Highly stable direct-printed polyazulene-based miniaturized electrode for pH analysis in human body fluids

IF 4.9 2区 医学 Q1 ENGINEERING, BIOMEDICAL
Biocybernetics and Biomedical Engineering Pub Date : 2026-01-01 Epub Date: 2025-12-05 DOI:10.1016/j.bbe.2025.11.008
Agnieszka Paziewska-Nowak , Marcin Urbanowicz , Marek Dawgul , Kornelia Bobrowska , Anna Sołdatowska , Marcin Ekman , Dorota G. Pijanowska
{"title":"Highly stable direct-printed polyazulene-based miniaturized electrode for pH analysis in human body fluids","authors":"Agnieszka Paziewska-Nowak ,&nbsp;Marcin Urbanowicz ,&nbsp;Marek Dawgul ,&nbsp;Kornelia Bobrowska ,&nbsp;Anna Sołdatowska ,&nbsp;Marcin Ekman ,&nbsp;Dorota G. Pijanowska","doi":"10.1016/j.bbe.2025.11.008","DOIUrl":null,"url":null,"abstract":"<div><div>pH monitoring in biological fluids plays a critical role in clinical diagnostics and therapeutic management. This study presents a novel solid-contact pH electrode fabricated using a direct-printed (DP) graphite (Gr) electrode on a flexible substrate, followed by an electropolymerized hydrophobic polyazulene (pAz) transducing layer, and an ion-selective membrane (ISM). The pH electrode was paired with a miniaturized solid-state Ag/AgCl reference electrode incorporating a photopolymerized PVA-KCl matrix. The miniaturized reference electrode exhibited excellent potential stability (±2.5 mV across pH 2–11), and minimal signal drift (10  µV/h). The miniaturized pH electrode exhibited a sensitivity of 55.7 mV/dec, with a rapid response time of 6 s (vs. Orion™ ROSS Ultra™ reference electrode) or 42 s (vs. miniaturized solid-state reference electrode) and a linear response over the pH range of 2–10. The pH electrode demonstrated excellent analytical performance in diverse biological fluids, including urine, serum, saliva, and surgical drain fluid, closely matching the performance of a laboratory-grade combined glass pH electrode. These results underscore the potential of the proposed platform as a reliable and technologically scalable tool for real-time pH assessment in biomedical applications.</div></div>","PeriodicalId":55381,"journal":{"name":"Biocybernetics and Biomedical Engineering","volume":"46 1","pages":"Pages 40-49"},"PeriodicalIF":4.9000,"publicationDate":"2026-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Biocybernetics and Biomedical Engineering","FirstCategoryId":"5","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S0208521625000890","RegionNum":2,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2025/12/5 0:00:00","PubModel":"Epub","JCR":"Q1","JCRName":"ENGINEERING, BIOMEDICAL","Score":null,"Total":0}
引用次数: 0

Abstract

pH monitoring in biological fluids plays a critical role in clinical diagnostics and therapeutic management. This study presents a novel solid-contact pH electrode fabricated using a direct-printed (DP) graphite (Gr) electrode on a flexible substrate, followed by an electropolymerized hydrophobic polyazulene (pAz) transducing layer, and an ion-selective membrane (ISM). The pH electrode was paired with a miniaturized solid-state Ag/AgCl reference electrode incorporating a photopolymerized PVA-KCl matrix. The miniaturized reference electrode exhibited excellent potential stability (±2.5 mV across pH 2–11), and minimal signal drift (10  µV/h). The miniaturized pH electrode exhibited a sensitivity of 55.7 mV/dec, with a rapid response time of 6 s (vs. Orion™ ROSS Ultra™ reference electrode) or 42 s (vs. miniaturized solid-state reference electrode) and a linear response over the pH range of 2–10. The pH electrode demonstrated excellent analytical performance in diverse biological fluids, including urine, serum, saliva, and surgical drain fluid, closely matching the performance of a laboratory-grade combined glass pH electrode. These results underscore the potential of the proposed platform as a reliable and technologically scalable tool for real-time pH assessment in biomedical applications.

Abstract Image

用于人体体液pH分析的高度稳定的直接印刷聚氮基小型化电极
生物体液pH监测在临床诊断和治疗管理中起着至关重要的作用。本研究提出了一种新型的固体接触pH电极,该电极采用直接印刷(DP)石墨(Gr)电极在柔性衬底上制备,然后是电聚合疏水聚氮烯(pAz)转导层和离子选择膜(ISM)。pH电极与包含光聚合PVA-KCl基质的小型化固态Ag/AgCl参比电极配对。小型化的参比电极具有优异的电位稳定性(pH 2-11范围内±2.5 mV)和最小的信号漂移(10µV/h)。小型化pH电极的灵敏度为55.7 mV/dec,快速响应时间为6 s(相对于Orion™ROSS Ultra™参比电极)或42 s(相对于小型化固态参比电极),在2-10的pH范围内具有线性响应。pH电极在多种生物液体(包括尿液、血清、唾液和手术引流液)中表现出优异的分析性能,与实验室级组合玻璃pH电极的性能密切匹配。这些结果强调了该平台作为生物医学应用中实时pH值评估的可靠和技术可扩展工具的潜力。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
CiteScore
16.50
自引率
6.20%
发文量
77
审稿时长
38 days
期刊介绍: Biocybernetics and Biomedical Engineering is a quarterly journal, founded in 1981, devoted to publishing the results of original, innovative and creative research investigations in the field of Biocybernetics and biomedical engineering, which bridges mathematical, physical, chemical and engineering methods and technology to analyse physiological processes in living organisms as well as to develop methods, devices and systems used in biology and medicine, mainly in medical diagnosis, monitoring systems and therapy. The Journal''s mission is to advance scientific discovery into new or improved standards of care, and promotion a wide-ranging exchange between science and its application to humans.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信
小红书