Rapid diagnosis of tuberculosis using a three-dimensional nanofiber paper-based electrochemical sensor

IF 1.8 4区 医学 Q3 INFECTIOUS DISEASES
Manman Du , Junting Zhou , Zhiwei Zhang , Tianteng Hao , Junfeng Han , Jin Wei , Xinwu Xie , Can Wang
{"title":"Rapid diagnosis of tuberculosis using a three-dimensional nanofiber paper-based electrochemical sensor","authors":"Manman Du ,&nbsp;Junting Zhou ,&nbsp;Zhiwei Zhang ,&nbsp;Tianteng Hao ,&nbsp;Junfeng Han ,&nbsp;Jin Wei ,&nbsp;Xinwu Xie ,&nbsp;Can Wang","doi":"10.1016/j.diagmicrobio.2025.117210","DOIUrl":null,"url":null,"abstract":"<div><div>Tuberculosis (TB) is the leading cause of death caused by a single infectious pathogen. Currently, a variety of conventional methods are widely used for detecting <em>Mycobacterium tuberculosis</em> (<em>Mtb</em>) or diagnosing TB, which have made significant contributions to controlling the TB epidemic. However, these existing TB diagnostic methods still face some difficulties and cannot provide rapid, low-cost, high-sensitivity, and high-accuracy diagnostic results simultaneously. Therefore, it is imperative to develop new TB diagnostic methods that are rapid, cost-effective, and sensitive through rigorous evaluation of potential biomarkers and new detection methods. In this study, a three-dimensional nanofiber (3D NFs) paper-based electrochemical sensor was prepared using electrospinning technology, and <em>Mtb</em> secretory protein Ag85B was utilized as a biomarker to achieve point-of-care detection of TB clinical samples. The 3D NFs paper-based electrochemical sensor can achieve a wide range of <em>Bacillus Calmette–Guérin</em> detection of 10<sup>1</sup>-10<sup>8</sup> CFU/mL with good specificity. When the clinical bronchoalveolar lavage fluid samples were diluted 10<sup>3</sup> or 10<sup>4</sup> times, the 3D NFs paper-based electrochemical sensor could detect TB clinical samples with a sensitivity of up to 92.9 % and a specificity of 60 % within 5 min. 3D NFs paper-based electrochemical sensor has the advantages of low cost, high sensitivity, and fast response speed, and can realize rapid preliminary screening of TB patients.</div></div>","PeriodicalId":11329,"journal":{"name":"Diagnostic microbiology and infectious disease","volume":"114 3","pages":"Article 117210"},"PeriodicalIF":1.8000,"publicationDate":"2026-03-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Diagnostic microbiology and infectious disease","FirstCategoryId":"3","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S0732889325005322","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2025/11/28 0:00:00","PubModel":"Epub","JCR":"Q3","JCRName":"INFECTIOUS DISEASES","Score":null,"Total":0}
引用次数: 0

Abstract

Tuberculosis (TB) is the leading cause of death caused by a single infectious pathogen. Currently, a variety of conventional methods are widely used for detecting Mycobacterium tuberculosis (Mtb) or diagnosing TB, which have made significant contributions to controlling the TB epidemic. However, these existing TB diagnostic methods still face some difficulties and cannot provide rapid, low-cost, high-sensitivity, and high-accuracy diagnostic results simultaneously. Therefore, it is imperative to develop new TB diagnostic methods that are rapid, cost-effective, and sensitive through rigorous evaluation of potential biomarkers and new detection methods. In this study, a three-dimensional nanofiber (3D NFs) paper-based electrochemical sensor was prepared using electrospinning technology, and Mtb secretory protein Ag85B was utilized as a biomarker to achieve point-of-care detection of TB clinical samples. The 3D NFs paper-based electrochemical sensor can achieve a wide range of Bacillus Calmette–Guérin detection of 101-108 CFU/mL with good specificity. When the clinical bronchoalveolar lavage fluid samples were diluted 103 or 104 times, the 3D NFs paper-based electrochemical sensor could detect TB clinical samples with a sensitivity of up to 92.9 % and a specificity of 60 % within 5 min. 3D NFs paper-based electrochemical sensor has the advantages of low cost, high sensitivity, and fast response speed, and can realize rapid preliminary screening of TB patients.
基于纳米纤维纸的三维电化学传感器快速诊断肺结核。
结核病(TB)是由单一传染性病原体引起的主要死亡原因。目前,各种常规方法被广泛用于检测结核分枝杆菌(Mtb)或诊断结核病,为控制结核病流行做出了重大贡献。然而,这些现有的结核病诊断方法仍然面临一些困难,无法同时提供快速、低成本、高灵敏度和高精度的诊断结果。因此,必须通过严格评估潜在的生物标志物和新的检测方法,开发快速、具有成本效益和敏感的新型结核病诊断方法。本研究采用静电纺丝技术制备三维纳米纤维(3D NFs)纸基电化学传感器,以结核分枝杆菌分泌蛋白Ag85B为生物标志物,实现结核临床样品的即时检测。3D NFs纸质电化学传感器可实现101 ~ 108 CFU/mL范围内卡介子芽孢杆菌的检测,特异性好。当临床支气管肺泡灌洗液样品被稀释103倍或104倍时,3D NFs纸质电化学传感器在5 min内检测TB临床样品的灵敏度高达92.9%,特异性为60%。3D NFs纸质电化学传感器具有成本低、灵敏度高、响应速度快等优点,可实现TB患者的快速初步筛选。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
CiteScore
5.30
自引率
3.40%
发文量
149
审稿时长
56 days
期刊介绍: Diagnostic Microbiology and Infectious Disease keeps you informed of the latest developments in clinical microbiology and the diagnosis and treatment of infectious diseases. Packed with rigorously peer-reviewed articles and studies in bacteriology, immunology, immunoserology, infectious diseases, mycology, parasitology, and virology, the journal examines new procedures, unusual cases, controversial issues, and important new literature. Diagnostic Microbiology and Infectious Disease distinguished independent editorial board, consisting of experts from many medical specialties, ensures you extensive and authoritative coverage.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信
小红书