{"title":"[Comparative study on the accuracy of extraoral scanning versus intraoral scanning in digital impressions for implant restoration in edentulous jaws].","authors":"Yongtao Yang, Xin Li, Xiangyi Shang, Shenyao Shan, Wenbo Li, Qingzhao Qin, Yong Wang, Yijiao Zhao","doi":"10.7518/hxkq.2025.2025077","DOIUrl":null,"url":null,"abstract":"<p><strong>Objectives: </strong>To evaluate the accuracy of a self-developed extraoral scanning system based on four-camera stereophotogrammetric technology in the acquisition of three-dimensional positional information on dental implants and conduct a comparative study involving an intraoral scanning system.</p><p><strong>Methods: </strong>With the use of an <i>in vitro</i> edentulous jaw model with implants, extraoral (experimental group) and intraoral (control group) scanning systems were employed to obtain STL (Standard Tessellation Language) datasets containing three-dimensional morphological and positional information on scan bodies. In addition, a dental model scanner was used to obtain reference data. The three-dimensional morphological, linear, and angular deviations between groups and reference data were analyzed using Geomagic Wrap 2021 software to compare trueness and precision.</p><p><strong>Results: </strong>The extraoral scanning system demonstrated superior trueness in three-dimensional morphological, linear, and angular deviations compared with the intraoral scanning system, with statistically significant differences (<i>P</i><0.001). The extraoral scanning system also showed a higher precision in three-dimensional morphological deviation (<i>P</i><0.001). As the number of implants increased, the extraoral scanning system exhibited increased three-dimensional morphological and linear deviations (<i>P</i><0.001) but maintained a stable angular deviation. The intraoral scanning system displayed significant increases in three-dimensional morphological, linear, and angular deviations with the increase in the number of implants (<i>P</i><0.05).</p><p><strong>Conclusions: </strong>The stereophotogrammetry-based extraoral scanning system outperforms intraoral scanning system in terms of the accuracy for multi-unit implant positioning and provides a novel approach for attaining a fully digital workflow for implant rehabilitation in edentulous jaws.</p>","PeriodicalId":94028,"journal":{"name":"Hua xi kou qiang yi xue za zhi = Huaxi kouqiang yixue zazhi = West China journal of stomatology","volume":"43 6","pages":"771-779"},"PeriodicalIF":0.0000,"publicationDate":"2025-12-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC12680125/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Hua xi kou qiang yi xue za zhi = Huaxi kouqiang yixue zazhi = West China journal of stomatology","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.7518/hxkq.2025.2025077","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

Objectives: To evaluate the accuracy of a self-developed extraoral scanning system based on four-camera stereophotogrammetric technology in the acquisition of three-dimensional positional information on dental implants and conduct a comparative study involving an intraoral scanning system.

Methods: With the use of an in vitro edentulous jaw model with implants, extraoral (experimental group) and intraoral (control group) scanning systems were employed to obtain STL (Standard Tessellation Language) datasets containing three-dimensional morphological and positional information on scan bodies. In addition, a dental model scanner was used to obtain reference data. The three-dimensional morphological, linear, and angular deviations between groups and reference data were analyzed using Geomagic Wrap 2021 software to compare trueness and precision.

Results: The extraoral scanning system demonstrated superior trueness in three-dimensional morphological, linear, and angular deviations compared with the intraoral scanning system, with statistically significant differences (P<0.001). The extraoral scanning system also showed a higher precision in three-dimensional morphological deviation (P<0.001). As the number of implants increased, the extraoral scanning system exhibited increased three-dimensional morphological and linear deviations (P<0.001) but maintained a stable angular deviation. The intraoral scanning system displayed significant increases in three-dimensional morphological, linear, and angular deviations with the increase in the number of implants (P<0.05).

Conclusions: The stereophotogrammetry-based extraoral scanning system outperforms intraoral scanning system in terms of the accuracy for multi-unit implant positioning and provides a novel approach for attaining a fully digital workflow for implant rehabilitation in edentulous jaws.

[无牙颌种植体修复数字印模中口外扫描与口内扫描准确性的比较研究]。
目的:评价自行研制的基于四摄像头立体摄影测量技术的口腔外扫描系统获取种植体三维位置信息的准确性,并与口腔内扫描系统进行对比研究。方法:采用带种植体的体外无牙颌模型,采用口外(实验组)和口内(对照组)扫描系统获取包含扫描体三维形态和位置信息的STL (Standard Tessellation Language)数据集。此外,使用牙模型扫描仪获取参考数据。利用Geomagic Wrap 2021软件分析各组与参考数据之间的三维形态、线性和角度偏差,比较真实感和精度。结果:与口腔内扫描系统相比,口腔外扫描系统在三维形态、线性和角度偏差方面表现出更好的准确性,差异有统计学意义(ppppp)。基于立体摄影测量的口腔外扫描系统在多单元种植体定位的准确性方面优于口腔内扫描系统,并为实现无牙颌种植体康复的全数字化工作流程提供了一种新方法。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信
小红书