The impact of physiological and parafunctional posterior occlusal forces on experimental Ti-15Zrsupracrestal dental implant - a finite element analysis.

Q2 Medicine
Medicine and Pharmacy Reports Pub Date : 2025-10-01 Epub Date: 2024-10-30 DOI:10.15386/mpr-2930
Brigitta Bokor, Adriana Objelean, Simion Bran, Radu Septimiu Campian, Cristian Vilău
{"title":"The impact of physiological and parafunctional posterior occlusal forces on experimental Ti-15Zrsupracrestal dental implant - a finite element analysis.","authors":"Brigitta Bokor, Adriana Objelean, Simion Bran, Radu Septimiu Campian, Cristian Vilău","doi":"10.15386/mpr-2930","DOIUrl":null,"url":null,"abstract":"<p><strong>Aim of the study: </strong>This study aims to evaluate and compare the stress distribution patterns of two experimental tissue-level, convergent collar implants (one made of Ti-6Al-4V (control) and the other of Roxolid-based (Ti-15Zr) material) using 3D finite element analysis (FEA) under various simulated masticatory conditions.</p><p><strong>Methods: </strong>A 3D finite element model replicating a tissue-level implant with convergent neck design was developed in ANSYS software, incorporating both cortical and trabecular bone geometry. Implants made of Ti-6Al-4V-Grade 5 and Roxolide-type-Ti-15Zr alloy were simulated under axial (0°) and oblique (45° angle) loading forces (50 N, 200 N, 300 N, and 400 N). The von Mises equivalent stress distribution was calculated to assess the biomechanical performance.</p><p><strong>Results: </strong>Under masticatory forces simulation, titanium-alloy implants exhibited maximum stress values (400 N) of 260.38 MPa under axial load and 536.2 MPa under oblique load. Ti-15Zr implants exhibited a slightly lower peak stress of 506.95 MPa under a load of 400 N at a 45° inclination and 240.81 N under axial load. Based on 3D finite analysis, the stress distribution maps showed higher concentration in the implant-abutment connection and the cervical region, particularly under oblique loading.</p><p><strong>Conclusions: </strong>Although titanium implants exhibited higher stress limits, Ti-15Zr implants showed biomechanical stability under oblique simulated forces. Ti-15Zr implants exhibited a more uniform stress distribution with a reduced peak concentration.</p>","PeriodicalId":18438,"journal":{"name":"Medicine and Pharmacy Reports","volume":"98 4","pages":"511-521"},"PeriodicalIF":0.0000,"publicationDate":"2025-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC12600071/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Medicine and Pharmacy Reports","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.15386/mpr-2930","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2024/10/30 0:00:00","PubModel":"Epub","JCR":"Q2","JCRName":"Medicine","Score":null,"Total":0}
引用次数: 0

Abstract

Aim of the study: This study aims to evaluate and compare the stress distribution patterns of two experimental tissue-level, convergent collar implants (one made of Ti-6Al-4V (control) and the other of Roxolid-based (Ti-15Zr) material) using 3D finite element analysis (FEA) under various simulated masticatory conditions.

Methods: A 3D finite element model replicating a tissue-level implant with convergent neck design was developed in ANSYS software, incorporating both cortical and trabecular bone geometry. Implants made of Ti-6Al-4V-Grade 5 and Roxolide-type-Ti-15Zr alloy were simulated under axial (0°) and oblique (45° angle) loading forces (50 N, 200 N, 300 N, and 400 N). The von Mises equivalent stress distribution was calculated to assess the biomechanical performance.

Results: Under masticatory forces simulation, titanium-alloy implants exhibited maximum stress values (400 N) of 260.38 MPa under axial load and 536.2 MPa under oblique load. Ti-15Zr implants exhibited a slightly lower peak stress of 506.95 MPa under a load of 400 N at a 45° inclination and 240.81 N under axial load. Based on 3D finite analysis, the stress distribution maps showed higher concentration in the implant-abutment connection and the cervical region, particularly under oblique loading.

Conclusions: Although titanium implants exhibited higher stress limits, Ti-15Zr implants showed biomechanical stability under oblique simulated forces. Ti-15Zr implants exhibited a more uniform stress distribution with a reduced peak concentration.

Abstract Image

Abstract Image

Abstract Image

生理和副功能后咬合力对实验性ti - 15zr牙种植体的影响-有限元分析。
研究目的:本研究旨在利用三维有限元分析(FEA)来评估和比较两种实验性组织级、会聚型种植体(一种由Ti-6Al-4V(对照)制成,另一种由roxolid (Ti-15Zr)材料制成)在各种模拟咀嚼条件下的应力分布模式。方法:在ANSYS软件中建立一个三维有限元模型,复制具有会聚颈设计的组织级种植体,并结合皮质骨和骨小梁的几何形状。采用Ti-6Al-4V-Grade 5和roxolide型ti - 15zr合金制备种植体,模拟了轴向(0°)和斜向(45°)加载力(50 N、200 N、300 N和400 N)。计算von Mises等效应力分布,评价生物力学性能。结果:在咀嚼力模拟下,钛合金种植体在轴向载荷下的最大应力值(400 N)为260.38 MPa,在斜向载荷下的最大应力值为536.2 MPa。Ti-15Zr钎料在45°倾角400 N载荷下峰值应力为506.95 MPa,轴向载荷为240.81 N时峰值应力略低。基于三维有限元分析,应力分布图显示种植体-基台连接处和颈椎区域的应力集中度较高,特别是在斜载荷下。结论:虽然钛种植体具有较高的应力极限,但Ti-15Zr种植体在斜向模拟力作用下具有生物力学稳定性。随着峰值浓度的降低,Ti-15Zr植入物的应力分布更加均匀。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
Medicine and Pharmacy Reports
Medicine and Pharmacy Reports Medicine-Medicine (all)
CiteScore
3.10
自引率
0.00%
发文量
63
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信
小红书