Samuel M.A. Morais , Andrei B. Karpiouk , Donald J. VanderLaan , Muralidhar Padala , Stanislav Y. Emelianov
{"title":"Assessing myocardial stiffness with transient elastography using catheter-compatible miniature actuator","authors":"Samuel M.A. Morais , Andrei B. Karpiouk , Donald J. VanderLaan , Muralidhar Padala , Stanislav Y. Emelianov","doi":"10.1016/j.ultras.2025.107893","DOIUrl":null,"url":null,"abstract":"<div><div>This study presents a proof-of-concept miniaturized transient elastography (TE) framework for measuring myocardial elasticity during catheter-based cardiac procedures. Recognizing that mechanical properties of myocardial tissue, particularly the shear modulus, offer valuable insight into the development and progression of cardiovascular conditions such as heart failure, we propose a TE system that can be integrated into existing intracardiac catheters. A miniature (2 mm × 2 mm) piezoelectric actuator was used to generate longitudinal shear waves (LSWs) in tissue-mimicking phantoms with varying shear moduli levels and in <em>ex vivo</em> porcine heart tissue. For validation, an ultrasound array transducer was used in this study to visualize the propagation of the LSWs generated by the actuator. Spatiotemporal displacement maps were analyzed to estimate shear wave speeds and corresponding shear moduli, with TE results showing strong agreement with values obtained using conventional acoustic radiation force-based shear wave elasticity imaging (SWEI). The TE and SWEI measurements showed no statistically significant differences. <em>Ex vivo</em> tissue measurements performed in different orientations relative to myocardial fiber direction confirmed the system’s sensitivity to tissue anisotropy. Additionally, the technique successfully distinguished between fresh and fixed heart tissue, detecting a noticeable increase in stiffness due to preservation. These findings support the feasibility of a catheter-integrated TE device as a functional extension of existing clinical workflows, offering quantitative assessment of myocardial elasticity during routine catheterization procedures.</div></div>","PeriodicalId":23522,"journal":{"name":"Ultrasonics","volume":"160 ","pages":"Article 107893"},"PeriodicalIF":4.8000,"publicationDate":"2026-04-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Ultrasonics","FirstCategoryId":"101","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S0041624X25003300","RegionNum":2,"RegionCategory":"物理与天体物理","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2025/11/14 0:00:00","PubModel":"Epub","JCR":"Q1","JCRName":"ACOUSTICS","Score":null,"Total":0}
引用次数: 0
Abstract
This study presents a proof-of-concept miniaturized transient elastography (TE) framework for measuring myocardial elasticity during catheter-based cardiac procedures. Recognizing that mechanical properties of myocardial tissue, particularly the shear modulus, offer valuable insight into the development and progression of cardiovascular conditions such as heart failure, we propose a TE system that can be integrated into existing intracardiac catheters. A miniature (2 mm × 2 mm) piezoelectric actuator was used to generate longitudinal shear waves (LSWs) in tissue-mimicking phantoms with varying shear moduli levels and in ex vivo porcine heart tissue. For validation, an ultrasound array transducer was used in this study to visualize the propagation of the LSWs generated by the actuator. Spatiotemporal displacement maps were analyzed to estimate shear wave speeds and corresponding shear moduli, with TE results showing strong agreement with values obtained using conventional acoustic radiation force-based shear wave elasticity imaging (SWEI). The TE and SWEI measurements showed no statistically significant differences. Ex vivo tissue measurements performed in different orientations relative to myocardial fiber direction confirmed the system’s sensitivity to tissue anisotropy. Additionally, the technique successfully distinguished between fresh and fixed heart tissue, detecting a noticeable increase in stiffness due to preservation. These findings support the feasibility of a catheter-integrated TE device as a functional extension of existing clinical workflows, offering quantitative assessment of myocardial elasticity during routine catheterization procedures.
期刊介绍:
Ultrasonics is the only internationally established journal which covers the entire field of ultrasound research and technology and all its many applications. Ultrasonics contains a variety of sections to keep readers fully informed and up-to-date on the whole spectrum of research and development throughout the world. Ultrasonics publishes papers of exceptional quality and of relevance to both academia and industry. Manuscripts in which ultrasonics is a central issue and not simply an incidental tool or minor issue, are welcomed.
As well as top quality original research papers and review articles by world renowned experts, Ultrasonics also regularly features short communications, a calendar of forthcoming events and special issues dedicated to topical subjects.