{"title":"Research on quantitative assessment of renal tubular function based on renal dynamic imaging","authors":"W. Liu, G. Yao, Y. Gao, C. Wang","doi":"10.1016/j.remnie.2025.500268","DOIUrl":null,"url":null,"abstract":"<div><h3>Objective</h3><div>To establish a renal tubular uptake rate (RTUR) model based on renal dynamic imaging (RDI) for detecting early tubular injury and to explore its clinical application value.</div></div><div><h3>Materials and methods</h3><div>RDI data collected from August 2020 to June 2025 were analyzed. A total of 292 eligible cases (441 kidneys) were included. Participants were categorized into: - Control group: 56 cases (112 kidneys) - Renal insufficiency group: 93 cases (186 kidneys) - Fully compensated group: 62 cases (62 kidneys) - Partially compensated group: 35 cases (35 kidneys) - Decompensated group: 46 cases (46 kidneys).</div></div><div><h3>RTUR calculation formula</h3><div>RTUR = (Ascent slope of renal scintigraphy/Total injected radioactive drug activity) × 10<sup>5</sup> × 100%.</div></div><div><h3>Analysis content</h3><div>Distribution of RTUR values across five groups; correlation between GFR and RTUR in 441 kidneys. Differences in RTUR between the control group and other four groups; diagnostic efficacy and clinical value of RTUR.</div></div><div><h3>Results</h3><div>Compared with the control group, significant differences in RTUR were observed in the renal insufficiency group, fully compensated group, and decompensated group (<em>P</em> < .01). GFR in 441 kidneys showed a strong positive correlation with RTUR (r = 0.739, <em>P</em> < .001). ROC analysis indicated that RTUR ≤ 5.225% identified renal insufficiency (sensitivity 77.7%, specificity 70.4%), while RTUR ≥ 9.135% diagnosed complete renal compensation with 82.3% sensitivity.</div></div><div><h3>Conclusion</h3><div>The RTUR model enables stable quantitative assessment of renal tubular reabsorption rate, facilitating diagnosis of renal insufficiency and complete renal compensation. It holds promise as a novel quantitative indicator for evaluating tubular function. Renal GFR exhibits a strong correlation with RTUR.</div></div>","PeriodicalId":94197,"journal":{"name":"Revista espanola de medicina nuclear e imagen molecular","volume":"45 3","pages":"Article 500268"},"PeriodicalIF":0.0000,"publicationDate":"2026-05-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Revista espanola de medicina nuclear e imagen molecular","FirstCategoryId":"1085","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S2253808925001740","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2025/11/28 0:00:00","PubModel":"Epub","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0
Abstract
Objective
To establish a renal tubular uptake rate (RTUR) model based on renal dynamic imaging (RDI) for detecting early tubular injury and to explore its clinical application value.
Materials and methods
RDI data collected from August 2020 to June 2025 were analyzed. A total of 292 eligible cases (441 kidneys) were included. Participants were categorized into: - Control group: 56 cases (112 kidneys) - Renal insufficiency group: 93 cases (186 kidneys) - Fully compensated group: 62 cases (62 kidneys) - Partially compensated group: 35 cases (35 kidneys) - Decompensated group: 46 cases (46 kidneys).
RTUR calculation formula
RTUR = (Ascent slope of renal scintigraphy/Total injected radioactive drug activity) × 105 × 100%.
Analysis content
Distribution of RTUR values across five groups; correlation between GFR and RTUR in 441 kidneys. Differences in RTUR between the control group and other four groups; diagnostic efficacy and clinical value of RTUR.
Results
Compared with the control group, significant differences in RTUR were observed in the renal insufficiency group, fully compensated group, and decompensated group (P < .01). GFR in 441 kidneys showed a strong positive correlation with RTUR (r = 0.739, P < .001). ROC analysis indicated that RTUR ≤ 5.225% identified renal insufficiency (sensitivity 77.7%, specificity 70.4%), while RTUR ≥ 9.135% diagnosed complete renal compensation with 82.3% sensitivity.
Conclusion
The RTUR model enables stable quantitative assessment of renal tubular reabsorption rate, facilitating diagnosis of renal insufficiency and complete renal compensation. It holds promise as a novel quantitative indicator for evaluating tubular function. Renal GFR exhibits a strong correlation with RTUR.