{"title":"Effect of stent-graft length and compliance on aortic hemodynamics in a bench-top physiological flow circuit","authors":"Ramin Shahbad, Elizabeth Zermeno, Sayed Ahmadreza Razian, Kaspars Maleckis, Majid Jadidi, Anastasia Desyatova","doi":"10.1016/j.jmbbm.2025.107269","DOIUrl":null,"url":null,"abstract":"<div><div>The aortic elasticity plays a vital role in buffering pulsatile blood flow, propelling blood to distal organs and the heart, and reducing cardiac workload. Aortic repair with a stent-graft can reduce this elasticity and hinder the aorta's ability to effectively perform its function. Conventional stent-grafts are associated with increased arterial stiffness, elevated pulse wave velocity (PWV), and adverse hemodynamic changes. This is largely driven by stiffness mismatch between the stent-graft and the native aortic wall, which alters mechanical compliance and hemodynamic response. This study evaluates a novel compliant nanofiber stent-graft (NF-SG) developed to closely mimic native aortic mechanics. Using a bench-top physiological flow circuit, we assessed the hemodynamic impacts of stent-graft stiffness and length on arterial parameters, including PWV, pulse pressure (PP), and distensibility in vitro, and compared these effects with conventional stent-grafts. Stent-graft stiffness significantly affected PWV, PP, and distensibility. Conventional stent-grafts showed 14 %–52 % increase in PWV depending on stent-graft length (p < 0.001), 5 %–32 % increase in PP, and 82 % reduction in mid-graft distensibility. In contrast, NF-SGs maintained PWV and PP near baseline levels with marginal effect of the stent-graft length. Distensibility in the mid-graft was reduced by 13 %–20 %, depending on the stent-graft length. The NF-SG's superior compliance and reduced hemodynamic perturbation were attributed to its mechanically optimized fabric and skeleton design. These findings underscore the clinical potential of the compliant stent-grafts to significantly mitigate long-term cardiovascular complications and preserve aortic functionality post-intervention.</div></div>","PeriodicalId":380,"journal":{"name":"Journal of the Mechanical Behavior of Biomedical Materials","volume":"174 ","pages":"Article 107269"},"PeriodicalIF":4.1000,"publicationDate":"2026-02-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of the Mechanical Behavior of Biomedical Materials","FirstCategoryId":"5","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S1751616125003856","RegionNum":2,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2025/11/11 0:00:00","PubModel":"Epub","JCR":"Q2","JCRName":"ENGINEERING, BIOMEDICAL","Score":null,"Total":0}
引用次数: 0
Abstract
The aortic elasticity plays a vital role in buffering pulsatile blood flow, propelling blood to distal organs and the heart, and reducing cardiac workload. Aortic repair with a stent-graft can reduce this elasticity and hinder the aorta's ability to effectively perform its function. Conventional stent-grafts are associated with increased arterial stiffness, elevated pulse wave velocity (PWV), and adverse hemodynamic changes. This is largely driven by stiffness mismatch between the stent-graft and the native aortic wall, which alters mechanical compliance and hemodynamic response. This study evaluates a novel compliant nanofiber stent-graft (NF-SG) developed to closely mimic native aortic mechanics. Using a bench-top physiological flow circuit, we assessed the hemodynamic impacts of stent-graft stiffness and length on arterial parameters, including PWV, pulse pressure (PP), and distensibility in vitro, and compared these effects with conventional stent-grafts. Stent-graft stiffness significantly affected PWV, PP, and distensibility. Conventional stent-grafts showed 14 %–52 % increase in PWV depending on stent-graft length (p < 0.001), 5 %–32 % increase in PP, and 82 % reduction in mid-graft distensibility. In contrast, NF-SGs maintained PWV and PP near baseline levels with marginal effect of the stent-graft length. Distensibility in the mid-graft was reduced by 13 %–20 %, depending on the stent-graft length. The NF-SG's superior compliance and reduced hemodynamic perturbation were attributed to its mechanically optimized fabric and skeleton design. These findings underscore the clinical potential of the compliant stent-grafts to significantly mitigate long-term cardiovascular complications and preserve aortic functionality post-intervention.
期刊介绍:
The Journal of the Mechanical Behavior of Biomedical Materials is concerned with the mechanical deformation, damage and failure under applied forces, of biological material (at the tissue, cellular and molecular levels) and of biomaterials, i.e. those materials which are designed to mimic or replace biological materials.
The primary focus of the journal is the synthesis of materials science, biology, and medical and dental science. Reports of fundamental scientific investigations are welcome, as are articles concerned with the practical application of materials in medical devices. Both experimental and theoretical work is of interest; theoretical papers will normally include comparison of predictions with experimental data, though we recognize that this may not always be appropriate. The journal also publishes technical notes concerned with emerging experimental or theoretical techniques, letters to the editor and, by invitation, review articles and papers describing existing techniques for the benefit of an interdisciplinary readership.