A. Khodaei , F. Moradi , H.T. Zubair , S.A. Ibrahim , H.A. Abdul-Rashid
{"title":"Monte Carlo investigation of Ge-doped silica fiber detectors for precision small field dosimetry","authors":"A. Khodaei , F. Moradi , H.T. Zubair , S.A. Ibrahim , H.A. Abdul-Rashid","doi":"10.1016/j.radmeas.2025.107552","DOIUrl":null,"url":null,"abstract":"<div><div>Accurate dosimetry in small radiation fields remains a critical challenge in modern radiotherapy due to high dose gradients and limited detector spatial resolution. This study investigates the dosimetric performance of Ge-doped silica fiber radioluminescence (RL) detectors for small field measurements through Monte Carlo simulations using the TOPAS tool. Reference data from IAEA database were utilized for implementation of small radiation fields and validation, by comparing experimental beam profile and depth dose measurements for various field sizes. Quality dependence factors (QDFs) were calculated based on the formalism of the IAEA-AAPM working group, considering a Varian Clinac iX linear accelerator with a 10 × 10 cm<sup>2</sup> reference field and various small fields of 0.5 × 0.5 cm<sup>2</sup>, 1 × 1 cm<sup>2</sup>, 2 × 2 cm<sup>2</sup> and 4 × 4 cm<sup>2</sup>. The study explored different fiber detector diameters from 125 μm to 2 mm to optimize spatial resolution for small field dosimetry. Simulated electron spectra in various situations were analyzed in both water and fiber volumes to understand reasons behind detector response variations. Notably, the detector diameter significantly influenced quality dependence, with competing effects between energy dependence and a field size dependent spectral discrepancy leading to an optimal balance at a 0.5 mm fiber diameter. Calculated QDFs aligned well within the range reported for other detector types, supporting the applicability of Ge-doped silica fiber RL detectors for precise dose measurements in small radiation fields, offering a potential alternative for advanced radiotherapy applications.</div></div>","PeriodicalId":21055,"journal":{"name":"Radiation Measurements","volume":"190 ","pages":"Article 107552"},"PeriodicalIF":1.8000,"publicationDate":"2026-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Radiation Measurements","FirstCategoryId":"101","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S1350448725001817","RegionNum":3,"RegionCategory":"物理与天体物理","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2025/10/31 0:00:00","PubModel":"Epub","JCR":"Q2","JCRName":"NUCLEAR SCIENCE & TECHNOLOGY","Score":null,"Total":0}
引用次数: 0
Abstract
Accurate dosimetry in small radiation fields remains a critical challenge in modern radiotherapy due to high dose gradients and limited detector spatial resolution. This study investigates the dosimetric performance of Ge-doped silica fiber radioluminescence (RL) detectors for small field measurements through Monte Carlo simulations using the TOPAS tool. Reference data from IAEA database were utilized for implementation of small radiation fields and validation, by comparing experimental beam profile and depth dose measurements for various field sizes. Quality dependence factors (QDFs) were calculated based on the formalism of the IAEA-AAPM working group, considering a Varian Clinac iX linear accelerator with a 10 × 10 cm2 reference field and various small fields of 0.5 × 0.5 cm2, 1 × 1 cm2, 2 × 2 cm2 and 4 × 4 cm2. The study explored different fiber detector diameters from 125 μm to 2 mm to optimize spatial resolution for small field dosimetry. Simulated electron spectra in various situations were analyzed in both water and fiber volumes to understand reasons behind detector response variations. Notably, the detector diameter significantly influenced quality dependence, with competing effects between energy dependence and a field size dependent spectral discrepancy leading to an optimal balance at a 0.5 mm fiber diameter. Calculated QDFs aligned well within the range reported for other detector types, supporting the applicability of Ge-doped silica fiber RL detectors for precise dose measurements in small radiation fields, offering a potential alternative for advanced radiotherapy applications.
期刊介绍:
The journal seeks to publish papers that present advances in the following areas: spontaneous and stimulated luminescence (including scintillating materials, thermoluminescence, and optically stimulated luminescence); electron spin resonance of natural and synthetic materials; the physics, design and performance of radiation measurements (including computational modelling such as electronic transport simulations); the novel basic aspects of radiation measurement in medical physics. Studies of energy-transfer phenomena, track physics and microdosimetry are also of interest to the journal.
Applications relevant to the journal, particularly where they present novel detection techniques, novel analytical approaches or novel materials, include: personal dosimetry (including dosimetric quantities, active/electronic and passive monitoring techniques for photon, neutron and charged-particle exposures); environmental dosimetry (including methodological advances and predictive models related to radon, but generally excluding local survey results of radon where the main aim is to establish the radiation risk to populations); cosmic and high-energy radiation measurements (including dosimetry, space radiation effects, and single event upsets); dosimetry-based archaeological and Quaternary dating; dosimetry-based approaches to thermochronometry; accident and retrospective dosimetry (including activation detectors), and dosimetry and measurements related to medical applications.