{"title":"On the correction of lateral response artifact in accelerated radiochromic film dosimetry protocols","authors":"S. Panzuela , A.M. Bruque , J. Macías","doi":"10.1016/j.radmeas.2025.107571","DOIUrl":null,"url":null,"abstract":"<div><div>This study investigates the correction of the lateral response artifact (LRA) in accelerated protocols for radiochromic film dosimetry that shorten the time between irradiation and read-out. In these protocols, the LRA is assessed by pixel profiles along the longest axis of radiochromic film strips that are scanned parallel to the axis of artifact. The interplay between the non-uniform response of flatbed scanners and unavoidable heterogeneities in the radiation fields of linear accelerators modifies these pixel profiles, deviating them from their real behavior. This phenomenon has a negative impact on radiochromic film dosimetry. To solve this issue, first-order variations in the homogeneity of the radiation fields were subtracted from the pixel profiles. We studied dose distributions of 30 × 30 cm<sup>2</sup> square fields at different dose levels and realistic radiotherapy treatment plans, using 6 MV and 6 MV flattening filter free energies. The radiochromic film models utilized were EBT4 and EBT-XD. For evaluation, gamma analysis (2 %,2 mm) and relative root mean square error metrics were employed. Comparisons against reference measurements demonstrate this novel correction is highly effective in suppressing radiation field heterogeneities, leading to enhanced dosimetric accuracy. Moreover, this study presents a semi-analytical expression for the LRA correction, which contributes to reducing uncertainties.</div></div>","PeriodicalId":21055,"journal":{"name":"Radiation Measurements","volume":"191 ","pages":"Article 107571"},"PeriodicalIF":1.8000,"publicationDate":"2026-02-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Radiation Measurements","FirstCategoryId":"101","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S1350448725002008","RegionNum":3,"RegionCategory":"物理与天体物理","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2025/11/26 0:00:00","PubModel":"Epub","JCR":"Q2","JCRName":"NUCLEAR SCIENCE & TECHNOLOGY","Score":null,"Total":0}
引用次数: 0
Abstract
This study investigates the correction of the lateral response artifact (LRA) in accelerated protocols for radiochromic film dosimetry that shorten the time between irradiation and read-out. In these protocols, the LRA is assessed by pixel profiles along the longest axis of radiochromic film strips that are scanned parallel to the axis of artifact. The interplay between the non-uniform response of flatbed scanners and unavoidable heterogeneities in the radiation fields of linear accelerators modifies these pixel profiles, deviating them from their real behavior. This phenomenon has a negative impact on radiochromic film dosimetry. To solve this issue, first-order variations in the homogeneity of the radiation fields were subtracted from the pixel profiles. We studied dose distributions of 30 × 30 cm2 square fields at different dose levels and realistic radiotherapy treatment plans, using 6 MV and 6 MV flattening filter free energies. The radiochromic film models utilized were EBT4 and EBT-XD. For evaluation, gamma analysis (2 %,2 mm) and relative root mean square error metrics were employed. Comparisons against reference measurements demonstrate this novel correction is highly effective in suppressing radiation field heterogeneities, leading to enhanced dosimetric accuracy. Moreover, this study presents a semi-analytical expression for the LRA correction, which contributes to reducing uncertainties.
期刊介绍:
The journal seeks to publish papers that present advances in the following areas: spontaneous and stimulated luminescence (including scintillating materials, thermoluminescence, and optically stimulated luminescence); electron spin resonance of natural and synthetic materials; the physics, design and performance of radiation measurements (including computational modelling such as electronic transport simulations); the novel basic aspects of radiation measurement in medical physics. Studies of energy-transfer phenomena, track physics and microdosimetry are also of interest to the journal.
Applications relevant to the journal, particularly where they present novel detection techniques, novel analytical approaches or novel materials, include: personal dosimetry (including dosimetric quantities, active/electronic and passive monitoring techniques for photon, neutron and charged-particle exposures); environmental dosimetry (including methodological advances and predictive models related to radon, but generally excluding local survey results of radon where the main aim is to establish the radiation risk to populations); cosmic and high-energy radiation measurements (including dosimetry, space radiation effects, and single event upsets); dosimetry-based archaeological and Quaternary dating; dosimetry-based approaches to thermochronometry; accident and retrospective dosimetry (including activation detectors), and dosimetry and measurements related to medical applications.