{"title":"A Nonrandomized, Comparative Case Series of Combined Phacoemulsification with iStent Inject W and OMNI Surgical System","authors":"Ethan Wen Wei Tiong MBChB , Aysha Salam MBBS , Navanandhanan Pradeesh MBChB , Imran Masood MBBS","doi":"10.1016/j.ogla.2025.11.005","DOIUrl":null,"url":null,"abstract":"<div><h3>Purpose</h3><div>To compare efficacy and safety outcomes of phacoemulsification combined with either iStent inject W or OMNI surgical system with different degrees of gonioscopy-assisted transluminal trabeculotomy (GATT) in patients with glaucoma.</div></div><div><h3>Design</h3><div>Single-center, retrospective, nonrandomized comparative cohort study.</div></div><div><h3>Subjects</h3><div>Consecutive cases that underwent phacoemulsification combined with either iStent inject W or OMNI surgical system with at least 12-month follow-up.</div></div><div><h3>Methods</h3><div>Single-center retrospective comparative cohort study comparing outcomes between 3 groups: phacoemulsification with iStent inject W (phaco-iStent) or OMNI with either 90° to 180° (phaco-OG [OMNI and GATT]180) or >180° to 360° (phaco-OG360) of GATT.</div></div><div><h3>Main Outcome Measures</h3><div>Success at 12 months is defined as medication-free with either a 20% intraocular pressure (IOP) reduction or IOP ≤18 mmHg. Primary outcomes were IOP and the number of glaucoma medications. Secondary outcomes included complications and the need for further glaucoma surgery.</div></div><div><h3>Results</h3><div>A total of 294 eyes (phaco-iStent, 135; phaco-OG180, 39; phaco-OG360, 120) of 250 patients were included with similar baseline IOP (18 mmHg, <em>P</em> = 0.91) and medications (2.04 vs. 1.67 vs. 2.01, <em>P</em> = 0.22) across groups. Significant reductions in IOP and number of glaucoma medications were observed across all 3 groups (<em>P</em> < 0.0014), although no significant differences were found between procedures for any outcome measure. Success rates were 25.2%, 38.5%, and 32.5%, whereas medication-free rates were 28.1%, 38.5%, and 35.0% for the phaco-iStent, phaco-OG180, and phaco-OG360 groups, respectively, without significant differences. Phaco-OG360 achieved significantly higher rates of medication-free IOP reductions of ≥30% compared with phaco-iStent (<em>P</em> = 0.013) in exploratory analysis. Complications were more frequent in the phaco-OG180 and phaco-OG360 groups compared with the phaco-iStent group, with higher rates of microhyphema (5.1% and 10.8% vs. 0.7%) and layered hyphema (12.8% and 4.2% vs. 0.7%), respectively. One eye in the phaco-OG360 group underwent a trabeculectomy at 6 months.</div></div><div><h3>Conclusions</h3><div>All procedures significantly reduced IOP and medication burden, with no significant difference in overall success rates. Phaco-iStent has a better safety profile, although phaco-OMNI may provide higher rates of medication-free IOP reduction. Outcomes between 180° and 360° of GATT were similar, suggesting limited additional benefit from extending trabeculotomy. These findings may help guide decision-making in combined phacoemulsification and canal-based minimally invasive glaucoma surgery.</div></div><div><h3>Financial Disclosure(s)</h3><div>Proprietary or commercial disclosure may be found in the Footnotes and Disclosures at the end of this article.</div></div>","PeriodicalId":19519,"journal":{"name":"Ophthalmology. Glaucoma","volume":"9 3","pages":"Pages 267-275"},"PeriodicalIF":3.3000,"publicationDate":"2026-05-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Ophthalmology. Glaucoma","FirstCategoryId":"1085","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S2589419625002443","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2025/11/29 0:00:00","PubModel":"Epub","JCR":"Q1","JCRName":"OPHTHALMOLOGY","Score":null,"Total":0}
引用次数: 0
Abstract
Purpose
To compare efficacy and safety outcomes of phacoemulsification combined with either iStent inject W or OMNI surgical system with different degrees of gonioscopy-assisted transluminal trabeculotomy (GATT) in patients with glaucoma.
Consecutive cases that underwent phacoemulsification combined with either iStent inject W or OMNI surgical system with at least 12-month follow-up.
Methods
Single-center retrospective comparative cohort study comparing outcomes between 3 groups: phacoemulsification with iStent inject W (phaco-iStent) or OMNI with either 90° to 180° (phaco-OG [OMNI and GATT]180) or >180° to 360° (phaco-OG360) of GATT.
Main Outcome Measures
Success at 12 months is defined as medication-free with either a 20% intraocular pressure (IOP) reduction or IOP ≤18 mmHg. Primary outcomes were IOP and the number of glaucoma medications. Secondary outcomes included complications and the need for further glaucoma surgery.
Results
A total of 294 eyes (phaco-iStent, 135; phaco-OG180, 39; phaco-OG360, 120) of 250 patients were included with similar baseline IOP (18 mmHg, P = 0.91) and medications (2.04 vs. 1.67 vs. 2.01, P = 0.22) across groups. Significant reductions in IOP and number of glaucoma medications were observed across all 3 groups (P < 0.0014), although no significant differences were found between procedures for any outcome measure. Success rates were 25.2%, 38.5%, and 32.5%, whereas medication-free rates were 28.1%, 38.5%, and 35.0% for the phaco-iStent, phaco-OG180, and phaco-OG360 groups, respectively, without significant differences. Phaco-OG360 achieved significantly higher rates of medication-free IOP reductions of ≥30% compared with phaco-iStent (P = 0.013) in exploratory analysis. Complications were more frequent in the phaco-OG180 and phaco-OG360 groups compared with the phaco-iStent group, with higher rates of microhyphema (5.1% and 10.8% vs. 0.7%) and layered hyphema (12.8% and 4.2% vs. 0.7%), respectively. One eye in the phaco-OG360 group underwent a trabeculectomy at 6 months.
Conclusions
All procedures significantly reduced IOP and medication burden, with no significant difference in overall success rates. Phaco-iStent has a better safety profile, although phaco-OMNI may provide higher rates of medication-free IOP reduction. Outcomes between 180° and 360° of GATT were similar, suggesting limited additional benefit from extending trabeculotomy. These findings may help guide decision-making in combined phacoemulsification and canal-based minimally invasive glaucoma surgery.
Financial Disclosure(s)
Proprietary or commercial disclosure may be found in the Footnotes and Disclosures at the end of this article.