{"title":"A false reactive hepatitis B surface antigen result due to dislodged gel from Vacutainer.","authors":"Rajesh B Sawant, Yardi U Tanvi, Raees A Shaikh","doi":"10.4103/ajts.ajts_42_24","DOIUrl":null,"url":null,"abstract":"<p><p>Preanalytical variables play a key role in the correctness of laboratory test results. We report a false reactive result for hepatitis B surface antigen (HBsAg) on serological testing with a relatively low OD. The pilot sample was collected in yellow top BD Vacutainer<sup>®</sup> (SST™ II Advance 5 mL tube) with separator gel and was marked for serological testing. It was centrifuged at 7000 rpm for 30 min. Serological testing was performed by chemiluminescence on Abbott Architect Plus i1000SR with Abbott kits for HBsAg, anti-HIV, and anti-HCV. This particular sample tested reactive for HBsAg with S/CO of 1.91, S/CO for HBsAgQ2NC (Negative kit control) being 0.19 and that of HBsAgQ2PC (Positive kit control) being 3.65. Repeat testing from the same Vacutainer was also reactive for HBsAg with S/CO of 2.10. Nucleic acid testing was performed and was found to be nonreactive. We repeated serological testing with a sample from fresh frozen plasma of the same donor unit. It was nonreactive. Cross contamination was ruled out by repeat testing of two serial samples before and after this unit number. The serum showed an unusual appearance on visual inspection after centrifugation. By exclusion, we concluded that the gel probably got partially dislodged into the serum, giving a relatively low reading and false reactive result for HBsAg. This highlights the possibility of inert gel not always being inert, the importance of repeat testing from a different sample in case of low reading, the importance of visual inspection, a need for manufacturers and laboratory personnel to consider such preanalytical variables which, though not much mentioned in literature, can affect test results. These results have a multi-fold impact on the donor or patient's mindset, treatment outcome and/or fate of blood donation. These are definitely preventable if more such guidelines are made available for handy reference in handling such results.</p>","PeriodicalId":42296,"journal":{"name":"Asian Journal of Transfusion Science","volume":"19 2","pages":"342-345"},"PeriodicalIF":0.7000,"publicationDate":"2025-07-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC12614704/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Asian Journal of Transfusion Science","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.4103/ajts.ajts_42_24","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2024/8/22 0:00:00","PubModel":"Epub","JCR":"Q4","JCRName":"HEMATOLOGY","Score":null,"Total":0}
引用次数: 0

Abstract

Preanalytical variables play a key role in the correctness of laboratory test results. We report a false reactive result for hepatitis B surface antigen (HBsAg) on serological testing with a relatively low OD. The pilot sample was collected in yellow top BD Vacutainer® (SST™ II Advance 5 mL tube) with separator gel and was marked for serological testing. It was centrifuged at 7000 rpm for 30 min. Serological testing was performed by chemiluminescence on Abbott Architect Plus i1000SR with Abbott kits for HBsAg, anti-HIV, and anti-HCV. This particular sample tested reactive for HBsAg with S/CO of 1.91, S/CO for HBsAgQ2NC (Negative kit control) being 0.19 and that of HBsAgQ2PC (Positive kit control) being 3.65. Repeat testing from the same Vacutainer was also reactive for HBsAg with S/CO of 2.10. Nucleic acid testing was performed and was found to be nonreactive. We repeated serological testing with a sample from fresh frozen plasma of the same donor unit. It was nonreactive. Cross contamination was ruled out by repeat testing of two serial samples before and after this unit number. The serum showed an unusual appearance on visual inspection after centrifugation. By exclusion, we concluded that the gel probably got partially dislodged into the serum, giving a relatively low reading and false reactive result for HBsAg. This highlights the possibility of inert gel not always being inert, the importance of repeat testing from a different sample in case of low reading, the importance of visual inspection, a need for manufacturers and laboratory personnel to consider such preanalytical variables which, though not much mentioned in literature, can affect test results. These results have a multi-fold impact on the donor or patient's mindset, treatment outcome and/or fate of blood donation. These are definitely preventable if more such guidelines are made available for handy reference in handling such results.

Abstract Image

Abstract Image

Abstract Image

一个假的乙型肝炎表面抗原反应结果,由于从真空容器中移出凝胶。
分析前变量对实验室测试结果的正确性起着关键作用。我们报告了一个假的反应结果乙型肝炎表面抗原(HBsAg)血清学测试与一个相对较低的OD。中试样品采集于带有分离凝胶的黄色顶部BD Vacutainer®(SST™II Advance 5ml管)中,并标记用于血清学检测。以7000转/分离心30分钟。采用化学发光法对Abbott Architect Plus i1000SR进行血清学检测,并用Abbott试剂盒检测HBsAg、anti-HIV和anti-HCV。该样品HBsAg阳性S/CO为1.91,阴性试剂盒对照HBsAgQ2NC S/CO为0.19,阳性试剂盒对照HBsAgQ2PC S/CO为3.65。在同一真空容器中重复检测HBsAg, S/CO为2.10。进行核酸检测,发现无反应。我们用同一供体单位的新鲜冷冻血浆样本重复血清学检测。它是非反应性的。在此单元编号之前和之后对两个系列样品进行重复测试,以排除交叉污染。离心后的血清外观异常。通过排除,我们得出结论,凝胶可能部分移位到血清中,给出相对较低的读数和HBsAg假反应结果。这突出了惰性凝胶不总是惰性的可能性,在读数低的情况下从不同样品重复测试的重要性,目视检查的重要性,制造商和实验室人员需要考虑这些分析前变量,尽管文献中没有提到太多,但会影响测试结果。这些结果对献血者或患者的心态、治疗结果和/或献血的命运有多重影响。如果在处理这些结果时提供更多这样的指导方针,这些绝对是可以预防的。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
CiteScore
0.90
自引率
0.00%
发文量
56
审稿时长
44 weeks
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信
小红书