{"title":"Technical Parameters and Feedback Control for Blood-Brain Barrier Permeability Enhancement by Focused Ultrasound","authors":"Yuexi Huang;Kullervo Hynynen","doi":"10.1109/RBME.2025.3636806","DOIUrl":null,"url":null,"abstract":"Focused ultrasound combined with intravenously infused microbubbles has been shown to effectively enhance the permeability of the blood-brain barrier, facilitating drug delivery to the brain. A wide range of technical parameters has been evaluated through preclinical studies and clinical trials. Generally, a low frequency between 200 and 300 kHz is preferred for the transcranial approach, while 1 MHz is used in implantable devices. Standard parameters include a burst length of 5 to 10 ms, a pulse repetition frequency of 0.2 to 10 Hz, and sonication durations of 90 to 180 seconds. A pressure magnitude around 0.46 mechanical index appears to be near the threshold for BBB permeability enhancement at standard microbubble dosage without causing hemorrhage. Various microbubble and nanobubble types have been tested at different doses, which in principle can be normalized by gas volume. Control methods that use harmonic emmisions for power feedback have been proposed to enhance consistency and account for patient variability, and these methods are currently being tested in several clinical trials.","PeriodicalId":39235,"journal":{"name":"IEEE Reviews in Biomedical Engineering","volume":"19 ","pages":"216-226"},"PeriodicalIF":16.0000,"publicationDate":"2025-12-02","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://ieeexplore.ieee.org/stamp/stamp.jsp?tp=&arnumber=11272135","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"IEEE Reviews in Biomedical Engineering","FirstCategoryId":"5","ListUrlMain":"https://ieeexplore.ieee.org/document/11272135/","RegionNum":1,"RegionCategory":"工程技术","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"ENGINEERING, BIOMEDICAL","Score":null,"Total":0}
引用次数: 0
Abstract
Focused ultrasound combined with intravenously infused microbubbles has been shown to effectively enhance the permeability of the blood-brain barrier, facilitating drug delivery to the brain. A wide range of technical parameters has been evaluated through preclinical studies and clinical trials. Generally, a low frequency between 200 and 300 kHz is preferred for the transcranial approach, while 1 MHz is used in implantable devices. Standard parameters include a burst length of 5 to 10 ms, a pulse repetition frequency of 0.2 to 10 Hz, and sonication durations of 90 to 180 seconds. A pressure magnitude around 0.46 mechanical index appears to be near the threshold for BBB permeability enhancement at standard microbubble dosage without causing hemorrhage. Various microbubble and nanobubble types have been tested at different doses, which in principle can be normalized by gas volume. Control methods that use harmonic emmisions for power feedback have been proposed to enhance consistency and account for patient variability, and these methods are currently being tested in several clinical trials.
期刊介绍:
IEEE Reviews in Biomedical Engineering (RBME) serves as a platform to review the state-of-the-art and trends in the interdisciplinary field of biomedical engineering, which encompasses engineering, life sciences, and medicine. The journal aims to consolidate research and reviews for members of all IEEE societies interested in biomedical engineering. Recognizing the demand for comprehensive reviews among authors of various IEEE journals, RBME addresses this need by receiving, reviewing, and publishing scholarly works under one umbrella. It covers a broad spectrum, from historical to modern developments in biomedical engineering and the integration of technologies from various IEEE societies into the life sciences and medicine.