{"title":"Automated Segmentation of Liver and Liver Tumors with SwinUNETR and UNET Neural Networks on <sup>18</sup>F-FDG PET/CT.","authors":"Burak Demir, Hatice Kübra Yurtçu, Merve Ağcıoğlu Atalay, Fikret Ertek","doi":"10.4274/mirt.galenos.2025.58751","DOIUrl":null,"url":null,"abstract":"<p><strong>Objectives: </strong>To develop and evaluate automated segmentation models for the liver and hepatic tumors on <sup>18</sup>F-fluorodeoxyglucose positron emission tomography/computed tomography (<sup>18</sup>F-FDG PET/CT) using SwinUNETR and residual UNET architectures, and to assess their accuracy in complex clinical cases.</p><p><strong>Methods: </strong>In this single-center retrospective study, 100 patients (48 males, 52 females; mean age 61±14 years) with <sup>18</sup>F-FDG-avid hepatic lesions from various primary malignancies were included. Liver segmentation was performed on non-contrast CT images using pairs of SwinUNETR and residual UNET models, and tumor segmentation was performed on masked PET images using separately trained pair of SwinUNETR and residual UNET model. Model performance was evaluated using the dice similarity coefficient (DSC), volumetric bias, and Bland-Altman analysis for metabolic tumor volume (MTV) and total lesion glycolysis (TLG).</p><p><strong>Results: </strong>For liver segmentation, SwinUNETR achieved a median DSC of 97.59% (range: 95.41-98.93%) with a median volumetric bias of -0.94% (LoA: -3.76% to +0.50%), while residual UNET achieved a median DSC of 97.85% (range: 94.81-98.80%) with a median volumetric bias of -0.34% (LoA: -2.63% to +1.16%). For tumor segmentation, SwinUNETR achieved a median DSC of 92.62% (range: 80.75-97.46%), an MTV bias of -8.60% (LoA: -31.62% to +1.21%), and a TLG bias of -6.40% (LoA: -25.58% to +0.76%). Residual UNET achieved a median DSC of 93.07% (range: 80.74-98.18%), MTV bias of -4.33% (LoA: -24.36% to +10.12%), and TLG bias of -11.10% (LoA: -30.8% to +4.52%). Most MTV and TLG measurements were within ±10% of reference values.</p><p><strong>Conclusion: </strong>Both SwinUNETR and Residual UNET achieved excellent liver segmentation accuracy and clinically acceptable tumor segmentation performance on <sup>18</sup>F-FDG PET/CT, with SwinUNETR showing slightly better performance in liver volumetric measurements. These open-source models could be integrated into clinical workflows to automate segmentation tasks, facilitate treatment planning for liver-directed therapies, and support reproducible quantitative imaging analyses.</p>","PeriodicalId":44681,"journal":{"name":"Molecular Imaging and Radionuclide Therapy","volume":" ","pages":"10-18"},"PeriodicalIF":0.9000,"publicationDate":"2026-02-03","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC12869095/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Molecular Imaging and Radionuclide Therapy","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.4274/mirt.galenos.2025.58751","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2025/12/1 0:00:00","PubModel":"Epub","JCR":"Q4","JCRName":"RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING","Score":null,"Total":0}
引用次数: 0
Abstract
Objectives: To develop and evaluate automated segmentation models for the liver and hepatic tumors on 18F-fluorodeoxyglucose positron emission tomography/computed tomography (18F-FDG PET/CT) using SwinUNETR and residual UNET architectures, and to assess their accuracy in complex clinical cases.
Methods: In this single-center retrospective study, 100 patients (48 males, 52 females; mean age 61±14 years) with 18F-FDG-avid hepatic lesions from various primary malignancies were included. Liver segmentation was performed on non-contrast CT images using pairs of SwinUNETR and residual UNET models, and tumor segmentation was performed on masked PET images using separately trained pair of SwinUNETR and residual UNET model. Model performance was evaluated using the dice similarity coefficient (DSC), volumetric bias, and Bland-Altman analysis for metabolic tumor volume (MTV) and total lesion glycolysis (TLG).
Results: For liver segmentation, SwinUNETR achieved a median DSC of 97.59% (range: 95.41-98.93%) with a median volumetric bias of -0.94% (LoA: -3.76% to +0.50%), while residual UNET achieved a median DSC of 97.85% (range: 94.81-98.80%) with a median volumetric bias of -0.34% (LoA: -2.63% to +1.16%). For tumor segmentation, SwinUNETR achieved a median DSC of 92.62% (range: 80.75-97.46%), an MTV bias of -8.60% (LoA: -31.62% to +1.21%), and a TLG bias of -6.40% (LoA: -25.58% to +0.76%). Residual UNET achieved a median DSC of 93.07% (range: 80.74-98.18%), MTV bias of -4.33% (LoA: -24.36% to +10.12%), and TLG bias of -11.10% (LoA: -30.8% to +4.52%). Most MTV and TLG measurements were within ±10% of reference values.
Conclusion: Both SwinUNETR and Residual UNET achieved excellent liver segmentation accuracy and clinically acceptable tumor segmentation performance on 18F-FDG PET/CT, with SwinUNETR showing slightly better performance in liver volumetric measurements. These open-source models could be integrated into clinical workflows to automate segmentation tasks, facilitate treatment planning for liver-directed therapies, and support reproducible quantitative imaging analyses.
期刊介绍:
Molecular Imaging and Radionuclide Therapy (Mol Imaging Radionucl Ther, MIRT) is publishes original research articles, invited reviews, editorials, short communications, letters, consensus statements, guidelines and case reports with a literature review on the topic, in the field of molecular imaging, multimodality imaging, nuclear medicine, radionuclide therapy, radiopharmacy, medical physics, dosimetry and radiobiology.