Optimizing IABP-patient interaction in VA-ECMO via transcranial doppler.

IF 3.6 Q2 Medicine
Andres Felipe Yepes-Velasco, Jeimy Lorena Moreno-Araque, Natalia Garzon-Posada
{"title":"Optimizing IABP-patient interaction in VA-ECMO via transcranial doppler.","authors":"Andres Felipe Yepes-Velasco, Jeimy Lorena Moreno-Araque, Natalia Garzon-Posada","doi":"10.1186/s13089-025-00460-2","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>Patients supported with veno-arterial extracorporeal membrane oxygenation may receive an intra-aortic balloon pump to reduce left ventricular afterload and improve aortic diastolic pressure. However, the effect of this combined mechanical support on cerebral hemodynamics is not uniform and can be influenced by intra-aortic balloon pump timing. Bedside transcranial Doppler offers a rapid, noninvasive way to detect maladaptive cerebral flow patterns and to guide patient-device interaction in real time.</p><p><strong>Case presentation: </strong>We describe a postcardiotomy adult patient on peripheral veno-arterial extracorporeal membrane oxygenation with concomitant intra-aortic balloon pump assistance (1:1) who developed a reduction in cerebral oximetry. Transcranial Doppler of the middle cerebral artery showed increased pulsatility and reduced diastolic velocity, findings consistent with a transient decrease in cerebral perfusion pressure and compatible with balloon deflation asynchrony. Temporary suspension of balloon assistance improved the waveform. Deflation was then synchronized with the electrocardiogram so that it was completed at the onset of systole. Repeat transcranial Doppler performed minutes later showed restoration of diastolic flow and a lower pulsatility index, while extracorporeal support was maintained unchanged and the patient remained hemodynamically stable.</p><p><strong>Conclusions: </strong>In patients receiving veno-arterial extracorporeal membrane oxygenation and intra-aortic balloon pump support, cerebral blood flow may deteriorate if balloon timing is not aligned with the native cardiac cycle. Transcranial Doppler can detect these timing-related neurohemodynamic alterations at the bedside and can confirm their reversibility after simple, ECG-guided optimization of deflation. Integrating transcranial Doppler into multiparametric monitoring may help personalize mechanical circulatory support and protect cerebral perfusion in this high-risk population.</p>","PeriodicalId":36911,"journal":{"name":"Ultrasound Journal","volume":"17 1","pages":"65"},"PeriodicalIF":3.6000,"publicationDate":"2025-12-05","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC12680806/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Ultrasound Journal","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1186/s13089-025-00460-2","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"Medicine","Score":null,"Total":0}
引用次数: 0

Abstract

Background: Patients supported with veno-arterial extracorporeal membrane oxygenation may receive an intra-aortic balloon pump to reduce left ventricular afterload and improve aortic diastolic pressure. However, the effect of this combined mechanical support on cerebral hemodynamics is not uniform and can be influenced by intra-aortic balloon pump timing. Bedside transcranial Doppler offers a rapid, noninvasive way to detect maladaptive cerebral flow patterns and to guide patient-device interaction in real time.

Case presentation: We describe a postcardiotomy adult patient on peripheral veno-arterial extracorporeal membrane oxygenation with concomitant intra-aortic balloon pump assistance (1:1) who developed a reduction in cerebral oximetry. Transcranial Doppler of the middle cerebral artery showed increased pulsatility and reduced diastolic velocity, findings consistent with a transient decrease in cerebral perfusion pressure and compatible with balloon deflation asynchrony. Temporary suspension of balloon assistance improved the waveform. Deflation was then synchronized with the electrocardiogram so that it was completed at the onset of systole. Repeat transcranial Doppler performed minutes later showed restoration of diastolic flow and a lower pulsatility index, while extracorporeal support was maintained unchanged and the patient remained hemodynamically stable.

Conclusions: In patients receiving veno-arterial extracorporeal membrane oxygenation and intra-aortic balloon pump support, cerebral blood flow may deteriorate if balloon timing is not aligned with the native cardiac cycle. Transcranial Doppler can detect these timing-related neurohemodynamic alterations at the bedside and can confirm their reversibility after simple, ECG-guided optimization of deflation. Integrating transcranial Doppler into multiparametric monitoring may help personalize mechanical circulatory support and protect cerebral perfusion in this high-risk population.

Abstract Image

Abstract Image

经颅多普勒优化VA-ECMO中iabp -患者相互作用。
背景:接受静脉-动脉体外膜氧合的患者可以接受主动脉内球囊泵以减少左心室后负荷并改善主动脉舒张压。然而,这种联合机械支持对脑血流动力学的影响并不均匀,并可能受到主动脉内球囊泵时间的影响。床边经颅多普勒提供了一种快速、无创的方法来检测不适应的脑流模式,并实时指导患者与设备的交互。病例介绍:我们描述了一名心脏切开术后接受外周静脉-动脉体外膜氧合并伴有主动脉内球囊泵辅助(1:1)的成年患者,他的脑氧饱和度降低。经颅多普勒显示大脑中动脉搏动性增加,舒张速度降低,与脑灌注压的短暂性降低一致,与球囊不同步收缩相容。暂时停止气球辅助改善了波形。然后将收缩与心电图同步,以便在收缩开始时完成收缩。几分钟后复查经颅多普勒显示舒张血流恢复,脉搏指数降低,体外支持维持不变,患者血流动力学稳定。结论:在接受静脉-动脉体外膜氧合和主动脉内球囊泵支持的患者中,如果球囊时间与原心周期不一致,脑血流可能会恶化。经颅多普勒可以在床边检测到这些与时间相关的神经血流动力学改变,并在简单的心电图引导下优化通缩后确认其可逆性。将经颅多普勒纳入多参数监测可能有助于个性化机械循环支持和保护这一高危人群的脑灌注。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
Ultrasound Journal
Ultrasound Journal Health Professions-Radiological and Ultrasound Technology
CiteScore
6.80
自引率
2.90%
发文量
45
审稿时长
22 weeks
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信
小红书