these capacitors is crucial for improving converter reliability and preventing catastrophic failures. This article presents a cost-effective and reliable methodology for evaluating the health state of film capacitors used as dc-link in traction inverters. The proposed approach uses a controlled discharge test to track capacitance variations over time, which can be used as an indirect indicator of the capacitor’s health state. Key advantages of this technique include the minimal additional component requirements for cost efficiency, strong noise immunity, and high precision. Furthermore, the proposed aging detection test can be fully automated without requiring the removal of the capacitor or modifications to the converter’s power stage. Experimental results are provided to validate the effectiveness of the proposed solution.","PeriodicalId":100629,"journal":{"name":"IEEE Open Journal of Industry Applications","volume":"6 ","pages":"867-876"},"PeriodicalIF":3.8000,"publicationDate":"2025-11-24","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://ieeexplore.ieee.org/stamp/stamp.jsp?tp=&arnumber=11266941","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"IEEE Open Journal of Industry Applications","FirstCategoryId":"1085","ListUrlMain":"https://ieeexplore.ieee.org/document/11266941/","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"ENGINEERING, ELECTRICAL & ELECTRONIC","Score":null,"Total":0}
引用次数: 0

Abstract

DC-link capacitors are among the most critical components in traction inverters, with a high likelihood of failure. Effective condition monitoring (CM) of these capacitors is crucial for improving converter reliability and preventing catastrophic failures. This article presents a cost-effective and reliable methodology for evaluating the health state of film capacitors used as dc-link in traction inverters. The proposed approach uses a controlled discharge test to track capacitance variations over time, which can be used as an indirect indicator of the capacitor’s health state. Key advantages of this technique include the minimal additional component requirements for cost efficiency, strong noise immunity, and high precision. Furthermore, the proposed aging detection test can be fully automated without requiring the removal of the capacitor or modifications to the converter’s power stage. Experimental results are provided to validate the effectiveness of the proposed solution.
一种基于电容变化的逆变器直流电容状态监测方法
直流链路电容器是牵引逆变器中最关键的部件之一,故障的可能性很高。有效的状态监测对提高变换器的可靠性和防止灾难性故障至关重要。本文提出了一种经济可靠的评价牵引逆变器直流链路用薄膜电容器健康状态的方法。所提出的方法使用受控放电测试来跟踪电容随时间的变化,这可以用作电容器健康状态的间接指示器。该技术的主要优点包括成本效率最低的额外组件需求,强抗噪性和高精度。此外,提出的老化检测测试可以完全自动化,而不需要去除电容器或修改转换器的功率级。实验结果验证了该方法的有效性。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
CiteScore
13.50
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信
小红书