Effect of moisture and pH on setting time and microhardness of three premixed calcium silicate-based root canal sealers: an in vitro experimental study.

IF 2.9
Restorative Dentistry & Endodontics Pub Date : 2025-11-01 Epub Date: 2025-11-28 DOI:10.5395/rde.2025.50.e41
Sooyoun Kim
{"title":"Effect of moisture and pH on setting time and microhardness of three premixed calcium silicate-based root canal sealers: an in vitro experimental study.","authors":"Sooyoun Kim","doi":"10.5395/rde.2025.50.e41","DOIUrl":null,"url":null,"abstract":"<p><strong>Objectives: </strong>The study aimed to investigate how environmental conditions impact the setting time and microhardness of premixed calcium silicate-based sealers.</p><p><strong>Methods: </strong>The setting time and microhardness of three sealers (Endoseal MTA [MARUCHI], One-Fil [MEDICLUS], and Well-Root ST [VERICOM]) were evaluated under four environmental conditions: unsoaked, distilled water-soaked, phosphate-buffered saline-soaked, and pH 5-soaked gypsum molds (n = 12/group/condition). The setting time was measured with Gilmore needles, and microhardness was assessed using a Vickers tester after 3 days. Welch's analysis of variance and Games-Howell post hoc tests were used for statistical analysis.</p><p><strong>Results: </strong>The sealer type and environmental conditions significantly influenced setting time and microhardness (p < 0.001). The initial and final setting times were the shortest in the unsoaked samples. For Endoseal MTA and One-Fil, the unsoaked condition exhibited significantly shorter setting times than the soaked conditions. Well-Root ST exhibited significantly longer setting times in acidic conditions. Surface microhardness was highest in the unsoaked group (p < 0.001). Among the soaked groups, the phosphate-buffered saline-soaked group had the lowest hardness for Endoseal MTA, whereas the pH 5-soaked group exhibited the lowest hardness for One-Fil and Well-Root ST. Endoseal MTA consistently demonstrated a lower microhardness than the other sealers (p < 0.001).</p><p><strong>Conclusions: </strong>Moisture, pH, and solution chemistry influenced the setting time and microhardness of premixed calcium silicate sealers. Although acidic conditions generally prolong the setting time and reduce hardness, the effects vary based on the sealers used and the setting environment.</p>","PeriodicalId":21102,"journal":{"name":"Restorative Dentistry & Endodontics","volume":"50 4","pages":"e41"},"PeriodicalIF":2.9000,"publicationDate":"2025-11-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC12707566/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Restorative Dentistry & Endodontics","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.5395/rde.2025.50.e41","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2025/11/28 0:00:00","PubModel":"Epub","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

Objectives: The study aimed to investigate how environmental conditions impact the setting time and microhardness of premixed calcium silicate-based sealers.

Methods: The setting time and microhardness of three sealers (Endoseal MTA [MARUCHI], One-Fil [MEDICLUS], and Well-Root ST [VERICOM]) were evaluated under four environmental conditions: unsoaked, distilled water-soaked, phosphate-buffered saline-soaked, and pH 5-soaked gypsum molds (n = 12/group/condition). The setting time was measured with Gilmore needles, and microhardness was assessed using a Vickers tester after 3 days. Welch's analysis of variance and Games-Howell post hoc tests were used for statistical analysis.

Results: The sealer type and environmental conditions significantly influenced setting time and microhardness (p < 0.001). The initial and final setting times were the shortest in the unsoaked samples. For Endoseal MTA and One-Fil, the unsoaked condition exhibited significantly shorter setting times than the soaked conditions. Well-Root ST exhibited significantly longer setting times in acidic conditions. Surface microhardness was highest in the unsoaked group (p < 0.001). Among the soaked groups, the phosphate-buffered saline-soaked group had the lowest hardness for Endoseal MTA, whereas the pH 5-soaked group exhibited the lowest hardness for One-Fil and Well-Root ST. Endoseal MTA consistently demonstrated a lower microhardness than the other sealers (p < 0.001).

Conclusions: Moisture, pH, and solution chemistry influenced the setting time and microhardness of premixed calcium silicate sealers. Although acidic conditions generally prolong the setting time and reduce hardness, the effects vary based on the sealers used and the setting environment.

Abstract Image

Abstract Image

Abstract Image

水分和pH值对三种预混硅酸钙根管密封剂凝固时间和显微硬度影响的体外实验研究。
目的:研究环境条件对预混硅酸钙基封口剂凝固时间和显微硬度的影响。方法:在未浸泡、蒸馏水浸泡、磷酸盐缓冲盐水浸泡和pH 5浸泡石膏模4种环境条件下(n = 12/组/条件),评价3种石膏模(Endoseal MTA [MARUCHI]、One-Fil [MEDICLUS]和Well-Root ST [VERICOM])的凝固时间和显微硬度。用Gilmore针测定凝固时间,3天后用维氏硬度计测定显微硬度。统计分析采用Welch的方差分析和game - howell事后检验。结果:封口器类型和环境条件对凝固时间和显微硬度有显著影响(p < 0.001)。未浸泡样品的初凝时间和终凝时间最短。对于Endoseal MTA和One-Fil,未浸泡条件下的凝固时间明显短于浸泡条件。井根ST在酸性条件下的坐封时间明显延长。表面显微硬度以未浸泡组最高(p < 0.001)。在浸泡组中,磷酸盐缓冲盐水浸泡组对Endoseal MTA的硬度最低,而pH 5浸泡组对One-Fil和Well-Root st的硬度最低,Endoseal MTA的显微硬度也低于其他浸泡组(p < 0.001)。结论:水分、pH、溶液化学等因素影响硅酸钙预混胶的凝固时间和显微硬度。虽然酸性条件通常会延长固化时间并降低硬度,但效果因所使用的封口剂和固化环境而异。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
CiteScore
0.20
自引率
0.00%
发文量
35
审稿时长
12 weeks
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信
小红书