A framework checklist for implementing bedside electronic transfusion systems.

IF 1.3 4区 医学 Q3 HEMATOLOGY
Transfusion Medicine Pub Date : 2026-02-01 Epub Date: 2025-11-14 DOI:10.1111/tme.70042
Josephine McCullagh, Suzanne Makki, Kirsty Hancock, Catherine Booth, Louise Bowles, Ollie Djurdjevic, Karen Farrar, Claudio Geraci, Sara Hammond, Helinor Mcaleese, Michael F Murphy, Florence Oyekan, Laura Green
{"title":"A framework checklist for implementing bedside electronic transfusion systems.","authors":"Josephine McCullagh, Suzanne Makki, Kirsty Hancock, Catherine Booth, Louise Bowles, Ollie Djurdjevic, Karen Farrar, Claudio Geraci, Sara Hammond, Helinor Mcaleese, Michael F Murphy, Florence Oyekan, Laura Green","doi":"10.1111/tme.70042","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>Every time a unit of blood is given to a patient, it is essential that all steps in the transfusion pathway are executed correctly to ensure that the right blood is transfused to the right patient. Bedside transfusion checks at the point of sampling for compatibility testing, sample labelling and blood administration are an essential part of the delivery of safe transfusion and avoidance of the wrong blood being given, which can have serious consequences. Implementation of bedside electronic transfusion systems that use barcode matching of patients' wristbands and blood units is now recommended as the best practice to ensure patients' safety in transfusion. However, there is limited information in the literature to guide hospitals on what aspects they should consider when introducing a bedside electronic transfusion system.</p><p><strong>Aims and methods: </strong>This paper aims to support hospitals considering implementing a bedside electronic transfusion system by providing a comprehensive checklist addressing planning, stakeholder coordination, device integration, and compliance with national standards and safety requirements.</p><p><strong>Results: </strong>The checklist is based on the experiences of two NHS Trusts in the UK and aims to provide organisations with a resource to support this change and reduce avoidable delays.</p>","PeriodicalId":23306,"journal":{"name":"Transfusion Medicine","volume":" ","pages":"3-9"},"PeriodicalIF":1.3000,"publicationDate":"2026-02-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC12882753/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Transfusion Medicine","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1111/tme.70042","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2025/11/14 0:00:00","PubModel":"Epub","JCR":"Q3","JCRName":"HEMATOLOGY","Score":null,"Total":0}
引用次数: 0

Abstract

Background: Every time a unit of blood is given to a patient, it is essential that all steps in the transfusion pathway are executed correctly to ensure that the right blood is transfused to the right patient. Bedside transfusion checks at the point of sampling for compatibility testing, sample labelling and blood administration are an essential part of the delivery of safe transfusion and avoidance of the wrong blood being given, which can have serious consequences. Implementation of bedside electronic transfusion systems that use barcode matching of patients' wristbands and blood units is now recommended as the best practice to ensure patients' safety in transfusion. However, there is limited information in the literature to guide hospitals on what aspects they should consider when introducing a bedside electronic transfusion system.

Aims and methods: This paper aims to support hospitals considering implementing a bedside electronic transfusion system by providing a comprehensive checklist addressing planning, stakeholder coordination, device integration, and compliance with national standards and safety requirements.

Results: The checklist is based on the experiences of two NHS Trusts in the UK and aims to provide organisations with a resource to support this change and reduce avoidable delays.

Abstract Image

实施床边电子输液系统的框架检查表。
背景:每次向患者提供一单位血液时,必须正确执行输血途径中的所有步骤,以确保向正确的患者输入正确的血液。在采样点进行床边输血检查,以进行相容性测试、样本标签和血液管理,是提供安全输血和避免输错血的重要组成部分,因为输错血可能产生严重后果。实施床边电子输血系统,使用患者腕带和血液单位的条形码匹配,现在被推荐为确保患者输血安全的最佳做法。然而,在文献中有有限的信息来指导医院在引入床边电子输血系统时应该考虑哪些方面。目的和方法:本文旨在通过提供一份全面的清单,解决计划、利益相关者协调、设备集成以及符合国家标准和安全要求等问题,为考虑实施床边电子输血系统的医院提供支持。结果:检查表是基于英国两个NHS信托的经验,旨在为组织提供资源来支持这一变化,减少可避免的延误。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
Transfusion Medicine
Transfusion Medicine 医学-血液学
CiteScore
2.70
自引率
0.00%
发文量
96
审稿时长
6-12 weeks
期刊介绍: Transfusion Medicine publishes articles on transfusion medicine in its widest context, including blood transfusion practice (blood procurement, pharmaceutical, clinical, scientific, computing and documentary aspects), immunohaematology, immunogenetics, histocompatibility, medico-legal applications, and related molecular biology and biotechnology. In addition to original articles, which may include brief communications and case reports, the journal contains a regular educational section (based on invited reviews and state-of-the-art reports), technical section (including quality assurance and current practice guidelines), leading articles, letters to the editor, occasional historical articles and signed book reviews. Some lectures from Society meetings that are likely to be of general interest to readers of the Journal may be published at the discretion of the Editor and subject to the availability of space in the Journal.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信
小红书