Impact of pre-analytical variables - temperature, agitation, storage duration, and blood-to-anticoagulant ratio - on complete blood count test reliability.

Q2 Medicine
Medicine and Pharmacy Reports Pub Date : 2025-10-01 Epub Date: 2024-10-30 DOI:10.15386/mpr-2880
Malek A Al-Najdawi, Abdulfattah Salah Fararjeh, Moayad Khataibeh
{"title":"Impact of pre-analytical variables - temperature, agitation, storage duration, and blood-to-anticoagulant ratio - on complete blood count test reliability.","authors":"Malek A Al-Najdawi, Abdulfattah Salah Fararjeh, Moayad Khataibeh","doi":"10.15386/mpr-2880","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>The complete blood count is a widely used medical laboratory test that is essential for both diagnosis and treatment decisions. While pre-analytic factors, such as storage temperature, transport conditions, blood volume anticoagulant ratio, and testing delay, might impact the accuracy of the results, the degree of this influence requires further quantification. In the present study, we aim to look more closely at these factors and how they affect complete blood count test readings.</p><p><strong>Methods: </strong>This study evaluates the effects of temperature, agitation, storage duration, and blood volume anticoagulant ratio on complete blood count reliability using a repeated-measures factorial design. A total of 224 CBC runs were performed on the samples of eight participants. Samples were tested at baseline T0 and again at 4, 12, and 24 hours after storage at either room temperature (22°C) or refrigeration (4°C), with and without agitation, and at both optimal (2 mL) and suboptimal (1 mL) blood volumes.</p><p><strong>Results: </strong>The duration of storage was the main factor determining CBC accuracy. After 12 h, WBC counts decreased significantly (p < 0.001, η<sup>2</sup> = 0.129). Platelet counts also declined (p < 0.001, η<sup>2</sup> = 0.73), with greater loss at 4°C (-8.1%) than at 22°C (-5.2%) by 24 h. MCV remained stable at 4°C but increased at 22°C (p < 0.001). Hemoglobin decreased at 22°C (-2.3%, p < 0.05), and RBC counts dropped modestly (-2.2%, p < 0.05). MPV showed only a minor change (p > 0.05). Neither agitation nor suboptimal blood volume had significant effects (p > 0.05).</p><p><strong>Conclusion: </strong>Specimens should ideally be tested within 12 hours or stored at 4°C to prevent degradation of the test variables, particularly white blood cell counts and platelet counts. The findings suggest that routine handling and transport conditions are appropriate, as agitation during transport and a decreased blood volume-to-anticoagulant ratio appear to have negligible effects. Incorporating measurement uncertainty benchmarks improves the distinction between genuine sample deterioration and assay variability, thereby enhancing diagnostic accuracy.</p>","PeriodicalId":18438,"journal":{"name":"Medicine and Pharmacy Reports","volume":"98 4","pages":"452-460"},"PeriodicalIF":0.0000,"publicationDate":"2025-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC12600060/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Medicine and Pharmacy Reports","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.15386/mpr-2880","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2024/10/30 0:00:00","PubModel":"Epub","JCR":"Q2","JCRName":"Medicine","Score":null,"Total":0}
引用次数: 0

Abstract

Background: The complete blood count is a widely used medical laboratory test that is essential for both diagnosis and treatment decisions. While pre-analytic factors, such as storage temperature, transport conditions, blood volume anticoagulant ratio, and testing delay, might impact the accuracy of the results, the degree of this influence requires further quantification. In the present study, we aim to look more closely at these factors and how they affect complete blood count test readings.

Methods: This study evaluates the effects of temperature, agitation, storage duration, and blood volume anticoagulant ratio on complete blood count reliability using a repeated-measures factorial design. A total of 224 CBC runs were performed on the samples of eight participants. Samples were tested at baseline T0 and again at 4, 12, and 24 hours after storage at either room temperature (22°C) or refrigeration (4°C), with and without agitation, and at both optimal (2 mL) and suboptimal (1 mL) blood volumes.

Results: The duration of storage was the main factor determining CBC accuracy. After 12 h, WBC counts decreased significantly (p < 0.001, η2 = 0.129). Platelet counts also declined (p < 0.001, η2 = 0.73), with greater loss at 4°C (-8.1%) than at 22°C (-5.2%) by 24 h. MCV remained stable at 4°C but increased at 22°C (p < 0.001). Hemoglobin decreased at 22°C (-2.3%, p < 0.05), and RBC counts dropped modestly (-2.2%, p < 0.05). MPV showed only a minor change (p > 0.05). Neither agitation nor suboptimal blood volume had significant effects (p > 0.05).

Conclusion: Specimens should ideally be tested within 12 hours or stored at 4°C to prevent degradation of the test variables, particularly white blood cell counts and platelet counts. The findings suggest that routine handling and transport conditions are appropriate, as agitation during transport and a decreased blood volume-to-anticoagulant ratio appear to have negligible effects. Incorporating measurement uncertainty benchmarks improves the distinction between genuine sample deterioration and assay variability, thereby enhancing diagnostic accuracy.

Abstract Image

Abstract Image

Abstract Image

分析前变量——温度、搅拌、储存时间和血液与抗凝剂比——对全血细胞计数测试可靠性的影响。
背景:全血细胞计数是一种广泛使用的医学实验室检查,对诊断和治疗决策都是必不可少的。虽然分析前因素,如储存温度、运输条件、血容量抗凝比和检测延迟,可能会影响结果的准确性,但这种影响的程度需要进一步量化。在目前的研究中,我们的目标是更密切地关注这些因素以及它们如何影响全血细胞计数测试读数。方法:本研究使用重复测量因子设计评估温度、搅拌、储存时间和血容量抗凝比对全血细胞计数可靠性的影响。总共对8名参与者的样本进行了224次CBC测试。在室温(22°C)或冷藏(4°C)保存后4、12和24小时,以及在最佳(2ml)和次优(1ml)血容量下,对样品在基线T0和再次进行检测。结果:保存时间是影响CBC准确性的主要因素。12 h后WBC计数明显下降(p < 0.001, η2 = 0.129)。血小板计数也下降(p < 0.001, η2 = 0.73), 4°C时血小板计数的下降(-8.1%)比22°C时的下降(-5.2%)更大(24小时)。MCV在4°C时保持稳定,但在22°C时增加(p < 0.001)。22°C时血红蛋白下降(-2.3%,p < 0.05), RBC计数轻微下降(-2.2%,p < 0.05)。MPV变化较小(p < 0.05)。躁动和次优血容量均无显著影响(p < 0.05)。结论:理想情况下,标本应在12小时内检测或在4°C保存,以防止检测变量的降解,特别是白细胞计数和血小板计数。研究结果表明,常规处理和运输条件是合适的,因为运输过程中的躁动和血容量与抗凝剂比的降低似乎可以忽略不计。结合测量不确定度基准提高了真正的样品变质和分析变异性之间的区别,从而提高了诊断的准确性。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
Medicine and Pharmacy Reports
Medicine and Pharmacy Reports Medicine-Medicine (all)
CiteScore
3.10
自引率
0.00%
发文量
63
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信
小红书