Middle Ear Transfer Function for Sound Conduction Study of Middle Ear Implants: A New Method.

Journal of otology Pub Date : 2025-11-13 eCollection Date: 2025-10-01 DOI:10.26599/JOTO.2025.9540034
Yueqi Li, Xiao Qin, Guodong Feng, Zhiqiang Gao
{"title":"Middle Ear Transfer Function for Sound Conduction Study of Middle Ear Implants: A New Method.","authors":"Yueqi Li, Xiao Qin, Guodong Feng, Zhiqiang Gao","doi":"10.26599/JOTO.2025.9540034","DOIUrl":null,"url":null,"abstract":"<p><p>Human temporal bone specimens are used in experiments to measure the sound transfer function of the middle ear. This standard method for the development of middle ear implants requires temporal bones that possess appropriate mechanical properties and structural stability and are free from pathological conditions. A laser Doppler vibrometer is commonly employed to measure the vibration of the stapes footplate. These experiments are typically conducted in the middle ear by leaving the inner ear intact, exposing the stapes footplate through the tympanic cavity, and directing the laser beam onto the footplate. However, previous studies have shown that the influence of inner ear impedance on the middle ear transfer function cannot be ignored, and any surgical manipulation may cause a change in inner ear pressure, resulting in instability in the middle ear transfer function. Therefore, this study aims to eliminate the influence of the inner ear and to establish a new experimental method in human temporal bone specimens that is more suitable for the study of sound conduction in middle ear implants. As a result, a range for middle ear transfer function was developed, which serves as a reference for assessing the conformity of temporal bone specimens to experimental standards, and the stability of this range was demonstrated under experimental conditions.</p>","PeriodicalId":94336,"journal":{"name":"Journal of otology","volume":"20 4","pages":"219-224"},"PeriodicalIF":0.0000,"publicationDate":"2025-11-13","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC12647957/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of otology","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.26599/JOTO.2025.9540034","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2025/10/1 0:00:00","PubModel":"eCollection","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

Human temporal bone specimens are used in experiments to measure the sound transfer function of the middle ear. This standard method for the development of middle ear implants requires temporal bones that possess appropriate mechanical properties and structural stability and are free from pathological conditions. A laser Doppler vibrometer is commonly employed to measure the vibration of the stapes footplate. These experiments are typically conducted in the middle ear by leaving the inner ear intact, exposing the stapes footplate through the tympanic cavity, and directing the laser beam onto the footplate. However, previous studies have shown that the influence of inner ear impedance on the middle ear transfer function cannot be ignored, and any surgical manipulation may cause a change in inner ear pressure, resulting in instability in the middle ear transfer function. Therefore, this study aims to eliminate the influence of the inner ear and to establish a new experimental method in human temporal bone specimens that is more suitable for the study of sound conduction in middle ear implants. As a result, a range for middle ear transfer function was developed, which serves as a reference for assessing the conformity of temporal bone specimens to experimental standards, and the stability of this range was demonstrated under experimental conditions.

中耳传递函数用于中耳植入物声传导研究的新方法。
实验采用人颞骨标本测量中耳的声音传递函数。这种中耳植入物发育的标准方法要求颞骨具有适当的机械性能和结构稳定性,并且没有病理状况。激光多普勒测振仪通常用于镫骨踏板的振动测量。这些实验通常在中耳中进行,保持内耳完整,通过鼓室暴露镫骨踏板,并将激光束引导到踏板上。然而,以往的研究表明,内耳阻抗对中耳传递功能的影响不容忽视,任何手术操作都可能引起内耳压力的变化,导致中耳传递功能的不稳定。因此,本研究旨在消除内耳的影响,在人颞骨标本中建立一种更适合中耳植入物声传导研究的新实验方法。由此建立了一个中耳传递函数范围,作为评估颞骨标本与实验标准一致性的参考,并在实验条件下证明了该范围的稳定性。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信
小红书