Experimental approach for optimizing dose regimen of 68Ga-DOTATATE PET/CT for neuroendocrine tumor (NET) imaging in current high sensitivity scanners: Phantom and Patient Study.

IF 1.2
Nuklearmedizin. Nuclear medicine Pub Date : 2025-12-01 Epub Date: 2025-11-26 DOI:10.1055/a-2710-7001
Abbas Monsef, Fatemeh Saboktakin, Fatemeh Sadeghi, Mohammadreza Elhaie, Mohsen Beheshti, Peyman Sheikhzadeh
{"title":"Experimental approach for optimizing dose regimen of 68Ga-DOTATATE PET/CT for neuroendocrine tumor (NET) imaging in current high sensitivity scanners: Phantom and Patient Study.","authors":"Abbas Monsef, Fatemeh Saboktakin, Fatemeh Sadeghi, Mohammadreza Elhaie, Mohsen Beheshti, Peyman Sheikhzadeh","doi":"10.1055/a-2710-7001","DOIUrl":null,"url":null,"abstract":"<p><p>This study aimed to determine the optimized scan time and injected activity regimen for clinical <sup>68</sup>Ga DOTATATE PET/CT in neuroendocrine tumor imaging through an experimental approach without using machine learning techniques.A NEMA PET body phantom was used with Ga-<sup>68</sup> to simulate a 9:1 sphere-to-background ratio. PET data were acquired on a high-sensitivity scanner at various scan times (15-300 s/bed). For each scan time, coefficient of variation (COV) and contrast-to-noise ratio (CNR) were calculated. The minimum scan time (T<sub>min</sub>) needed to meet the Rose Criterion (CNR > 5) for the smallest sphere was identified. This T<sub>min</sub> was then applied to patient scans with neuroendocrine tumors (originally acquired at 120 s/bed) to evaluate image quality and determine an optimized activity regimen for clinical <sup>68</sup>Ga-DOTATATE PET imaging.Phantom experiments showed that a COV<sub>max</sub> of 20% is the highest acceptable noise level for detecting the smallest lesions, corresponding to a minimum scan time of about 1 minute per bed position. Patient image analysis confirmed that all tumors visible at routine scan times were still detectable at this minimum duration. This supports the use of a lower activity regimen (~1 MBq/kg), which can reduce patient radiation exposure compared to the standard 1.85 MBq/kg protocol.This work demonstrated that scan time and activity for <sup>68</sup>Ga-DOTATATE NET imaging can be significantly minimized without compromising image interpretation and quantification.</p>","PeriodicalId":94161,"journal":{"name":"Nuklearmedizin. Nuclear medicine","volume":"64 6","pages":"341-351"},"PeriodicalIF":1.2000,"publicationDate":"2025-12-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Nuklearmedizin. Nuclear medicine","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1055/a-2710-7001","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2025/11/26 0:00:00","PubModel":"Epub","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

This study aimed to determine the optimized scan time and injected activity regimen for clinical 68Ga DOTATATE PET/CT in neuroendocrine tumor imaging through an experimental approach without using machine learning techniques.A NEMA PET body phantom was used with Ga-68 to simulate a 9:1 sphere-to-background ratio. PET data were acquired on a high-sensitivity scanner at various scan times (15-300 s/bed). For each scan time, coefficient of variation (COV) and contrast-to-noise ratio (CNR) were calculated. The minimum scan time (Tmin) needed to meet the Rose Criterion (CNR > 5) for the smallest sphere was identified. This Tmin was then applied to patient scans with neuroendocrine tumors (originally acquired at 120 s/bed) to evaluate image quality and determine an optimized activity regimen for clinical 68Ga-DOTATATE PET imaging.Phantom experiments showed that a COVmax of 20% is the highest acceptable noise level for detecting the smallest lesions, corresponding to a minimum scan time of about 1 minute per bed position. Patient image analysis confirmed that all tumors visible at routine scan times were still detectable at this minimum duration. This supports the use of a lower activity regimen (~1 MBq/kg), which can reduce patient radiation exposure compared to the standard 1.85 MBq/kg protocol.This work demonstrated that scan time and activity for 68Ga-DOTATATE NET imaging can be significantly minimized without compromising image interpretation and quantification.

68Ga-DOTATATE PET/CT在当前高灵敏度扫描仪中用于神经内分泌肿瘤(NET)成像的剂量方案优化实验方法:幻影和患者研究。
本研究旨在通过实验方法确定临床68Ga DOTATATE PET/CT在神经内分泌肿瘤成像中的最佳扫描时间和注射活动方案,而不使用机器学习技术。使用Ga-68的NEMA PET体模模拟9:1的球背景比。PET数据在不同扫描时间(15-300秒/床)的高灵敏度扫描仪上获得。在每个扫描时间内,计算变异系数(COV)和噪比(CNR)。确定了最小球体满足玫瑰准则(CNR > 5)所需的最小扫描时间(Tmin)。然后将该Tmin应用于神经内分泌肿瘤患者扫描(最初以120秒/床的速度获得),以评估图像质量并确定临床68Ga-DOTATATE PET成像的优化活动方案。幻影实验表明,20%的COVmax是检测最小病变的最高可接受噪声水平,对应于每个床位的最小扫描时间约为1分钟。患者图像分析证实,在这个最短时间内,在常规扫描时间内可见的所有肿瘤仍然可以检测到。这支持使用低活动方案(~1 MBq/kg),与标准的1.85 MBq/kg方案相比,可以减少患者的辐射暴露。这项工作表明,68Ga-DOTATATE NET成像的扫描时间和活动可以在不影响图像解释和量化的情况下显着最小化。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信
小红书