Accuracy of polyvinyl siloxane ether and other impression materials in full-arch implant rehabilitation with varying angulations: A comparative in vitro study.

IF 1.8 4区 医学 Q2 DENTISTRY, ORAL SURGERY & MEDICINE
Akanay Copuroglu, Zeynep Ozkurt-Kayahan, Ender Kazazoglu
{"title":"Accuracy of polyvinyl siloxane ether and other impression materials in full-arch implant rehabilitation with varying angulations: A comparative in vitro study.","authors":"Akanay Copuroglu, Zeynep Ozkurt-Kayahan, Ender Kazazoglu","doi":"10.4012/dmj.2025-150","DOIUrl":null,"url":null,"abstract":"<p><p>This study evaluated the accuracy of digital and conventional impressions using different materials in fully edentulous jaws with implants at varying angulations. Two master models were fabricated: one with four parallel and another with four implants placed according to the all-on-4 protocol. Impressions were obtained using three materials-polyvinyl siloxane (PVS), polyether (PE), and polyvinyl siloxane ether (PVSE)-and a digital scanner (TRIOS 4). Conventional impressions were cast, scanned with an extraoral scanner, and compared with the reference models via Geomagic Control X software. In the parallel model, digital impressions exhibited significantly greater deviation values than PE (p=0.016). In the angulated model, PE demonstrated significantly lower deviation values compared to PVSE (p=0.007) and digital impressions (p=0.016). Deviation values increased with implant angulation in all groups, except PVSE, which showed no statistically significant difference. Polyether provided the highest accuracy. Implant angulation adversely affected accuracy across most impression methods.</p>","PeriodicalId":11065,"journal":{"name":"Dental materials journal","volume":" ","pages":""},"PeriodicalIF":1.8000,"publicationDate":"2025-12-04","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Dental materials journal","FirstCategoryId":"5","ListUrlMain":"https://doi.org/10.4012/dmj.2025-150","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"DENTISTRY, ORAL SURGERY & MEDICINE","Score":null,"Total":0}
引用次数: 0

Abstract

This study evaluated the accuracy of digital and conventional impressions using different materials in fully edentulous jaws with implants at varying angulations. Two master models were fabricated: one with four parallel and another with four implants placed according to the all-on-4 protocol. Impressions were obtained using three materials-polyvinyl siloxane (PVS), polyether (PE), and polyvinyl siloxane ether (PVSE)-and a digital scanner (TRIOS 4). Conventional impressions were cast, scanned with an extraoral scanner, and compared with the reference models via Geomagic Control X software. In the parallel model, digital impressions exhibited significantly greater deviation values than PE (p=0.016). In the angulated model, PE demonstrated significantly lower deviation values compared to PVSE (p=0.007) and digital impressions (p=0.016). Deviation values increased with implant angulation in all groups, except PVSE, which showed no statistically significant difference. Polyether provided the highest accuracy. Implant angulation adversely affected accuracy across most impression methods.

聚乙烯醇硅氧烷醚和其他印模材料在不同角度全弓种植体康复中的准确性:一项体外比较研究。
本研究评估了数字印模和传统印模使用不同材料在不同角度种植的全无牙颌上的准确性。制作了两个主模型:一个有四个并行模型,另一个有四个植入物,根据all-on-4协议放置。印痕是用三种材料——聚氯乙烯硅氧烷(PVS)、聚醚(PE)和聚氯乙烯硅氧烷醚(PVSE)——和数字扫描仪(TRIOS 4)获得的。常规印模铸造,用口外扫描仪扫描,并通过Geomagic Control X软件与参考模型进行比较。在平行模型中,数字印痕的偏差值明显大于PE (p=0.016)。在成角模型中,PE与PVSE (p=0.007)和数字印象(p=0.016)相比,偏差值显着降低。各组偏差值随种植体成角增加而增加,PVSE组除外,差异无统计学意义。聚醚提供了最高的精度。种植体角度对大多数印模方法的准确性有不利影响。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
Dental materials journal
Dental materials journal 医学-材料科学:生物材料
CiteScore
4.60
自引率
4.00%
发文量
102
审稿时长
3 months
期刊介绍: Dental Materials Journal is a peer review journal published by the Japanese Society for Dental Materials and Devises aiming to introduce the progress of the basic and applied sciences in dental materials and biomaterials. The dental materials-related clinical science and instrumental technologies are also within the scope of this journal. The materials dealt include synthetic polymers, ceramics, metals and tissue-derived biomaterials. Forefront dental materials and biomaterials used in developing filed, such as tissue engineering, bioengineering and artificial intelligence, are positively considered for the review as well. Recent acceptance rate of the submitted manuscript in the journal is around 30%.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信
小红书