Surface Compression Alters in Vivo VisR Stiffness, Viscosity, and Anisotropy Measurements in Human Breast

IF 1.8
Anna V. Phillips;Cherie M. Kuzmiak;Doreen Steed;Caterina M. Gallippi
{"title":"Surface Compression Alters in Vivo VisR Stiffness, Viscosity, and Anisotropy Measurements in Human Breast","authors":"Anna V. Phillips;Cherie M. Kuzmiak;Doreen Steed;Caterina M. Gallippi","doi":"10.1109/OJUFFC.2025.3631426","DOIUrl":null,"url":null,"abstract":"Viscoelastic response (VisR) ultrasound has been developed by our group to interrogate tissue stiffness and viscosity. VisR has several potential advantages for breast cancer diagnostic imaging such being non-invasive and low-cost. Because ultrasound can penetrate dense breasts more effectively than mammograms, it may improve the detection of malignant masses in women with dense breasts. VisR-based estimates of stiffness, viscosity, and anisotropy have been shown in our preliminary studies to discriminate malignant and benign breast lesions. However, a potential limitation of VisR could be dependence on tissue pre-loading from applied surface compression by the practitioner. We conducted an IRB-approved clinical study of 20 women with no known breast pathologies to assess the impact of compression on VisR measurements of peak displacement (PD), relative elasticity (RE), relative viscosity (RV), and degree of anisotropy (DoA). Participants were between the ages of 30-90, and 10/20 had mammographically dense breasts. We found that surface compression significantly affected measurements of PD, RE, and RV in breast tissue, in vivo. In particular, in women with dense breasts, stiffness (via PD and RE) increased significantly with applied compression. DoA of PD, RE, and RV increased, decreased, or stayed the same with compression. No significant difference was found in DoA with compression between the breast density groups. Based on these findings, we recommend that surface compression be standardized and monitored when using VisR for clinical breast imaging, especially in women with dense breasts. Further studies are needed to identify an optimal strain range for VisR measurement repeatability.","PeriodicalId":73301,"journal":{"name":"IEEE open journal of ultrasonics, ferroelectrics, and frequency control","volume":"5 ","pages":"242-253"},"PeriodicalIF":1.8000,"publicationDate":"2025-11-11","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://ieeexplore.ieee.org/stamp/stamp.jsp?tp=&arnumber=11240139","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"IEEE open journal of ultrasonics, ferroelectrics, and frequency control","FirstCategoryId":"1085","ListUrlMain":"https://ieeexplore.ieee.org/document/11240139/","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

Viscoelastic response (VisR) ultrasound has been developed by our group to interrogate tissue stiffness and viscosity. VisR has several potential advantages for breast cancer diagnostic imaging such being non-invasive and low-cost. Because ultrasound can penetrate dense breasts more effectively than mammograms, it may improve the detection of malignant masses in women with dense breasts. VisR-based estimates of stiffness, viscosity, and anisotropy have been shown in our preliminary studies to discriminate malignant and benign breast lesions. However, a potential limitation of VisR could be dependence on tissue pre-loading from applied surface compression by the practitioner. We conducted an IRB-approved clinical study of 20 women with no known breast pathologies to assess the impact of compression on VisR measurements of peak displacement (PD), relative elasticity (RE), relative viscosity (RV), and degree of anisotropy (DoA). Participants were between the ages of 30-90, and 10/20 had mammographically dense breasts. We found that surface compression significantly affected measurements of PD, RE, and RV in breast tissue, in vivo. In particular, in women with dense breasts, stiffness (via PD and RE) increased significantly with applied compression. DoA of PD, RE, and RV increased, decreased, or stayed the same with compression. No significant difference was found in DoA with compression between the breast density groups. Based on these findings, we recommend that surface compression be standardized and monitored when using VisR for clinical breast imaging, especially in women with dense breasts. Further studies are needed to identify an optimal strain range for VisR measurement repeatability.
表面压缩改变人体乳房的体内VisR刚度、粘度和各向异性测量
粘弹性响应(VisR)超声是本课题组开发的用于询问组织刚度和粘度的超声。VisR在乳腺癌诊断成像方面有几个潜在的优势,如无创和低成本。由于超声能比乳房x光检查更有效地穿透致密的乳房,它可以提高致密乳房女性恶性肿块的检出率。在我们的初步研究中,基于visr的刚度、粘度和各向异性的估计已被证明可以区分乳腺的恶性和良性病变。然而,VisR的一个潜在限制可能是依赖于医生施加的表面压缩的组织预负荷。我们进行了一项经irb批准的临床研究,对20名没有已知乳房病变的女性进行了临床研究,以评估压缩对峰值位移(PD)、相对弹性(RE)、相对粘度(RV)和各向异性程度(DoA)的VisR测量的影响。参与者的年龄在30-90岁之间,其中10/20患有乳房x光检查显示的致密乳房。我们发现,表面压缩显著影响体内乳腺组织PD、RE和RV的测量。特别是,在乳房致密的女性中,施加压迫时僵硬度(通过PD和RE)显著增加。PD、RE、RV的DoA随压缩增大、减小或保持不变。乳腺密度组间受压DoA无显著差异。基于这些发现,我们建议在使用VisR进行临床乳房成像时,特别是在乳房致密的女性中,对表面压缩进行标准化和监测。需要进一步的研究来确定VisR测量重复性的最佳应变范围。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信
小红书