Not all boxes are equal: Investigation of parameters affecting PM2.5 particle removal by the Corsi-Rosenthal box

IF 2.9 3区 环境科学与生态学 Q2 ENGINEERING, CHEMICAL
Journal of Aerosol Science Pub Date : 2026-02-01 Epub Date: 2025-12-06 DOI:10.1016/j.jaerosci.2025.106731
Antonio Baratta, Taewon T. Han, Gediminas Mainelis
{"title":"Not all boxes are equal: Investigation of parameters affecting PM2.5 particle removal by the Corsi-Rosenthal box","authors":"Antonio Baratta,&nbsp;Taewon T. Han,&nbsp;Gediminas Mainelis","doi":"10.1016/j.jaerosci.2025.106731","DOIUrl":null,"url":null,"abstract":"<div><div>The Corsi-Rosenthal (C-R) box has gained widespread popularity as an affordable, do-it-yourself air cleaner designed to improve indoor air quality. Despite its rapid adoption, limited studies have evaluated how different operational and experimental variables affect the C-R box's efficiency. This study investigated the Clean Air Delivery Rate (CADR) of the C-R box as a function of filter rating, its electret enhancement, measurement interval, location, and type of measurement devices, and additional air mixing when removing PM<sub>2.5</sub> sodium chloride (NaCl) or Arizona Road Dust (ARD) particles in a 3024 ft<sup>3</sup> (∼86 m<sup>3</sup>) room. Based on measurements by a research-grade MiniWRAS (1371, DURAG Group, Hamburg, Germany), the C-R box with four 2-inch MERV-13 filters achieved a CADR of 358.56 ± 10.58 cubic feet per minute (cfm) at its highest fan speed, outperforming MERV-8 filters (209.93 ± 9.30 cfm) by 71 % despite only a 41 % increase in filter cost. MERV-13 filters with an electret designation did not improve CADR compared to plain MERV-13 filters. When challenged with ARD particles, the C-R box achieved a CADR of 416.60 ± 8.31 cfm: 15 % higher compared to NaCl particles. We also observed that moving the C-R box farther away from the measurement devices (140 inches vs 65 inches) led to a decrease in CADR by ∼8 %. However, using additional mixing fans helped improve CADR in the room's corners by up to 21 %. Comparison of CADR determined by an out-of-the-box consumer-grade AirVisual monitor with MiniWRAS showed that the AirVisual yielded the same trends, albeit at a ∼14 % higher CADR. Our investigation of variables affecting the measured C-R box's CADR will help optimize its performance and improve data comparison across studies. We also demonstrate that consumer-grade monitors are a viable option in investigating the performance of air cleaners, especially their localized performance.</div></div>","PeriodicalId":14880,"journal":{"name":"Journal of Aerosol Science","volume":"192 ","pages":"Article 106731"},"PeriodicalIF":2.9000,"publicationDate":"2026-02-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Aerosol Science","FirstCategoryId":"93","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S0021850225002083","RegionNum":3,"RegionCategory":"环境科学与生态学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2025/12/6 0:00:00","PubModel":"Epub","JCR":"Q2","JCRName":"ENGINEERING, CHEMICAL","Score":null,"Total":0}
引用次数: 0

Abstract

The Corsi-Rosenthal (C-R) box has gained widespread popularity as an affordable, do-it-yourself air cleaner designed to improve indoor air quality. Despite its rapid adoption, limited studies have evaluated how different operational and experimental variables affect the C-R box's efficiency. This study investigated the Clean Air Delivery Rate (CADR) of the C-R box as a function of filter rating, its electret enhancement, measurement interval, location, and type of measurement devices, and additional air mixing when removing PM2.5 sodium chloride (NaCl) or Arizona Road Dust (ARD) particles in a 3024 ft3 (∼86 m3) room. Based on measurements by a research-grade MiniWRAS (1371, DURAG Group, Hamburg, Germany), the C-R box with four 2-inch MERV-13 filters achieved a CADR of 358.56 ± 10.58 cubic feet per minute (cfm) at its highest fan speed, outperforming MERV-8 filters (209.93 ± 9.30 cfm) by 71 % despite only a 41 % increase in filter cost. MERV-13 filters with an electret designation did not improve CADR compared to plain MERV-13 filters. When challenged with ARD particles, the C-R box achieved a CADR of 416.60 ± 8.31 cfm: 15 % higher compared to NaCl particles. We also observed that moving the C-R box farther away from the measurement devices (140 inches vs 65 inches) led to a decrease in CADR by ∼8 %. However, using additional mixing fans helped improve CADR in the room's corners by up to 21 %. Comparison of CADR determined by an out-of-the-box consumer-grade AirVisual monitor with MiniWRAS showed that the AirVisual yielded the same trends, albeit at a ∼14 % higher CADR. Our investigation of variables affecting the measured C-R box's CADR will help optimize its performance and improve data comparison across studies. We also demonstrate that consumer-grade monitors are a viable option in investigating the performance of air cleaners, especially their localized performance.
并不是所有的盒子都是一样的:用Corsi-Rosenthal盒子研究影响PM2.5颗粒去除的参数
Corsi-Rosenthal (C-R)盒子作为一种经济实惠的,自己动手的空气净化器,旨在改善室内空气质量,已经获得了广泛的欢迎。尽管它被迅速采用,但有限的研究评估了不同的操作和实验变量如何影响C-R箱的效率。本研究调查了C-R箱的清洁空气输送率(CADR)作为过滤器等级、驻极体增强、测量间隔、位置和测量设备类型的函数,以及在3024平方英尺(~ 86立方米)的房间中去除PM2.5氯化钠(NaCl)或亚利桑那道路粉尘(ARD)颗粒时的额外空气混合。根据研究级MiniWRAS (1371, DURAG Group, Hamburg, Germany)的测量结果,配备4个2英寸MERV-13过滤器的C-R箱在最高风扇转速下的CADR为358.56±10.58立方英尺/分钟(cfm),比MERV-8过滤器(209.93±9.30 cfm)高出了71 %,而过滤器成本仅增加了41 %。与普通MERV-13滤波器相比,带有驻极体标识的MERV-13滤波器没有提高CADR。当用ARD粒子激发时,C-R盒的CADR为416.60±8.31 cfm,比NaCl粒子高15%。我们还观察到,将C-R盒远离测量装置(140英寸vs 65英寸)导致CADR降低约8%。然而,使用额外的混合风扇有助于提高房间角落的CADR高达21%。将即用的消费级AirVisual监测仪与MiniWRAS测定的CADR进行比较,结果表明,AirVisual产生了相同的趋势,尽管CADR高出约14%。我们对影响测量C-R盒CADR的变量的研究将有助于优化其性能并改进研究间的数据比较。我们还证明,在调查空气净化器的性能,特别是其本地化性能时,消费级显示器是一个可行的选择。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
Journal of Aerosol Science
Journal of Aerosol Science 环境科学-工程:化工
CiteScore
8.80
自引率
8.90%
发文量
127
审稿时长
35 days
期刊介绍: Founded in 1970, the Journal of Aerosol Science considers itself the prime vehicle for the publication of original work as well as reviews related to fundamental and applied aerosol research, as well as aerosol instrumentation. Its content is directed at scientists working in engineering disciplines, as well as physics, chemistry, and environmental sciences. The editors welcome submissions of papers describing recent experimental, numerical, and theoretical research related to the following topics: 1. Fundamental Aerosol Science. 2. Applied Aerosol Science. 3. Instrumentation & Measurement Methods.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信
小红书