Anne Lejay, Jubran Durbas, Juliette Tabouret, Lena Christ, Nicole Neumann, Salomé Kuntz, Nabil Chakfé
{"title":"Latest vascular devices surveillance news: an overview.","authors":"Anne Lejay, Jubran Durbas, Juliette Tabouret, Lena Christ, Nicole Neumann, Salomé Kuntz, Nabil Chakfé","doi":"10.23736/S0392-9590.25.05472-0","DOIUrl":null,"url":null,"abstract":"<p><p>Since the late 1950s, grafts and endografts have been constructed from a variety of materials and have been designed to be implanted in several different ways. However, despite the level of safety, effectiveness and versatility these devices reached, failures still exist. METHODS: Material surveillance through a dedicated explant analysis program is the cornerstone towards improving knowledge about vascular grafts and endografts behavior in humans. Major lessons learned from explant analysis have already been published few years ago, but this review provides an update by summarizing the recent findings of a dedicated explant analysis program over the past five years. Recent findings include vascular grafts degradation, devices calcifications, mechanisms of endografts failure. Two mechanisms of vascular grafts degradation have been reported: a decrease in the density of the meshing and local ruptures of the polyethylene terephthalate fibers. The degradation occurred preferentially in some grafts zones where the textile was weakened during manufacturing process. Calcification of vascular grafts and endografts have also been reported, and may contribute to device failure, as calcification reduces compliance, increases stiffness and generated a compliance mismatch. Concerning mechanisms of endografts failure, it has been shown that the polymer used in the endobags of the Nellix EndoVascular Aneurysm Sealing (EVAS) System could lose weight and volume upon dehydration. Accordingly, the polymer deteriorated and failed to retain its weight, volume and shape, undergoing fragmentation, explaining the high rate of migration observed with this device. Endoleaks have also been investigated and endograft fabric damages responsible for endoleaks have been demonstrated. This review highlights that despite continuous improvement of vascular and endovascular devices, failure still exists. Accordingly, continuous material surveillance is mandatory in order to provide the latest information on the mechanisms responsible for degradation and implement knowledge concerning the biological and mechanical behavior of grafts and endografts.</p>","PeriodicalId":13709,"journal":{"name":"International Angiology","volume":" ","pages":"143-148"},"PeriodicalIF":1.8000,"publicationDate":"2026-04-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"International Angiology","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.23736/S0392-9590.25.05472-0","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2025/11/13 0:00:00","PubModel":"Epub","JCR":"Q3","JCRName":"PERIPHERAL VASCULAR DISEASE","Score":null,"Total":0}
引用次数: 0
Abstract
Since the late 1950s, grafts and endografts have been constructed from a variety of materials and have been designed to be implanted in several different ways. However, despite the level of safety, effectiveness and versatility these devices reached, failures still exist. METHODS: Material surveillance through a dedicated explant analysis program is the cornerstone towards improving knowledge about vascular grafts and endografts behavior in humans. Major lessons learned from explant analysis have already been published few years ago, but this review provides an update by summarizing the recent findings of a dedicated explant analysis program over the past five years. Recent findings include vascular grafts degradation, devices calcifications, mechanisms of endografts failure. Two mechanisms of vascular grafts degradation have been reported: a decrease in the density of the meshing and local ruptures of the polyethylene terephthalate fibers. The degradation occurred preferentially in some grafts zones where the textile was weakened during manufacturing process. Calcification of vascular grafts and endografts have also been reported, and may contribute to device failure, as calcification reduces compliance, increases stiffness and generated a compliance mismatch. Concerning mechanisms of endografts failure, it has been shown that the polymer used in the endobags of the Nellix EndoVascular Aneurysm Sealing (EVAS) System could lose weight and volume upon dehydration. Accordingly, the polymer deteriorated and failed to retain its weight, volume and shape, undergoing fragmentation, explaining the high rate of migration observed with this device. Endoleaks have also been investigated and endograft fabric damages responsible for endoleaks have been demonstrated. This review highlights that despite continuous improvement of vascular and endovascular devices, failure still exists. Accordingly, continuous material surveillance is mandatory in order to provide the latest information on the mechanisms responsible for degradation and implement knowledge concerning the biological and mechanical behavior of grafts and endografts.
期刊介绍:
International Angiology publishes scientific papers on angiology. Manuscripts may be submitted in the form of editorials, original articles, review articles, special articles, letters to the Editor and guidelines. The journal aims to provide its readers with papers of the highest quality and impact through a process of careful peer review and editorial work. Duties and responsibilities of all the subjects involved in the editorial process are summarized at Publication ethics. Manuscripts are expected to comply with the instructions to authors which conform to the Uniform Requirements for Manuscripts Submitted to Biomedical Editors by the International Committee of Medical Journal Editors (ICMJE).