The impact of physiological and parafunctional posterior occlusal forces on experimental Ti-15Zrsupracrestal dental implant - a finite element analysis.
{"title":"The impact of physiological and parafunctional posterior occlusal forces on experimental Ti-15Zrsupracrestal dental implant - a finite element analysis.","authors":"Brigitta Bokor, Adriana Objelean, Simion Bran, Radu Septimiu Campian, Cristian Vilău","doi":"10.15386/mpr-2930","DOIUrl":null,"url":null,"abstract":"<p><strong>Aim of the study: </strong>This study aims to evaluate and compare the stress distribution patterns of two experimental tissue-level, convergent collar implants (one made of Ti-6Al-4V (control) and the other of Roxolid-based (Ti-15Zr) material) using 3D finite element analysis (FEA) under various simulated masticatory conditions.</p><p><strong>Methods: </strong>A 3D finite element model replicating a tissue-level implant with convergent neck design was developed in ANSYS software, incorporating both cortical and trabecular bone geometry. Implants made of Ti-6Al-4V-Grade 5 and Roxolide-type-Ti-15Zr alloy were simulated under axial (0°) and oblique (45° angle) loading forces (50 N, 200 N, 300 N, and 400 N). The von Mises equivalent stress distribution was calculated to assess the biomechanical performance.</p><p><strong>Results: </strong>Under masticatory forces simulation, titanium-alloy implants exhibited maximum stress values (400 N) of 260.38 MPa under axial load and 536.2 MPa under oblique load. Ti-15Zr implants exhibited a slightly lower peak stress of 506.95 MPa under a load of 400 N at a 45° inclination and 240.81 N under axial load. Based on 3D finite analysis, the stress distribution maps showed higher concentration in the implant-abutment connection and the cervical region, particularly under oblique loading.</p><p><strong>Conclusions: </strong>Although titanium implants exhibited higher stress limits, Ti-15Zr implants showed biomechanical stability under oblique simulated forces. Ti-15Zr implants exhibited a more uniform stress distribution with a reduced peak concentration.</p>","PeriodicalId":18438,"journal":{"name":"Medicine and Pharmacy Reports","volume":"98 4","pages":"511-521"},"PeriodicalIF":0.0000,"publicationDate":"2025-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC12600071/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Medicine and Pharmacy Reports","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.15386/mpr-2930","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2024/10/30 0:00:00","PubModel":"Epub","JCR":"Q2","JCRName":"Medicine","Score":null,"Total":0}
引用次数: 0
Abstract
Aim of the study: This study aims to evaluate and compare the stress distribution patterns of two experimental tissue-level, convergent collar implants (one made of Ti-6Al-4V (control) and the other of Roxolid-based (Ti-15Zr) material) using 3D finite element analysis (FEA) under various simulated masticatory conditions.
Methods: A 3D finite element model replicating a tissue-level implant with convergent neck design was developed in ANSYS software, incorporating both cortical and trabecular bone geometry. Implants made of Ti-6Al-4V-Grade 5 and Roxolide-type-Ti-15Zr alloy were simulated under axial (0°) and oblique (45° angle) loading forces (50 N, 200 N, 300 N, and 400 N). The von Mises equivalent stress distribution was calculated to assess the biomechanical performance.
Results: Under masticatory forces simulation, titanium-alloy implants exhibited maximum stress values (400 N) of 260.38 MPa under axial load and 536.2 MPa under oblique load. Ti-15Zr implants exhibited a slightly lower peak stress of 506.95 MPa under a load of 400 N at a 45° inclination and 240.81 N under axial load. Based on 3D finite analysis, the stress distribution maps showed higher concentration in the implant-abutment connection and the cervical region, particularly under oblique loading.
Conclusions: Although titanium implants exhibited higher stress limits, Ti-15Zr implants showed biomechanical stability under oblique simulated forces. Ti-15Zr implants exhibited a more uniform stress distribution with a reduced peak concentration.