{"title":"[Reoperation for Pseudoaneurysm Late After Bentall Procedure:Report of a Case].","authors":"Hiroyuki Yamada, Yoshiki Onuki, Yuji Kamikawa, Naohiro Shimada","doi":"","DOIUrl":null,"url":null,"abstract":"<p><p>We report a case of reoperation for pseudoaneurysm late after Bentall procedure. A 61-year-old man who had undergone Bentall procedure eight years previously was found to have fluid collection around the graft on routine computed tomography (CT) follow-up. Contrast-enhanced CT revealed extravasation of contrast medium, and he was diagnosed with a pseudoaneurysm of the aorta. During surgery, extracorporeal circulation was temporarily stopped prior to resternotomy to avoid massive hemorrhage. The pseudoaneurysm was due to dehiscence of 4/5 circumference of the proximal suture line. The previous composite graft was removed and replaced with a new graft. The patient recovered well and was discharged on postoperative day 12. This case illustrates the importance of regular imaging surveillance after aortic root replacement and careful surgical planning for reoperations to prevent catastrophic bleeding complications.</p>","PeriodicalId":17841,"journal":{"name":"Kyobu geka. The Japanese journal of thoracic surgery","volume":"78 13","pages":"1126-1129"},"PeriodicalIF":0.0000,"publicationDate":"2025-12-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Kyobu geka. The Japanese journal of thoracic surgery","FirstCategoryId":"1085","ListUrlMain":"","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"Medicine","Score":null,"Total":0}
引用次数: 0
Abstract
We report a case of reoperation for pseudoaneurysm late after Bentall procedure. A 61-year-old man who had undergone Bentall procedure eight years previously was found to have fluid collection around the graft on routine computed tomography (CT) follow-up. Contrast-enhanced CT revealed extravasation of contrast medium, and he was diagnosed with a pseudoaneurysm of the aorta. During surgery, extracorporeal circulation was temporarily stopped prior to resternotomy to avoid massive hemorrhage. The pseudoaneurysm was due to dehiscence of 4/5 circumference of the proximal suture line. The previous composite graft was removed and replaced with a new graft. The patient recovered well and was discharged on postoperative day 12. This case illustrates the importance of regular imaging surveillance after aortic root replacement and careful surgical planning for reoperations to prevent catastrophic bleeding complications.