Design and experimental verification of the quench detection system for the CFETR central solenoid model coil

IF 9.2 Q1 ENGINEERING, ELECTRICAL & ELECTRONIC
Superconductivity Pub Date : 2025-12-01 Epub Date: 2025-11-25 DOI:10.1016/j.supcon.2025.100212
Qing Yan , Yezheng Xiao , Longgui Zheng , Chao Pan , Qicai Ni , Teng Wang , Shuqing Zhang , Yu Chen , Xianzhou Zhao , Liang Guo , Wenquan Zhang , Liangbing Hu , Yanlan Hu
{"title":"Design and experimental verification of the quench detection system for the CFETR central solenoid model coil","authors":"Qing Yan ,&nbsp;Yezheng Xiao ,&nbsp;Longgui Zheng ,&nbsp;Chao Pan ,&nbsp;Qicai Ni ,&nbsp;Teng Wang ,&nbsp;Shuqing Zhang ,&nbsp;Yu Chen ,&nbsp;Xianzhou Zhao ,&nbsp;Liang Guo ,&nbsp;Wenquan Zhang ,&nbsp;Liangbing Hu ,&nbsp;Yanlan Hu","doi":"10.1016/j.supcon.2025.100212","DOIUrl":null,"url":null,"abstract":"<div><div>To ensure the safe and stable operation of superconducting magnets in fusion devices under high current and complex operating conditions, a highly reliable quench detection system was developed for the Central Solenoid Model Coil (CSMC) of the Chinese Fusion Engineering Testing Reactor (CFETR). The system adopts voltage-based detection as the primary criterion and implements a primary induced voltage compensation architecture based on Co-Wound Wire (CWW) and Co-Wound Tape (CWT) techniques. In addition, a secondary compensation algorithm is introduced to effectively suppress the risk of misjudgment caused by electromagnetic coupling. In the system design, a multi-redundant compensation scheme was proposed with full consideration of the magnet structure and cabling constraints. During the engineering commissioning phase, both room-temperature continuity tests and low-current compensation coefficient calibration were conducted. Induced voltage suppression tests under different current variation rates demonstrated that CWT provides superior compensation performance compared to CWW, with induced voltage suppression rates exceeding 99.8 % for CWW and 99.95 % for CWT. Furthermore, reliability tests under three simulated fault scenarios confirmed that the diagnostic system could accurately identify system states without false triggers, showing strong anti-interference capability and engineering stability. Ultimately, the system was successfully deployed in a high-current energization test of the CSMC, operating at up to 48 kA. It maintained stable performance throughout the test without any false alarms or missed detections, verifying its feasibility and reliability under real engineering conditions. The quench detection compensation methods and system architecture proposed in this study provide a solid technical foundation and practical support for the future development and deployment of the CFETR Central Solenoid superconducting magnet quench detection system.</div></div>","PeriodicalId":101185,"journal":{"name":"Superconductivity","volume":"16 ","pages":"Article 100212"},"PeriodicalIF":9.2000,"publicationDate":"2025-12-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Superconductivity","FirstCategoryId":"1085","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S2772830725000638","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2025/11/25 0:00:00","PubModel":"Epub","JCR":"Q1","JCRName":"ENGINEERING, ELECTRICAL & ELECTRONIC","Score":null,"Total":0}
引用次数: 0

Abstract

To ensure the safe and stable operation of superconducting magnets in fusion devices under high current and complex operating conditions, a highly reliable quench detection system was developed for the Central Solenoid Model Coil (CSMC) of the Chinese Fusion Engineering Testing Reactor (CFETR). The system adopts voltage-based detection as the primary criterion and implements a primary induced voltage compensation architecture based on Co-Wound Wire (CWW) and Co-Wound Tape (CWT) techniques. In addition, a secondary compensation algorithm is introduced to effectively suppress the risk of misjudgment caused by electromagnetic coupling. In the system design, a multi-redundant compensation scheme was proposed with full consideration of the magnet structure and cabling constraints. During the engineering commissioning phase, both room-temperature continuity tests and low-current compensation coefficient calibration were conducted. Induced voltage suppression tests under different current variation rates demonstrated that CWT provides superior compensation performance compared to CWW, with induced voltage suppression rates exceeding 99.8 % for CWW and 99.95 % for CWT. Furthermore, reliability tests under three simulated fault scenarios confirmed that the diagnostic system could accurately identify system states without false triggers, showing strong anti-interference capability and engineering stability. Ultimately, the system was successfully deployed in a high-current energization test of the CSMC, operating at up to 48 kA. It maintained stable performance throughout the test without any false alarms or missed detections, verifying its feasibility and reliability under real engineering conditions. The quench detection compensation methods and system architecture proposed in this study provide a solid technical foundation and practical support for the future development and deployment of the CFETR Central Solenoid superconducting magnet quench detection system.
CFETR中央电磁模型线圈猝灭检测系统的设计与实验验证
为了保证核聚变装置中超导磁体在大电流和复杂工况下的安全稳定运行,针对中国核聚变工程试验堆(CFETR)的中央电磁模型线圈(CSMC)研制了一套高可靠性的猝灭检测系统。该系统采用基于电压的检测作为主要判据,实现了基于共绕线(CWW)和共绕带(CWT)技术的初级感应电压补偿体系结构。此外,引入二次补偿算法,有效地抑制了电磁耦合引起的误判风险。在系统设计中,提出了一种充分考虑磁体结构和布线约束的多冗余补偿方案。在工程调试阶段,进行了室温连续性试验和小电流补偿系数标定。不同电流变化率下的感应电压抑制试验表明,CWT比CWW具有更好的补偿性能,CWW的感应电压抑制率超过99.8%,CWT的感应电压抑制率超过99.95%。三种模拟故障场景下的可靠性试验表明,诊断系统能够准确识别系统状态,无误触发,具有较强的抗干扰能力和工程稳定性。最终,该系统成功部署在CSMC的大电流通电测试中,工作电压高达48 kA。在整个测试过程中始终保持稳定的性能,没有出现任何误报和漏检,验证了其在实际工程条件下的可行性和可靠性。本文提出的失冷检测补偿方法和系统架构为CFETR中央螺线管超导磁体失冷检测系统的未来开发部署提供了坚实的技术基础和实践支持。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
CiteScore
3.90
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信
小红书