Vibroacoustic detection of inclusions in an elastomeric tissue phantom using a multilayer perceptron classifier: A proof-of-concept study

IF 4.1 2区 医学 Q2 ENGINEERING, BIOMEDICAL
Mostafa Sayahkarajy , Florian Römer , Hartmut Witte
{"title":"Vibroacoustic detection of inclusions in an elastomeric tissue phantom using a multilayer perceptron classifier: A proof-of-concept study","authors":"Mostafa Sayahkarajy ,&nbsp;Florian Römer ,&nbsp;Hartmut Witte","doi":"10.1016/j.jmbbm.2025.107279","DOIUrl":null,"url":null,"abstract":"<div><div>Accurate detection of tumor boundaries is critical for the success of oncologic surgical intervention. Traditionally, palpation can handover important information for tumor localization based on the tissue mechanical properties, but in Minimally Invasive Surgery no direct access to the tumor for palpation is feasible. For providing a technical analogy, this feasibility-level study focusses on the simplified problem of detection of an inclusion within a homogeneous silicon phantom. We hypothesized that existence of a relatively stiffer inclusion within an elastomer tissue phantom changes vibroacoustic signatures under forced vibration conditions. In comparison with previous studies, in this work the measurement probe was static, and the short-time (1 s) data package analysis targeted at nearly real-time inclusion detection. The inclusion detection problem was cast into a binary classification of the short-time acquired vibroacoustic signals. The method involves a wavelet-based multilayer perceptron neural network (MLP) that is trained in a supervised manner. A micro-electro-mechanical system (MEMS) sensor proximally attached to a solid probe was used to measure the vibroacoustic signals. Phantoms of simulated healthy tissue with stiffer tumor model inclusions were used for experiments and data collection. From the 120 overall number of experiments, 15 % were used as test data to evaluate the performance. The results show inclusion detection F1 score of 75 %, and 77.8 % accuracy related to the confusion matrix, reflecting the model performance on previously unseen data. Performance of the classifier was discussed in terms of various binary classification metrics, and compared with another established classifier, support vector machine (SVM). While the results support the hypothesis of this proof-of-concept study, extensions like improving the electronic system and refining the method with more experiments on biological tissues remain as the future work.</div></div>","PeriodicalId":380,"journal":{"name":"Journal of the Mechanical Behavior of Biomedical Materials","volume":"174 ","pages":"Article 107279"},"PeriodicalIF":4.1000,"publicationDate":"2026-02-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of the Mechanical Behavior of Biomedical Materials","FirstCategoryId":"5","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S1751616125003959","RegionNum":2,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2025/11/19 0:00:00","PubModel":"Epub","JCR":"Q2","JCRName":"ENGINEERING, BIOMEDICAL","Score":null,"Total":0}
引用次数: 0

Abstract

Accurate detection of tumor boundaries is critical for the success of oncologic surgical intervention. Traditionally, palpation can handover important information for tumor localization based on the tissue mechanical properties, but in Minimally Invasive Surgery no direct access to the tumor for palpation is feasible. For providing a technical analogy, this feasibility-level study focusses on the simplified problem of detection of an inclusion within a homogeneous silicon phantom. We hypothesized that existence of a relatively stiffer inclusion within an elastomer tissue phantom changes vibroacoustic signatures under forced vibration conditions. In comparison with previous studies, in this work the measurement probe was static, and the short-time (1 s) data package analysis targeted at nearly real-time inclusion detection. The inclusion detection problem was cast into a binary classification of the short-time acquired vibroacoustic signals. The method involves a wavelet-based multilayer perceptron neural network (MLP) that is trained in a supervised manner. A micro-electro-mechanical system (MEMS) sensor proximally attached to a solid probe was used to measure the vibroacoustic signals. Phantoms of simulated healthy tissue with stiffer tumor model inclusions were used for experiments and data collection. From the 120 overall number of experiments, 15 % were used as test data to evaluate the performance. The results show inclusion detection F1 score of 75 %, and 77.8 % accuracy related to the confusion matrix, reflecting the model performance on previously unseen data. Performance of the classifier was discussed in terms of various binary classification metrics, and compared with another established classifier, support vector machine (SVM). While the results support the hypothesis of this proof-of-concept study, extensions like improving the electronic system and refining the method with more experiments on biological tissues remain as the future work.
使用多层感知器分类器对弹性组织模体中内含物的振动声检测:概念验证研究
肿瘤边界的准确检测是肿瘤外科干预成功的关键。传统上,触诊可以根据组织力学特性传递肿瘤定位的重要信息,但在微创外科中,无法直接进入肿瘤进行触诊。为了提供一个技术上的类比,这个可行性级别的研究侧重于在均匀硅模体中检测包含物的简化问题。我们假设在弹性体组织模体中存在相对较硬的内含物会在强制振动条件下改变振动声学特征。与以往的研究相比,本研究的测量探针是静态的,短时间(1 s)数据包分析的目标是近实时的内含物检测。将夹杂物检测问题转化为对短时间采集的振动声信号进行二值分类。该方法涉及一个基于小波的多层感知器神经网络(MLP),该网络以监督方式训练。采用近端附着在固体探针上的微机电系统(MEMS)传感器来测量振动声信号。采用模拟健康组织的模型和较硬的肿瘤模型包涵体进行实验和数据收集。从120个实验总数中,15%作为测试数据来评估性能。结果表明,包含检测F1得分为75%,与混淆矩阵相关的准确率为77.8%,反映了模型对以前未见过的数据的性能。根据各种二值分类指标讨论了分类器的性能,并与另一种已建立的分类器支持向量机(SVM)进行了比较。虽然结果支持这个概念验证研究的假设,但像改进电子系统和通过更多的生物组织实验来完善方法这样的扩展仍然是未来的工作。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
Journal of the Mechanical Behavior of Biomedical Materials
Journal of the Mechanical Behavior of Biomedical Materials 工程技术-材料科学:生物材料
CiteScore
7.20
自引率
7.70%
发文量
505
审稿时长
46 days
期刊介绍: The Journal of the Mechanical Behavior of Biomedical Materials is concerned with the mechanical deformation, damage and failure under applied forces, of biological material (at the tissue, cellular and molecular levels) and of biomaterials, i.e. those materials which are designed to mimic or replace biological materials. The primary focus of the journal is the synthesis of materials science, biology, and medical and dental science. Reports of fundamental scientific investigations are welcome, as are articles concerned with the practical application of materials in medical devices. Both experimental and theoretical work is of interest; theoretical papers will normally include comparison of predictions with experimental data, though we recognize that this may not always be appropriate. The journal also publishes technical notes concerned with emerging experimental or theoretical techniques, letters to the editor and, by invitation, review articles and papers describing existing techniques for the benefit of an interdisciplinary readership.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信
小红书