Manman Du , Junting Zhou , Zhiwei Zhang , Tianteng Hao , Junfeng Han , Jin Wei , Xinwu Xie , Can Wang
{"title":"Rapid diagnosis of tuberculosis using a three-dimensional nanofiber paper-based electrochemical sensor","authors":"Manman Du , Junting Zhou , Zhiwei Zhang , Tianteng Hao , Junfeng Han , Jin Wei , Xinwu Xie , Can Wang","doi":"10.1016/j.diagmicrobio.2025.117210","DOIUrl":null,"url":null,"abstract":"<div><div>Tuberculosis (TB) is the leading cause of death caused by a single infectious pathogen. Currently, a variety of conventional methods are widely used for detecting <em>Mycobacterium tuberculosis</em> (<em>Mtb</em>) or diagnosing TB, which have made significant contributions to controlling the TB epidemic. However, these existing TB diagnostic methods still face some difficulties and cannot provide rapid, low-cost, high-sensitivity, and high-accuracy diagnostic results simultaneously. Therefore, it is imperative to develop new TB diagnostic methods that are rapid, cost-effective, and sensitive through rigorous evaluation of potential biomarkers and new detection methods. In this study, a three-dimensional nanofiber (3D NFs) paper-based electrochemical sensor was prepared using electrospinning technology, and <em>Mtb</em> secretory protein Ag85B was utilized as a biomarker to achieve point-of-care detection of TB clinical samples. The 3D NFs paper-based electrochemical sensor can achieve a wide range of <em>Bacillus Calmette–Guérin</em> detection of 10<sup>1</sup>-10<sup>8</sup> CFU/mL with good specificity. When the clinical bronchoalveolar lavage fluid samples were diluted 10<sup>3</sup> or 10<sup>4</sup> times, the 3D NFs paper-based electrochemical sensor could detect TB clinical samples with a sensitivity of up to 92.9 % and a specificity of 60 % within 5 min. 3D NFs paper-based electrochemical sensor has the advantages of low cost, high sensitivity, and fast response speed, and can realize rapid preliminary screening of TB patients.</div></div>","PeriodicalId":11329,"journal":{"name":"Diagnostic microbiology and infectious disease","volume":"114 3","pages":"Article 117210"},"PeriodicalIF":1.8000,"publicationDate":"2026-03-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Diagnostic microbiology and infectious disease","FirstCategoryId":"3","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S0732889325005322","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2025/11/28 0:00:00","PubModel":"Epub","JCR":"Q3","JCRName":"INFECTIOUS DISEASES","Score":null,"Total":0}
引用次数: 0
Abstract
Tuberculosis (TB) is the leading cause of death caused by a single infectious pathogen. Currently, a variety of conventional methods are widely used for detecting Mycobacterium tuberculosis (Mtb) or diagnosing TB, which have made significant contributions to controlling the TB epidemic. However, these existing TB diagnostic methods still face some difficulties and cannot provide rapid, low-cost, high-sensitivity, and high-accuracy diagnostic results simultaneously. Therefore, it is imperative to develop new TB diagnostic methods that are rapid, cost-effective, and sensitive through rigorous evaluation of potential biomarkers and new detection methods. In this study, a three-dimensional nanofiber (3D NFs) paper-based electrochemical sensor was prepared using electrospinning technology, and Mtb secretory protein Ag85B was utilized as a biomarker to achieve point-of-care detection of TB clinical samples. The 3D NFs paper-based electrochemical sensor can achieve a wide range of Bacillus Calmette–Guérin detection of 101-108 CFU/mL with good specificity. When the clinical bronchoalveolar lavage fluid samples were diluted 103 or 104 times, the 3D NFs paper-based electrochemical sensor could detect TB clinical samples with a sensitivity of up to 92.9 % and a specificity of 60 % within 5 min. 3D NFs paper-based electrochemical sensor has the advantages of low cost, high sensitivity, and fast response speed, and can realize rapid preliminary screening of TB patients.
期刊介绍:
Diagnostic Microbiology and Infectious Disease keeps you informed of the latest developments in clinical microbiology and the diagnosis and treatment of infectious diseases. Packed with rigorously peer-reviewed articles and studies in bacteriology, immunology, immunoserology, infectious diseases, mycology, parasitology, and virology, the journal examines new procedures, unusual cases, controversial issues, and important new literature. Diagnostic Microbiology and Infectious Disease distinguished independent editorial board, consisting of experts from many medical specialties, ensures you extensive and authoritative coverage.