Towards Clinical Translation: Establishing Optimal Dose and Dose-Rate Parameters for the FLASH Skin-Sparing Effect.

IF 2.8 4区 医学 Q3 PHARMACOLOGY & PHARMACY
Dose-Response Pub Date : 2025-11-29 eCollection Date: 2025-10-01 DOI:10.1177/15593258251401947
Yufeng Shen, Jie Zhou, Jinyi Lang, Lintao Li, Yongjie Li, Chenxi Yang, Shuo Wang, Xiaohua Chen, Siyu Xie, Wei Tang, Shun Lu
{"title":"Towards Clinical Translation: Establishing Optimal Dose and Dose-Rate Parameters for the FLASH Skin-Sparing Effect.","authors":"Yufeng Shen, Jie Zhou, Jinyi Lang, Lintao Li, Yongjie Li, Chenxi Yang, Shuo Wang, Xiaohua Chen, Siyu Xie, Wei Tang, Shun Lu","doi":"10.1177/15593258251401947","DOIUrl":null,"url":null,"abstract":"<p><strong>Purpose: </strong>FLASH radiotherapy (FLASH-RT) has been reported to spare skin from acute radiation toxicity. However, systematic quantification is needed to determine the dose and dose-rate thresholds necessary for optimal radioprotection in FLASH radiotherapy.</p><p><strong>Materials and methods: </strong>The hind limbs of male C57BL/6J mice were irradiated with a single-fraction dose (18-24 Gy) delivered using either FLASH-RT (ultrahigh dose rate: 250 Gy/s) or conventional radiotherapy (CONV-RT: 0.1 Gy/s) in the dose optimization experiment. Subsequent studies included a dose-rate optimization trial comparing FLASH-RT (40-400 Gy/s) with CONV-RT at 20 Gy; the antitumor efficacy of a single 20 Gy dose delivered via FLASH-RT (300 Gy/s) was compared with that of CONV-RT; and an assessment of the reirradiation response using FLASH-RT (400 Gy/s) or CONV-RT at 20 Gy following a prior hypofractionated CONV-RT regimen (9 Gy × 4). Skin injury scores, tumor volume, and body weight were monitored longitudinally for up to 30 days after irradiation or until the experimental endpoint was reached. Tumor weight and lung metastasis nodules were measured at the endpoint.</p><p><strong>Results: </strong>Dry desquamation, alopecia, moist desquamation, hemorrhage, full-thickness necrosis, and ulceration were observed more frequently in the CONV-RT group than in the FLASH-RT group. Compared with CONV-RT, FLASH-RT resulted in significantly lower acute skin injury scores at doses ≤22 Gy (18 Gy, 20 Gy, 22 Gy, <i>P</i> < 0.001), but this protective effect was absent at doses ≥24 Gy. Dose-rate optimization (40-400 Gy/s) delivering a 20 Gy dose revealed that acute skin injury scores were significantly reduced only at the higher dose-rates (≥300 Gy/s, compared with CONV-RT, <i>P</i> < 0.001), whereas no significant reduction was observed at the lower dose-rates (≤200 Gy/s, <i>P</i> ≥ 0.05). No additional benefit was detected between 300 Gy/s and 400 Gy/s. Although 250 Gy/s provided significant radioprotection compared with CONV-RT (<i>P</i> < 0.01), it was not the minimal rate required for maximal protection, as evidenced by a significantly better outcome at 300 Gy/s at 24 days (<i>P</i> = 0.0296). Finally, in B16/F10 cell-transplanted mouse models, FLASH-RT (300 and 400 Gy/s) achieved tumor control equivalent to that of CONV-RT while also reducing lung metastasis nodules and significantly mitigating acute skin toxicity (<i>P</i> < 0.001) during reirradiation.</p><p><strong>Conclusions: </strong>In this study, a dual-threshold framework was established to guide the clinical implementation of FLASH radiotherapy: a dose ceiling below 24 Gy to preserve the skin-sparing effect and a dose-rate threshold exceeding 200 Gy/s for efficacy, with further optimization achieved at rates above 250 Gy/s. These findings provide ​guidelines for minimizing radiotherapy-induced acute skin toxicity while maintaining comparable antitumor efficacy, thereby outlining a translatable pathway towards the clinical translation of FLASH-RT.</p>","PeriodicalId":11285,"journal":{"name":"Dose-Response","volume":"23 4","pages":"15593258251401947"},"PeriodicalIF":2.8000,"publicationDate":"2025-11-29","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC12665010/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Dose-Response","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1177/15593258251401947","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2025/10/1 0:00:00","PubModel":"eCollection","JCR":"Q3","JCRName":"PHARMACOLOGY & PHARMACY","Score":null,"Total":0}
引用次数: 0

Abstract

Purpose: FLASH radiotherapy (FLASH-RT) has been reported to spare skin from acute radiation toxicity. However, systematic quantification is needed to determine the dose and dose-rate thresholds necessary for optimal radioprotection in FLASH radiotherapy.

Materials and methods: The hind limbs of male C57BL/6J mice were irradiated with a single-fraction dose (18-24 Gy) delivered using either FLASH-RT (ultrahigh dose rate: 250 Gy/s) or conventional radiotherapy (CONV-RT: 0.1 Gy/s) in the dose optimization experiment. Subsequent studies included a dose-rate optimization trial comparing FLASH-RT (40-400 Gy/s) with CONV-RT at 20 Gy; the antitumor efficacy of a single 20 Gy dose delivered via FLASH-RT (300 Gy/s) was compared with that of CONV-RT; and an assessment of the reirradiation response using FLASH-RT (400 Gy/s) or CONV-RT at 20 Gy following a prior hypofractionated CONV-RT regimen (9 Gy × 4). Skin injury scores, tumor volume, and body weight were monitored longitudinally for up to 30 days after irradiation or until the experimental endpoint was reached. Tumor weight and lung metastasis nodules were measured at the endpoint.

Results: Dry desquamation, alopecia, moist desquamation, hemorrhage, full-thickness necrosis, and ulceration were observed more frequently in the CONV-RT group than in the FLASH-RT group. Compared with CONV-RT, FLASH-RT resulted in significantly lower acute skin injury scores at doses ≤22 Gy (18 Gy, 20 Gy, 22 Gy, P < 0.001), but this protective effect was absent at doses ≥24 Gy. Dose-rate optimization (40-400 Gy/s) delivering a 20 Gy dose revealed that acute skin injury scores were significantly reduced only at the higher dose-rates (≥300 Gy/s, compared with CONV-RT, P < 0.001), whereas no significant reduction was observed at the lower dose-rates (≤200 Gy/s, P ≥ 0.05). No additional benefit was detected between 300 Gy/s and 400 Gy/s. Although 250 Gy/s provided significant radioprotection compared with CONV-RT (P < 0.01), it was not the minimal rate required for maximal protection, as evidenced by a significantly better outcome at 300 Gy/s at 24 days (P = 0.0296). Finally, in B16/F10 cell-transplanted mouse models, FLASH-RT (300 and 400 Gy/s) achieved tumor control equivalent to that of CONV-RT while also reducing lung metastasis nodules and significantly mitigating acute skin toxicity (P < 0.001) during reirradiation.

Conclusions: In this study, a dual-threshold framework was established to guide the clinical implementation of FLASH radiotherapy: a dose ceiling below 24 Gy to preserve the skin-sparing effect and a dose-rate threshold exceeding 200 Gy/s for efficacy, with further optimization achieved at rates above 250 Gy/s. These findings provide ​guidelines for minimizing radiotherapy-induced acute skin toxicity while maintaining comparable antitumor efficacy, thereby outlining a translatable pathway towards the clinical translation of FLASH-RT.

Abstract Image

Abstract Image

Abstract Image

迈向临床转化:建立FLASH皮肤保护效果的最佳剂量和剂量率参数。
目的:据报道,FLASH放射治疗(FLASH- rt)可使皮肤免于急性辐射毒性。然而,需要系统的量化来确定FLASH放疗中最佳放射防护所需的剂量和剂量率阈值。材料与方法:在剂量优化实验中,采用FLASH-RT(超高剂量率:250 Gy/s)或常规放疗(convr - rt: 0.1 Gy/s)对雄性C57BL/6J小鼠后肢进行单次剂量(18-24 Gy)照射。随后的研究包括比较FLASH-RT (40-400 Gy/s)和convr - rt (20 Gy)的剂量率优化试验;通过FLASH-RT (300 Gy/s)单次给药20 Gy的抗肿瘤效果与convr - rt进行比较;在先前的低分割的convrt治疗方案(9 Gy × 4)之后,使用FLASH-RT (400 Gy/s)或20 Gy的convrt评估再照射反应。皮肤损伤评分、肿瘤体积和体重在照射后30天或实验终点前进行纵向监测。在终点测量肿瘤重量和肺转移结节。结果:干性脱屑、脱发、湿性脱屑、出血、全层坏死、溃疡的发生率在convr - rt组高于FLASH-RT组。与convrt相比,FLASH-RT在剂量≤22 Gy时显著降低急性皮肤损伤评分(18 Gy, 20 Gy, 22 Gy, P < 0.001),但在剂量≥24 Gy时不存在这种保护作用。剂量率优化(40-400 Gy/s)显示,只有在较高剂量率(≥300 Gy/s,与convr - rt相比,P < 0.001)下,急性皮肤损伤评分才会显著降低,而在较低剂量率(≤200 Gy/s, P≥0.05)下,急性皮肤损伤评分没有显著降低。在300 Gy/s和400 Gy/s之间没有检测到额外的益处。尽管与convr - rt相比,250 Gy/s提供了显著的放射防护(P < 0.01),但这并不是获得最大防护所需的最小速率,在24天时300 Gy/s的结果明显更好(P = 0.0296)。最后,在B16/F10细胞移植小鼠模型中,FLASH-RT(300和400 Gy/s)达到了与convr - rt相当的肿瘤控制效果,同时也减少了肺转移结节,显著减轻了再照射时的急性皮肤毒性(P < 0.001)。结论:本研究建立了双阈值框架来指导FLASH放疗的临床实施:剂量上限低于24 Gy以保持皮肤保留效果,剂量率阈值超过200 Gy/s以保持疗效,剂量率高于250 Gy/s时进一步优化。这些发现为尽量减少放疗引起的急性皮肤毒性,同时保持相当的抗肿瘤疗效提供了指导,从而概述了FLASH-RT临床翻译的可翻译途径。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
Dose-Response
Dose-Response PHARMACOLOGY & PHARMACY-RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING
CiteScore
4.90
自引率
4.00%
发文量
140
审稿时长
>12 weeks
期刊介绍: Dose-Response is an open access peer-reviewed online journal publishing original findings and commentaries on the occurrence of dose-response relationships across a broad range of disciplines. Particular interest focuses on experimental evidence providing mechanistic understanding of nonlinear dose-response relationships.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信
小红书