Diagnostic accuracy of 18-lead versus 12-lead electrocardiography in acute coronary syndrome: A systematic review and meta-analysis

IF 1.5 4区 医学 Q3 CARDIAC & CARDIOVASCULAR SYSTEMS
Journal of electrocardiology Pub Date : 2026-01-01 Epub Date: 2025-11-26 DOI:10.1016/j.jelectrocard.2025.154161
Almaz Rehman Koolikad, Syed Ahmad Khan, Muhammad Shahzaib, Bushra Arif, Shivam Singla, Bhavna Singla, Muhammad Subhan, Abida Perveen, Jahanzeb Malik
{"title":"Diagnostic accuracy of 18-lead versus 12-lead electrocardiography in acute coronary syndrome: A systematic review and meta-analysis","authors":"Almaz Rehman Koolikad,&nbsp;Syed Ahmad Khan,&nbsp;Muhammad Shahzaib,&nbsp;Bushra Arif,&nbsp;Shivam Singla,&nbsp;Bhavna Singla,&nbsp;Muhammad Subhan,&nbsp;Abida Perveen,&nbsp;Jahanzeb Malik","doi":"10.1016/j.jelectrocard.2025.154161","DOIUrl":null,"url":null,"abstract":"<div><h3>Objective</h3><div>To evaluate the diagnostic accuracy and clinical impact of 18‑lead electrocardiography compared with conventional 12‑lead ECG in patients with suspected acute coronary syndromes (ACS).</div></div><div><h3>Methods</h3><div>A systematic review and meta-analysis were conducted by searching PubMed, Embase, Scopus, and the Cochrane Library from inception to August 2025. Eligible studies compared 18‑lead with 12‑lead ECG using angiography, biomarkers, or imaging as reference standards. Data were extracted to construct 2 × 2 tables where available, and pooled sensitivity, specificity, and risk ratios were calculated using random-effects models. Risk of bias was assessed with QUADAS-2, and certainty of evidence was graded with GRADE.</div></div><div><h3>Results</h3><div>Seven studies met the inclusion criteria, of which four provided extractable diagnostic accuracy data (n ≈ 535). Across studies, 18‑lead ECG significantly improved sensitivity for posterior myocardial infarction (≈80–85 % vs 55–65 % with 12‑lead) and right ventricular infarction (≈78 % vs 58 %) while preserving specificity (≈90 %). Pooled analysis demonstrated a 34 % relative improvement in diagnostic yield (RR 1.34, 95 % CI 1.18–1.55; <em>p</em> &lt; 0.01). Approximately 10–15 % of patients initially classified as NSTEMI were reclassified as STEMI-equivalents using 18‑lead recordings. Evidence of earlier catheterization laboratory activation was noted in emergency department cohorts.</div></div><div><h3>Conclusion</h3><div>Eighteen‑lead ECG enhances detection of posterior and right ventricular infarctions without loss of specificity and supports earlier intervention. Broader clinical adoption and outcome-focused trials are warranted.</div></div>","PeriodicalId":15606,"journal":{"name":"Journal of electrocardiology","volume":"94 ","pages":"Article 154161"},"PeriodicalIF":1.5000,"publicationDate":"2026-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of electrocardiology","FirstCategoryId":"3","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S0022073625002894","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2025/11/26 0:00:00","PubModel":"Epub","JCR":"Q3","JCRName":"CARDIAC & CARDIOVASCULAR SYSTEMS","Score":null,"Total":0}
引用次数: 0

Abstract

Objective

To evaluate the diagnostic accuracy and clinical impact of 18‑lead electrocardiography compared with conventional 12‑lead ECG in patients with suspected acute coronary syndromes (ACS).

Methods

A systematic review and meta-analysis were conducted by searching PubMed, Embase, Scopus, and the Cochrane Library from inception to August 2025. Eligible studies compared 18‑lead with 12‑lead ECG using angiography, biomarkers, or imaging as reference standards. Data were extracted to construct 2 × 2 tables where available, and pooled sensitivity, specificity, and risk ratios were calculated using random-effects models. Risk of bias was assessed with QUADAS-2, and certainty of evidence was graded with GRADE.

Results

Seven studies met the inclusion criteria, of which four provided extractable diagnostic accuracy data (n ≈ 535). Across studies, 18‑lead ECG significantly improved sensitivity for posterior myocardial infarction (≈80–85 % vs 55–65 % with 12‑lead) and right ventricular infarction (≈78 % vs 58 %) while preserving specificity (≈90 %). Pooled analysis demonstrated a 34 % relative improvement in diagnostic yield (RR 1.34, 95 % CI 1.18–1.55; p < 0.01). Approximately 10–15 % of patients initially classified as NSTEMI were reclassified as STEMI-equivalents using 18‑lead recordings. Evidence of earlier catheterization laboratory activation was noted in emergency department cohorts.

Conclusion

Eighteen‑lead ECG enhances detection of posterior and right ventricular infarctions without loss of specificity and supports earlier intervention. Broader clinical adoption and outcome-focused trials are warranted.

Abstract Image

18导联与12导联心电图对急性冠状动脉综合征的诊断准确性:系统回顾和荟萃分析。
目的:评价18导联心电图与常规12导联心电图对疑似急性冠脉综合征(ACS)的诊断准确性及临床意义。方法:通过检索PubMed、Embase、Scopus和Cochrane Library自成立至2025年8月的文献进行系统评价和meta分析。符合条件的研究比较了18导联和12导联心电图,使用血管造影、生物标志物或成像作为参考标准。在可能的情况下,提取数据构建2 × 2表,并使用随机效应模型计算合并敏感性、特异性和风险比。偏倚风险采用QUADAS-2进行评估,证据的确定性采用GRADE分级。结果:7项研究符合纳入标准,其中4项提供可提取的诊断准确性数据(n≈535)。在所有研究中,18导联心电图显著提高了对后置心肌梗死(≈80- 85% vs 55- 65%)和右心室梗死(≈78% vs 58%)的敏感性,同时保留了特异性(≈90%)。合并分析显示,诊断率相对提高34% (RR 1.34, 95% CI 1.18-1.55; p)。结论:十八导联心电图增强了对后室和右室梗死的检测,而不丧失特异性,支持早期干预。更广泛的临床应用和以结果为重点的试验是必要的。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
Journal of electrocardiology
Journal of electrocardiology 医学-心血管系统
CiteScore
2.70
自引率
7.70%
发文量
152
审稿时长
38 days
期刊介绍: The Journal of Electrocardiology is devoted exclusively to clinical and experimental studies of the electrical activities of the heart. It seeks to contribute significantly to the accuracy of diagnosis and prognosis and the effective treatment, prevention, or delay of heart disease. Editorial contents include electrocardiography, vectorcardiography, arrhythmias, membrane action potential, cardiac pacing, monitoring defibrillation, instrumentation, drug effects, and computer applications.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信
小红书