Accuracy of polyvinyl siloxane ether and other impression materials in full-arch implant rehabilitation with varying angulations: A comparative in vitro study.
{"title":"Accuracy of polyvinyl siloxane ether and other impression materials in full-arch implant rehabilitation with varying angulations: A comparative in vitro study.","authors":"Akanay Copuroglu, Zeynep Ozkurt-Kayahan, Ender Kazazoglu","doi":"10.4012/dmj.2025-150","DOIUrl":null,"url":null,"abstract":"<p><p>This study evaluated the accuracy of digital and conventional impressions using different materials in fully edentulous jaws with implants at varying angulations. Two master models were fabricated: one with four parallel and another with four implants placed according to the all-on-4 protocol. Impressions were obtained using three materials-polyvinyl siloxane (PVS), polyether (PE), and polyvinyl siloxane ether (PVSE)-and a digital scanner (TRIOS 4). Conventional impressions were cast, scanned with an extraoral scanner, and compared with the reference models via Geomagic Control X software. In the parallel model, digital impressions exhibited significantly greater deviation values than PE (p=0.016). In the angulated model, PE demonstrated significantly lower deviation values compared to PVSE (p=0.007) and digital impressions (p=0.016). Deviation values increased with implant angulation in all groups, except PVSE, which showed no statistically significant difference. Polyether provided the highest accuracy. Implant angulation adversely affected accuracy across most impression methods.</p>","PeriodicalId":11065,"journal":{"name":"Dental materials journal","volume":" ","pages":""},"PeriodicalIF":1.8000,"publicationDate":"2025-12-04","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Dental materials journal","FirstCategoryId":"5","ListUrlMain":"https://doi.org/10.4012/dmj.2025-150","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"DENTISTRY, ORAL SURGERY & MEDICINE","Score":null,"Total":0}
引用次数: 0
Abstract
This study evaluated the accuracy of digital and conventional impressions using different materials in fully edentulous jaws with implants at varying angulations. Two master models were fabricated: one with four parallel and another with four implants placed according to the all-on-4 protocol. Impressions were obtained using three materials-polyvinyl siloxane (PVS), polyether (PE), and polyvinyl siloxane ether (PVSE)-and a digital scanner (TRIOS 4). Conventional impressions were cast, scanned with an extraoral scanner, and compared with the reference models via Geomagic Control X software. In the parallel model, digital impressions exhibited significantly greater deviation values than PE (p=0.016). In the angulated model, PE demonstrated significantly lower deviation values compared to PVSE (p=0.007) and digital impressions (p=0.016). Deviation values increased with implant angulation in all groups, except PVSE, which showed no statistically significant difference. Polyether provided the highest accuracy. Implant angulation adversely affected accuracy across most impression methods.
期刊介绍:
Dental Materials Journal is a peer review journal published by the Japanese Society for Dental Materials and Devises aiming to introduce the progress of the basic and applied sciences in dental materials and biomaterials. The dental materials-related clinical science and instrumental technologies are also within the scope of this journal. The materials dealt include synthetic polymers, ceramics, metals and tissue-derived biomaterials. Forefront dental materials and biomaterials used in developing filed, such as tissue engineering, bioengineering and artificial intelligence, are positively considered for the review as well. Recent acceptance rate of the submitted manuscript in the journal is around 30%.