30 - Assesing the reliability of artificial intelligence-based automatic digital model analysis compared to manual system

IF 3.5 Q1 DENTISTRY, ORAL SURGERY & MEDICINE
Zeynep Beyçe Karaman , Kaan Kahya , Can Arslan , Derya Çakan
{"title":"30 - Assesing the reliability of artificial intelligence-based automatic digital model analysis compared to manual system","authors":"Zeynep Beyçe Karaman ,&nbsp;Kaan Kahya ,&nbsp;Can Arslan ,&nbsp;Derya Çakan","doi":"10.1016/j.ejwf.2025.07.034","DOIUrl":null,"url":null,"abstract":"<div><div>In orthodontic treatment planning, model analysis plays a crucial role in evaluating the patient's dental and skeletal structure. Measurements and analyses are essential for understanding the severity of malocclusion and developing individualized treatment plans to achieve functional and aesthetic alignment. The accuracy of these measurements directly impacts treatment outcomes and patient satisfaction. Technological advancements have significantly influenced orthodontic model analysis. Within these digital systems, measurements can be obtained through manual segmentation of STL files uploaded into a software. With the advent of artificial intelligence (AI), software now enables automatic segmentation, offering precise measurements for model analysis parameters. AI-based automatic digital model analysis represents a paradigm shift in orthodontics, utilizing advanced algorithms to analyze digital models with greater speed, efficiency, and consistency than traditional methods. These systems promise transformative improvements but also raise questions regarding their diagnostic accuracy and clinical utility. Evaluating the differences between digital and manual methods is essential to ensure the reliability and safety of patient care. This study evaluates the accuracy and reliability of AI-supported digital model analysis compared to auto-segmented digital (AD), manual digital (MD), and manual plaster (MP) methods. Parameters such as tooth segmentation, measurement accuracy, and analysis efficiency are assessed. There remains a significant gap in the literature regarding studies that compare digital systems in their own methods of analysis options. Most of the digital software systems include manual segmentation and automatic segmentation options. The majority of the studies tend to compare digital systems to conventional plaster models, focusing on the differences and similarities between the two techniques. However, there is a lack of comprehensive analysis investigating how various digital methods perform relative to one another, without incorporating or relying on comparisons to traditional plaster model techniques. This gap highlights the need for studies that focus solely on the intra-domain evaluation of digital systems, which could provide deeper insights into their precision and reliability under different diagnostic and operational conditions. Twenty-four individuals, comprising 8 males and 16 females (19.5± 6,05 years of age), with all permanent teeth and mild to moderate crowding were selected. Linear measurements were made with a digital caliper on the plaster models of the selected patients. The digital models were manually and automatically segmented and measured using a Software. Mesiodistal tooth dimensions, arch widths were measured, and Bolton analysis was performed. Repeated measurements and statistical analysis show that all methods give consistent results. Low standard deviations and narrow confidence intervals indicate that each system is reliable, but that some methods may be more precise. In comparing the methods, a significant difference was found when examining the size of teeth other than premolars (p&lt;0.05). There was no statistically significant difference between AD and MD systems in parameters such as arch length deficiency, and Bolton discrepancy. (p&gt;0.05). The AD and MD methods produced consistent measurement results. The MP method showed a higher probability of error due to conventional processing steps. Enhancing digital methods with deep learning can further improve AI-based AD accuracy, bringing it closer to the MD method.</div></div>","PeriodicalId":43456,"journal":{"name":"Journal of the World Federation of Orthodontists","volume":"14 6","pages":"Page 408"},"PeriodicalIF":3.5000,"publicationDate":"2025-12-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of the World Federation of Orthodontists","FirstCategoryId":"1085","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S221244382500089X","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2025/12/9 0:00:00","PubModel":"Epub","JCR":"Q1","JCRName":"DENTISTRY, ORAL SURGERY & MEDICINE","Score":null,"Total":0}
引用次数: 0

Abstract

In orthodontic treatment planning, model analysis plays a crucial role in evaluating the patient's dental and skeletal structure. Measurements and analyses are essential for understanding the severity of malocclusion and developing individualized treatment plans to achieve functional and aesthetic alignment. The accuracy of these measurements directly impacts treatment outcomes and patient satisfaction. Technological advancements have significantly influenced orthodontic model analysis. Within these digital systems, measurements can be obtained through manual segmentation of STL files uploaded into a software. With the advent of artificial intelligence (AI), software now enables automatic segmentation, offering precise measurements for model analysis parameters. AI-based automatic digital model analysis represents a paradigm shift in orthodontics, utilizing advanced algorithms to analyze digital models with greater speed, efficiency, and consistency than traditional methods. These systems promise transformative improvements but also raise questions regarding their diagnostic accuracy and clinical utility. Evaluating the differences between digital and manual methods is essential to ensure the reliability and safety of patient care. This study evaluates the accuracy and reliability of AI-supported digital model analysis compared to auto-segmented digital (AD), manual digital (MD), and manual plaster (MP) methods. Parameters such as tooth segmentation, measurement accuracy, and analysis efficiency are assessed. There remains a significant gap in the literature regarding studies that compare digital systems in their own methods of analysis options. Most of the digital software systems include manual segmentation and automatic segmentation options. The majority of the studies tend to compare digital systems to conventional plaster models, focusing on the differences and similarities between the two techniques. However, there is a lack of comprehensive analysis investigating how various digital methods perform relative to one another, without incorporating or relying on comparisons to traditional plaster model techniques. This gap highlights the need for studies that focus solely on the intra-domain evaluation of digital systems, which could provide deeper insights into their precision and reliability under different diagnostic and operational conditions. Twenty-four individuals, comprising 8 males and 16 females (19.5± 6,05 years of age), with all permanent teeth and mild to moderate crowding were selected. Linear measurements were made with a digital caliper on the plaster models of the selected patients. The digital models were manually and automatically segmented and measured using a Software. Mesiodistal tooth dimensions, arch widths were measured, and Bolton analysis was performed. Repeated measurements and statistical analysis show that all methods give consistent results. Low standard deviations and narrow confidence intervals indicate that each system is reliable, but that some methods may be more precise. In comparing the methods, a significant difference was found when examining the size of teeth other than premolars (p<0.05). There was no statistically significant difference between AD and MD systems in parameters such as arch length deficiency, and Bolton discrepancy. (p>0.05). The AD and MD methods produced consistent measurement results. The MP method showed a higher probability of error due to conventional processing steps. Enhancing digital methods with deep learning can further improve AI-based AD accuracy, bringing it closer to the MD method.
评估基于人工智能的自动数字模型分析与手动系统的可靠性
在正畸治疗计划中,模型分析在评估患者牙齿和骨骼结构方面起着至关重要的作用。测量和分析对于了解错牙合的严重程度和制定个性化的治疗计划以实现功能和美学对齐是必不可少的。这些测量的准确性直接影响治疗结果和患者满意度。技术进步对正畸模型分析产生了重大影响。在这些数字系统中,可以通过手动分割上传到软件中的STL文件来获得测量值。随着人工智能(AI)的出现,软件现在可以自动分割,为模型分析参数提供精确的测量。基于人工智能的自动数字模型分析代表了正畸学的范式转变,利用先进的算法来分析数字模型,比传统方法具有更高的速度、效率和一致性。这些系统有望带来革命性的改进,但也提出了有关其诊断准确性和临床实用性的问题。评估数字和手动方法之间的差异对于确保患者护理的可靠性和安全性至关重要。与自动分割数字(AD)、手动数字(MD)和手动石膏(MP)方法相比,本研究评估了人工智能支持的数字模型分析的准确性和可靠性。对牙齿分割、测量精度和分析效率等参数进行了评估。在文献中,关于比较数字系统自己的分析选择方法的研究仍然存在显著的差距。大多数数字软件系统包括手动分割和自动分割选项。大多数研究倾向于将数字系统与传统的石膏模型进行比较,重点关注两种技术之间的异同。然而,缺乏全面的分析,调查各种数字方法相对于彼此的表现,而不纳入或依赖于传统石膏模型技术的比较。这一差距凸显了只关注数字系统域内评估的研究需求,这可以更深入地了解它们在不同诊断和操作条件下的精度和可靠性。选取24例,男8例,女16例,年龄19.5±6.05岁,均为恒牙,轻度至中度拥挤。用数字卡尺对所选患者的石膏模型进行线性测量。采用软件对数字模型进行手动和自动分割和测量。测量中远端牙尺寸、牙弓宽度,进行博尔顿分析。反复测量和统计分析表明,所有方法的结果一致。低标准偏差和窄置信区间表明每个系统是可靠的,但有些方法可能更精确。在检查前磨牙以外的牙齿大小时,两种方法的差异有统计学意义(p < 0.05)。AD和MD系统在足弓长度不足、博尔顿差异等参数上无统计学差异。(p> 0.05)。AD法和MD法测量结果一致。由于传统的加工步骤,MP方法显示出较高的误差概率。用深度学习增强数字方法可以进一步提高基于ai的AD精度,使其更接近MD方法。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
Journal of the World Federation of Orthodontists
Journal of the World Federation of Orthodontists DENTISTRY, ORAL SURGERY & MEDICINE-
CiteScore
3.80
自引率
4.80%
发文量
34
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信
小红书