Configurable γ Photon Spectrometer to Enable Precision Radioguided Tumor Resection

IF 4.9
Rahul Lall;Youngho Seo;Ali M. Niknejad;Mekhail Anwar
{"title":"Configurable γ Photon Spectrometer to Enable Precision Radioguided Tumor Resection","authors":"Rahul Lall;Youngho Seo;Ali M. Niknejad;Mekhail Anwar","doi":"10.1109/TBCAS.2025.3625580","DOIUrl":null,"url":null,"abstract":"Surgical tumor resection aims to remove all cancer cells in the tumor margin and at centimeter-scale depths below the tissue surface. During surgery, microscopic clusters of disease are intraoperatively difficult to visualize and are often left behind, significantly increasing the risk of cancer recurrence. Radioguided surgery (RGS) has shown the ability to selectively tag cancer cells with gamma (γ) photon emitting radioisotopes to identify them, but require a mm-scale γ photon spectrometer to localize the position of these cells in the tissue margin (i.e., a function of incident γ photon energy) with high specificity. Here we present a 9.9 mm<sup>2</sup> integrated circuit (IC)-based γ spectrometer implemented in 180 nm CMOS, to enable the measurement of single γ photons and their incident energy with sub-keV energy resolution. We use small <inline-formula><tex-math>$2 \\times 2$</tex-math></inline-formula> µm reverse-biased diodes that have low depletion region capacitance, and therefore produce millivolt-scale voltage signals in response to the small charge generated by incident γ photons. A low-power energy spectrometry method is implemented by measuring the decay time it takes for the generated voltage signal to settle back to DC after a γ detection event, instead of measuring the voltage drop directly. This spectrometry method is implemented in three different pixel architectures that allow for configurable pixel sensitivity, energy-resolution, and energy dynamic range based on the widely heterogenous surgical and patient presentation in RGS. The spectrometer was tested with three common γ-emitting radioisotopes (<sup>64</sup>Cu, <sup>133</sup>Ba, <sup>177</sup>Lu), and is able to resolve activities down to 1 µCi with sub-keV energy resolution and 1.315 MeV energy dynamic range, using 5-minute acquisitions.","PeriodicalId":94031,"journal":{"name":"IEEE transactions on biomedical circuits and systems","volume":"19 6","pages":"1048-1064"},"PeriodicalIF":4.9000,"publicationDate":"2025-12-05","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"IEEE transactions on biomedical circuits and systems","FirstCategoryId":"1085","ListUrlMain":"https://ieeexplore.ieee.org/document/11278830/","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

Surgical tumor resection aims to remove all cancer cells in the tumor margin and at centimeter-scale depths below the tissue surface. During surgery, microscopic clusters of disease are intraoperatively difficult to visualize and are often left behind, significantly increasing the risk of cancer recurrence. Radioguided surgery (RGS) has shown the ability to selectively tag cancer cells with gamma (γ) photon emitting radioisotopes to identify them, but require a mm-scale γ photon spectrometer to localize the position of these cells in the tissue margin (i.e., a function of incident γ photon energy) with high specificity. Here we present a 9.9 mm2 integrated circuit (IC)-based γ spectrometer implemented in 180 nm CMOS, to enable the measurement of single γ photons and their incident energy with sub-keV energy resolution. We use small $2 \times 2$ µm reverse-biased diodes that have low depletion region capacitance, and therefore produce millivolt-scale voltage signals in response to the small charge generated by incident γ photons. A low-power energy spectrometry method is implemented by measuring the decay time it takes for the generated voltage signal to settle back to DC after a γ detection event, instead of measuring the voltage drop directly. This spectrometry method is implemented in three different pixel architectures that allow for configurable pixel sensitivity, energy-resolution, and energy dynamic range based on the widely heterogenous surgical and patient presentation in RGS. The spectrometer was tested with three common γ-emitting radioisotopes (64Cu, 133Ba, 177Lu), and is able to resolve activities down to 1 µCi with sub-keV energy resolution and 1.315 MeV energy dynamic range, using 5-minute acquisitions.
可配置γ光子光谱仪,实现精确的放射引导肿瘤切除。
外科肿瘤切除术的目的是切除肿瘤边缘和组织表面以下厘米级深度的所有癌细胞。在手术过程中,显微镜下的病变团在术中很难观察到,并且经常被遗漏,这大大增加了癌症复发的风险。放射引导手术(RGS)已经显示出用发射伽马(γ)光子的放射性同位素选择性标记癌细胞以识别它们的能力,但需要毫米尺度的γ光子光谱仪以高特异性定位这些细胞在组织边缘的位置(即入射γ光子能量的函数)。在这里,我们提出了一个9.9 mm2集成电路(IC)为基础的γ能谱仪实现在180纳米CMOS,能够测量单个γ光子及其入射能量的亚键能量分辨率。我们使用小的2 × 2 μm反向偏置二极管,具有低耗尽区电容,因此产生毫伏级电压信号,以响应入射γ光子产生的小电荷。通过测量γ探测事件后产生的电压信号回落到直流电所需的衰减时间,实现了一种低功率能谱法,而不是直接测量电压降。该光谱法在三种不同的像素架构中实现,允许基于RGS中广泛异质的手术和患者表现来配置像素灵敏度、能量分辨率和能量动态范围。该光谱仪用三种常见的γ辐射同位素(64Cu、133Ba、177Lu)进行了测试,能够以亚kev的能量分辨率和1.315 MeV的能量动态范围分辨低至1 μCi的活动,采集时间为5分钟。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信
小红书