Blood‒brain barrier opening with Golay-coded ultrasound to improve therapeutic consistency in glioblastoma models.

IF 8 2区 医学 Q1 PHARMACOLOGY & PHARMACY
Drug Delivery Pub Date : 2025-12-31 Epub Date: 2025-12-03 DOI:10.1080/10717544.2025.2592940
Seoyun Chang, Taekyu Jang, Hyochul Lee, Minseok Koo, Ok Kyu Park, Seung Hong Choi, Roh-Eul Yoo, Jinhyoung Park
{"title":"Blood‒brain barrier opening with Golay-coded ultrasound to improve therapeutic consistency in glioblastoma models.","authors":"Seoyun Chang, Taekyu Jang, Hyochul Lee, Minseok Koo, Ok Kyu Park, Seung Hong Choi, Roh-Eul Yoo, Jinhyoung Park","doi":"10.1080/10717544.2025.2592940","DOIUrl":null,"url":null,"abstract":"<p><p>Transcranial-focused ultrasound has demonstrated potential for blood-brain barrier (BBB) opening and localized drug delivery to intracranial brain lesions, making it a promising therapeutic strategy for glioblastoma (GBM) treatment. However, consistent drug delivery is hindered by cranial beam distortions, particularly standing-wave formation, when conventional sinusoidal-periodic ultrasound transmission sequences are used. We propose a novel Golay-coded random (Golay-random) ultrasound transmission sequence to mitigate standing wave effects and address this challenge. The efficacy of the Golay-random sequence was validated through computational simulations, which revealed significantly reduced pressure fluctuations compared to that in sinusoidal-periodic sequences. In vivo experiments quantified the BBB opening using gadolinium contrast-enhanced magnetic resonance imaging (MRI). The Golay-random sequence demonstrated effective BBB opening, with BBB permeability-increasing with burst length from 1.25 to 2.50 ms and plateauing at 5.00 ms. In contrast, no consistent correlation between burst length and BBB opening was observed with the sinusoidal-periodic sequence. In GBM mouse models, posttreatment MRI revealed significantly smaller tumor sizes in the group receiving doxorubicin with Golay-random transmission (G-Dox: 3.72 ± 4.34 mm³) compared to those with sinusoidal-periodic transmission (P-Dox: 18.05 ± 11.81 mm³). Optical in vivo imaging corroborated these findings, showing reduced tumor progression in the G-Dox group (4.54 ± 5.67) relative to the P-Dox group (25.17 ± 33.71). These results highlight the Golay-random sequence as a superior alternative to conventional sinusoidal-periodic sequences, offering improved precision and reliability in drug delivery and enhanced therapies for GBM.</p>","PeriodicalId":11679,"journal":{"name":"Drug Delivery","volume":"32 1","pages":"2592940"},"PeriodicalIF":8.0000,"publicationDate":"2025-12-31","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC12679851/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Drug Delivery","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1080/10717544.2025.2592940","RegionNum":2,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2025/12/3 0:00:00","PubModel":"Epub","JCR":"Q1","JCRName":"PHARMACOLOGY & PHARMACY","Score":null,"Total":0}
引用次数: 0

Abstract

Transcranial-focused ultrasound has demonstrated potential for blood-brain barrier (BBB) opening and localized drug delivery to intracranial brain lesions, making it a promising therapeutic strategy for glioblastoma (GBM) treatment. However, consistent drug delivery is hindered by cranial beam distortions, particularly standing-wave formation, when conventional sinusoidal-periodic ultrasound transmission sequences are used. We propose a novel Golay-coded random (Golay-random) ultrasound transmission sequence to mitigate standing wave effects and address this challenge. The efficacy of the Golay-random sequence was validated through computational simulations, which revealed significantly reduced pressure fluctuations compared to that in sinusoidal-periodic sequences. In vivo experiments quantified the BBB opening using gadolinium contrast-enhanced magnetic resonance imaging (MRI). The Golay-random sequence demonstrated effective BBB opening, with BBB permeability-increasing with burst length from 1.25 to 2.50 ms and plateauing at 5.00 ms. In contrast, no consistent correlation between burst length and BBB opening was observed with the sinusoidal-periodic sequence. In GBM mouse models, posttreatment MRI revealed significantly smaller tumor sizes in the group receiving doxorubicin with Golay-random transmission (G-Dox: 3.72 ± 4.34 mm³) compared to those with sinusoidal-periodic transmission (P-Dox: 18.05 ± 11.81 mm³). Optical in vivo imaging corroborated these findings, showing reduced tumor progression in the G-Dox group (4.54 ± 5.67) relative to the P-Dox group (25.17 ± 33.71). These results highlight the Golay-random sequence as a superior alternative to conventional sinusoidal-periodic sequences, offering improved precision and reliability in drug delivery and enhanced therapies for GBM.

用golay编码超声打开血脑屏障以提高胶质母细胞瘤模型的治疗一致性。
经颅聚焦超声已被证明具有打开血脑屏障(BBB)和向颅内病变局部递送药物的潜力,使其成为治疗胶质母细胞瘤(GBM)的一种有前景的治疗策略。然而,当使用传统的正弦周期超声传输序列时,持续的药物递送会受到颅束畸变的阻碍,特别是驻波形成。我们提出了一种新的golay编码随机(Golay-random)超声传输序列来减轻驻波效应并解决这一挑战。通过计算模拟验证了Golay-random序列的有效性,结果表明与正弦周期序列相比,压力波动显著降低。体内实验使用钆对比增强磁共振成像(MRI)定量血脑屏障开口。Golay-random序列显示出有效的血脑屏障开放,血脑屏障渗透率随着爆发长度从1.25 ms增加到2.50 ms,并在5.00 ms时达到稳定。相反,脉冲长度和血脑屏障开放与正弦波周期序列之间没有一致的相关性。在GBM小鼠模型中,治疗后MRI显示,阿霉素随机传递组(G-Dox: 3.72±4.34 mm³)的肿瘤体积明显小于正弦周期传递组(P-Dox: 18.05±11.81 mm³)。体内光学成像证实了这些发现,显示G-Dox组(4.54±5.67)相对于P-Dox组(25.17±33.71)肿瘤进展减少。这些结果突出了Golay-random序列作为传统正弦周期序列的优越替代品,在给药和增强治疗GBM方面提供了更高的精度和可靠性。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
Drug Delivery
Drug Delivery 医学-药学
CiteScore
11.80
自引率
5.00%
发文量
250
审稿时长
3.3 months
期刊介绍: Drug Delivery is an open access journal serving the academic and industrial communities with peer reviewed coverage of basic research, development, and application principles of drug delivery and targeting at molecular, cellular, and higher levels. Topics covered include all delivery systems including oral, pulmonary, nasal, parenteral and transdermal, and modes of entry such as controlled release systems; microcapsules, liposomes, vesicles, and macromolecular conjugates; antibody targeting; protein/peptide delivery; DNA, oligonucleotide and siRNA delivery. Papers on drug dosage forms and their optimization will not be considered unless they directly relate to the original drug delivery issues. Published articles present original research and critical reviews.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信
小红书